-
XIPE: the X-ray Imaging Polarimetry Explorer
Authors:
Paolo Soffitta,
Xavier Barcons,
Ronaldo Bellazzini,
João Braga,
Enrico Costa,
George W. Fraser,
Szymon Gburek,
Juhani Huovelin,
Giorgio Matt,
Mark Pearce,
Juri Poutanen,
Victor Reglero,
Andrea Santangelo,
Rashid A. Sunyaev,
Gianpiero Tagliaferri,
Martin Weisskopf,
Roberto Aloisio,
Elena Amato,
Primo Attiná,
Magnus Axelsson,
Luca Baldini,
Stefano Basso,
Stefano Bianchi,
Pasquale Blasi,
Johan Bregeon
, et al. (74 additional authors not shown)
Abstract:
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and wh…
▽ More
X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017 but not selected. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus and two additional GPDs filled with pressurized Ar-DME facing the sun. The Minimum Detectable Polarization is 14 % at 1 mCrab in 10E5 s (2-10 keV) and 0.6 % for an X10 class flare. The Half Energy Width, measured at PANTER X-ray test facility (MPE, Germany) with JET-X optics is 24 arcsec. XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil).
△ Less
Submitted 26 September, 2013;
originally announced September 2013.
-
Imaging with the invisible light
Authors:
R. Bellazzini,
G. Spandre,
A. Brez,
M. Minuti,
L. Baldini,
L. Latronico,
M. M. Massai,
N. Omodei,
M. Pesce-Rollins,
C Sgró,
M. Razzano,
M. Pinchera,
J. Bregeon,
M. Kuss,
A. Braem
Abstract:
We describe a UV photo-detector with single photon(electron) counting and imaging capability. It is based on a CsI photocathode, a GEM charge multiplier and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron pitch. The single photoelectron produced by the absorption of a UV photon is drifted to and multiplied inside a single GEM hole. The coordinates of the GEM avalanche are…
▽ More
We describe a UV photo-detector with single photon(electron) counting and imaging capability. It is based on a CsI photocathode, a GEM charge multiplier and a self triggering CMOS analog pixel chip with 105k pixels at 50 micron pitch. The single photoelectron produced by the absorption of a UV photon is drifted to and multiplied inside a single GEM hole. The coordinates of the GEM avalanche are reconstructed with high accuracy (4 micron rms) by the pixel chip. As a result the map of the GEM holes, arranged on a triangular pattern at 50micron pitch, is finely imaged.
△ Less
Submitted 20 March, 2007; v1 submitted 19 March, 2007;
originally announced March 2007.
-
A Sealed Gas Pixel Detector for X-ray Astronomy
Authors:
R. Bellazzini,
G. Spandre,
M. Minuti,
L. Baldini,
A. Brez,
L. Latronico,
N. Omodei,
M. Razzano,
M. M. Massai,
M. Pinchera,
M. Pesce-Rollins,
C. Sgro,
E. Costa,
P. Soffitta,
H. Sipila,
E. Lempinen
Abstract:
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The instrument brings high sensitivity to X-ray polarimetry, which is the last unexplored field of X-ray astronomy. It derives the polarization information from the…
▽ More
We report on the results of a new, sealed, Gas Pixel Detector. The very compact design and the absence of the gas flow system, make this detector substantially ready for use as focal plane detector for future X-ray space telescopes. The instrument brings high sensitivity to X-ray polarimetry, which is the last unexplored field of X-ray astronomy. It derives the polarization information from the track of the photoelectrons that are imaged by a high gain (>1000), fine pitch GEM that matches the pitch of a pixel ASIC which is the collecting anode of the GPD (105k, 50 micron wide, hexagonal cells). The device is able to simultaneously perform good imaging (50-60 micron), moderate spectroscopy (~15% at 6 keV) as well as fast, high rate timing in the 1-10keV range. Moreover, being truly 2D, it is non dispersive and does not require any rotation. The great improvement of sensitivity, at least two orders of magnitude with respect to traditional polarimeters (based on Bragg crystals or Thomson scattering), will allow the direct exploration of the most dramatic objects of the X-ray sky. At the focus of the large mirror area of the XEUS telescope it will be decisive in reaching many of the scientific goals of the mission. With integration times of the order of one day, polarimetry of Active Galactic Nuclei at the per cent level will be possible, making for a real breakthrough in high energy astrophysics.
△ Less
Submitted 20 November, 2006; v1 submitted 16 November, 2006;
originally announced November 2006.
-
POLARIX: a small mission of x-ray polarimetry
Authors:
Enrico Costa,
Ronaldo Bellazzini,
Paolo Soffitta,
Fabio Muleri,
Marco Feroci,
Massimo Frutti,
Marcello Mastropietro,
Luigi Pacciani,
Alda Rubini,
Ennio Morelli,
Luca Baldini,
Francesco Bitti,
Alessandro Brez,
Francesco Cavalca,
Luca Latronico,
Marco Maria Massai,
Nicola Omodei,
Michele Pinchera,
Carmelo Sgro',
Gloria Spandre,
Giorgio Matt,
Giuseppe Cesare Perola,
Guido Chincarini,
Oberto Citterio,
Gianpiero Tagliaferri
, et al. (2 additional authors not shown)
Abstract:
X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX…
▽ More
X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX has been conceived as such a pathfinder. It is a Small Satellite based on the optics of JET-X. Two telescopes are available in flight configuration and three more can be easily produced starting from the available superpolished mandrels. We show the capabilities of such a cluster of telescopes each equipped with a focal plane photoelectric polarimeter and discuss a few alternative solutions.
△ Less
Submitted 20 September, 2006;
originally announced September 2006.
-
An X-ray polarimeter for hard X-ray optics
Authors:
Fabio Muleri,
Ronaldo Bellazzini,
Enrico Costa,
Paolo Soffitta,
Francesco Lazzarotto,
Marco Feroci,
Luigi Pacciani,
Alda Rubini,
Ennio Morelli,
Luca Baldini,
Francesco Bitti,
Alessandro Brez,
Francesco Cavalca,
Luca Latronico,
Marco Maria Massai,
Nicola Omodei,
Michele Pinchera,
Carmelo Sgro',
Gloria Spandre,
Giorgio Matt,
Giuseppe Cesare Perola,
Oberto Citterio,
Giovanni Pareschi,
Vincenzo Cotroneo,
Daniele Spiga
, et al. (1 additional authors not shown)
Abstract:
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer o…
▽ More
Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer optics, galatic and extragalactic X-ray polarimetry can be done up till 30 keV.
△ Less
Submitted 20 September, 2006;
originally announced September 2006.
-
A photoelectric polarimeter for XEUS: a new window in x-ray sky
Authors:
Ronaldo Bellazzini,
Luca Baldini,
Francesco Bitti,
Alessandro Brez,
Francesco Cavalca,
Luca Latronico,
Marco Maria Massai,
Nicola Omodei,
Michele Pinchera,
Carmelo Sgro',
Gloria Spandre,
Enrico Costa,
Paolo Soffitta,
Giuseppe Di Persio,
Marco Feroci,
Fabio Muleri,
Luigi Pacciani,
Alda Rubini,
Ennio Morelli,
Giorgio Matt,
Giuseppe Cesare Perola
Abstract:
XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of Optical Astronomy in terms of collecting areas. It will be based on two satellites, locked on a formation flight, one with the optics, one with the focal plane. The present design of the focal plane foresees, as an auxiliary instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We show how such a…
▽ More
XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of Optical Astronomy in terms of collecting areas. It will be based on two satellites, locked on a formation flight, one with the optics, one with the focal plane. The present design of the focal plane foresees, as an auxiliary instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We show how such a device is capable to solve open problems on many classes of High Energy Astrophysics objects and to use X-ray sources as a laboratory for a substantial progress on Fundamental Physics.
△ Less
Submitted 20 September, 2006;
originally announced September 2006.
-
Direct reading of charge multipliers with a self-triggering CMOS analog chip with 105k pixels at 50 micron pitch
Authors:
R. Bellazzini,
G. Spandre,
M. Minuti,
L. Baldini,
A. Brez,
F. Cavalca,
L. Latronico,
N. Omodei,
M. M. Massai,
C. Sgro,
E. Costa,
P. Soffitta F. Krummenacher,
R. DeOliveira
Abstract:
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel…
▽ More
We report on a large active area (15x15mm2), high channel density (470 pixels/mm2), self-triggering CMOS analog chip that we have developed as pixelized charge collecting electrode of a Micropattern Gas Detector. This device, which represents a big step forward both in terms of size and performance, is the last version of three generations of custom ASICs of increasing complexity. The CMOS pixel array has the top metal layer patterned in a matrix of 105600 hexagonal pixels at 50 micron pitch. Each pixel is directly connected to the underneath full electronics chain which has been realized in the remaining five metal and two poly-silicon layers of a 0.18 micron VLSI technology. The chip has customizable self-triggering capability and includes a signal pre-processing function for the automatic localization of the event coordinates. In this way it is possible to reduce significantly the readout time and the data volume by limiting the signal output only to those pixels belonging to the region of interest. The very small pixel area and the use of a deep sub-micron CMOS technology has brought the noise down to 50 electrons ENC. Results from in depth tests of this device when coupled to a fine pitch (50 micron on a triangular pattern) Gas Electron Multiplier are presented. The matching of readout and gas amplification pitch allows to get optimal results. The application of this detector for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation when working with two gas mixtures and two different photon energies is shown. Results from a full MonteCarlo simulation for several galactic and extragalactic atronomical sources are also reported.
△ Less
Submitted 26 April, 2006; v1 submitted 14 April, 2006;
originally announced April 2006.
-
Opening a New Window to Fundamental Physics and Astrophysics: X-ray Polarimetry
Authors:
E. Costa,
R. Bellazzini,
P. Soffitta,
G. di Persio,
M. Feroci,
E. Morelli,
F. Muleri,
L. Pacciani,
A. Rubini,
L. Baldini,
F. Bitti,
A. Brez,
F. Cavalca,
L. Latronico,
M. M. Massai,
N. Omodei,
C. Sgro',
G. Spandre,
G. Matt,
G. C. Perola,
A. Santangelo,
A. Celotti,
D. Barret,
O. Vilhu,
L. Piro
, et al. (3 additional authors not shown)
Abstract:
An extensive theoretical literature predicts that X-ray Polarimetry can directly determine relevant physical and geometrical parameters of astrophysical sources, and discriminate between models further than allowed by spectral and timing data only. X-ray Polarimetry can also provide tests of Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New Generation X-ray telescop…
▽ More
An extensive theoretical literature predicts that X-ray Polarimetry can directly determine relevant physical and geometrical parameters of astrophysical sources, and discriminate between models further than allowed by spectral and timing data only. X-ray Polarimetry can also provide tests of Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New Generation X-ray telescope could open this new window in the High Energy Sky.
△ Less
Submitted 15 March, 2006;
originally announced March 2006.
-
Gas Pixel Detectors for X-ray Polarimetry applications
Authors:
R. Bellazzini,
F. Angelini,
L. Baldini,
F. Bitti,
A. Brez,
F. Cavalca,
M. Del Prete,
M. Kuss,
L. Latronico,
N. Omodei,
M. Pinchera,
M. M. Massai,
M. Minuti,
M. Razzano,
C. Sgro,
G. Spandre,
A. Tenze,
E. Costa,
P. Soffitta
Abstract:
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting…
▽ More
We discuss a new class of Micro Pattern Gas Detectors, the Gas Pixel Detector (GPD), in which a complete integration between the gas amplification structure and the read-out electronics has been reached. An Application-Specific Integrated Circuit (ASIC) built in deep sub-micron technology has been developed to realize a monolithic device that is, at the same time, the pixelized charge collecting electrode and the amplifying, shaping and charge measuring front-end electronics. The CMOS chip has the top metal layer patterned in a matrix of 80 micron pitch hexagonal pixels, each of them directly connected to the underneath electronics chain which has been realized in the remaining five layers of the 0.35 micron VLSI technology. Results from tests of a first prototype of such detector with 2k pixels and a full scale version with 22k pixels are presented. The application of this device for Astronomical X-Ray Polarimetry is discussed. The experimental detector response to polarized and unpolarized X-ray radiation is shown. Results from a full MonteCarlo simulation for two astronomical sources, the Crab Nebula and the Hercules X1, are also reported.
△ Less
Submitted 8 February, 2006; v1 submitted 9 December, 2005;
originally announced December 2005.
-
Reading a GEM with a VLSI pixel ASIC used as a direct charge collecting anode
Authors:
R. Bellazzini,
F. Angelini,
L. Baldini,
F. Bitti,
A. Brez,
L. Latronico,
M. M. Massai,
M. Minuti,
N. Omodei,
M. Razzano,
C. Sgro,
G. Spandre,
E. Costa,
P. Soffitta
Abstract:
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 micron pitch, directly used as the charge colle…
▽ More
In MicroPattern Gas Detectors (MPGD) when the pixel size is below 100 micron and the number of pixels is large (above 1000) it is virtually impossible to use the conventional PCB read-out approach to bring the signal charge from the individual pixel to the external electronics chain. For this reason a custom CMOS array of 2101 active pixels with 80 micron pitch, directly used as the charge collecting anode of a GEM amplifying structure, has been developed and built. Each charge collecting pad, hexagonally shaped, realized using the top metal layer of a deep submicron VLSI technology is individually connected to a full electronics chain (pre-amplifier, shaping-amplifier, sample and hold, multiplexer) which is built immediately below it by using the remaining five active layers. The GEM and the drift electrode window are assembled directly over the chip so the ASIC itself becomes the pixelized anode of a MicroPattern Gas Detector. With this approach, for the first time, gas detectors have reached the level of integration and resolution typical of solid state pixel detectors. Results from the first tests of this new read-out concept are presented. An Astronomical X-Ray Polarimetry application is also discussed.
△ Less
Submitted 1 March, 2004;
originally announced March 2004.