-
First Principle Simulator of a Stochastically Varying Image Plane for Photon-Counting High Contrast Applications
Authors:
R. H. Dodkins,
K. Davis,
B. Lewis,
S. Mahashabde,
B. A. Mazin,
I. A. Lipartito,
N. Fruitwala,
K. O'Brien,
N. Thatte
Abstract:
Optical and near-infrared Microwave Kinetic Inductance Detectors, or MKIDs, are low-temperature detectors with inherent spectral resolution that are able to instantly register individual photons with potentially no false counts or readout noise. These properties make MKIDs transformative for exoplanet direct imaging by enabling photon-statistics-based planet-discrimination techniques as well as pe…
▽ More
Optical and near-infrared Microwave Kinetic Inductance Detectors, or MKIDs, are low-temperature detectors with inherent spectral resolution that are able to instantly register individual photons with potentially no false counts or readout noise. These properties make MKIDs transformative for exoplanet direct imaging by enabling photon-statistics-based planet-discrimination techniques as well as performing conventional noise-subtraction techniques on shorter timescales. These detectors are in the process of rapid development, and as such, the full extent of their performance enhancing potential has not yet be quantified.
MKID Exoplanet Direct Imaging Simulator, or MEDIS, is a general-purpose end-to-end numerical simulator for high-contrast observations with MKIDs. The simulator exploits current optical propagation libraries and augments them with a new MKIDs simulation module to provide a pragmatic model of many of the degradation effects present during the detection process. We use MEDIS to demonstrate how changes in various MKID properties affect the contrast-separation performance when conventional differential imaging techniques are applied to low-flux, short duration observations.
We show that to improve performance at close separations will require increasing the maximum count rate or pixel sampling when there is high residual flux after the coronagraph. We predict that taking pixel yield from the value achieved by current instruments of 80% and increasing it to 100% would result in an improvement in contrast of a factor of $\sim$ 4 at 3$λ/D$ and $\sim$ 8 at 6$λ/D$. Achieving better contrast performance in this low flux regime would then require exploiting the information encoded in the photon arrival time statistics.
△ Less
Submitted 30 July, 2020;
originally announced July 2020.
-
A Frequency Selective Surface based focal plane receiver for the OLIMPO balloon-borne telescope
Authors:
Sumedh Mahashabde,
Alexander Sobolev,
Andreas Bengtsson,
Daniel Andrén,
Michael Tarasov,
Maria Salatino,
Paolo de Bernardis,
Silvia Masi,
Leonid Kuzmin
Abstract:
We describe here a focal plane array of Cold-Electron Bolometer (CEB) detectors integrated in a Frequency Selective Surface (FSS) for the 350 GHz detection band of the OLIMPO balloon-borne telescope. In our architecture, the two terminal CEB has been integrated in the periodic unit cell of the FSS structure and is impedance matched to the embedding impedance seen by it and provides a resonant inte…
▽ More
We describe here a focal plane array of Cold-Electron Bolometer (CEB) detectors integrated in a Frequency Selective Surface (FSS) for the 350 GHz detection band of the OLIMPO balloon-borne telescope. In our architecture, the two terminal CEB has been integrated in the periodic unit cell of the FSS structure and is impedance matched to the embedding impedance seen by it and provides a resonant interaction with the incident sub-mm radiation. The detector array has been designed to operate in background noise limited condition for incident powers of 20 pW to 80 pW, making it possible to use the same pixel in both photometric and spectrometric configurations. We present high frequency and dc simulations of our system, together with fabrication details. The frequency response of the FSS array, optical response measurements with hot/cold load in front of optical window and with variable temperature black body source inside cryostat are presented. A comparison of the optical response to the CEB model and estimations of Noise Equivalent power (NEP) is also presented.
△ Less
Submitted 11 May, 2015;
originally announced May 2015.
-
Cold-electron bolometers for future mm and sub-mm sky surveys
Authors:
Maria Salatino,
Paolo de Bernardis,
Sumedh Mahashabde,
Leonid S. Kuzmin,
Silvia Masi
Abstract:
Future sky surveys in the mm/sub-mm range, like the forthcoming balloon-borne missions LSPE, OLIMPO, SPIDER etc., will need detectors insensitive to cosmic rays (CRs) and with a NEP of the order of $10^{-17} ÷10^{-18}\,$W/sqrt(Hz). The Cold-Electron Bolometers (CEBs) technology is promising, having the required properties, since the absorber volume is extremely small and the electron system of the…
▽ More
Future sky surveys in the mm/sub-mm range, like the forthcoming balloon-borne missions LSPE, OLIMPO, SPIDER etc., will need detectors insensitive to cosmic rays (CRs) and with a NEP of the order of $10^{-17} ÷10^{-18}\,$W/sqrt(Hz). The Cold-Electron Bolometers (CEBs) technology is promising, having the required properties, since the absorber volume is extremely small and the electron system of the absorber is thermally insulated from the phonon system. We have developed an experimental setup to test the optical performance and the CRs insensitivity of CEBs, with the target of integrating them in the OLIMPO and LSPE focal planes.
△ Less
Submitted 21 October, 2014;
originally announced October 2014.
-
Sensitivity to Cosmic Rays of Cold Electron Bolometers for Space Applications
Authors:
Maria Salatino,
Paolo de Bernardis,
Leonid Kuzmin,
Sumedh Mahashabde,
Silvia Masi
Abstract:
An important phenomenon limiting the sensitivity of bolometric detectors for future space missions is the interaction with cosmic rays. We tested the sensitivity of Cold Electron Bolometers (CEBs) to ionizing radiation using gamma-rays from a radioactive source and X-rays from a X-ray tube. We describe the test setup and the results. As expected, due to the effective thermal insulation of the sens…
▽ More
An important phenomenon limiting the sensitivity of bolometric detectors for future space missions is the interaction with cosmic rays. We tested the sensitivity of Cold Electron Bolometers (CEBs) to ionizing radiation using gamma-rays from a radioactive source and X-rays from a X-ray tube. We describe the test setup and the results. As expected, due to the effective thermal insulation of the sensing element and its negligible volume, we find that CEBs are largely immune to this problem.
△ Less
Submitted 30 March, 2014;
originally announced March 2014.