-
CCAT: LED Mapping and Characterization of the 280 GHz TiN KID Array
Authors:
Alicia Middleton,
Steve K. Choi,
Samantha Walker,
Jason Austermann,
James R. Burgoyne,
Victoria Butler,
Scott C. Chapman,
Abigail T. Crites,
Cody J. Duell,
Rodrigo G. Freundt,
Anthony I. Huber,
Zachary B. Huber,
Johannes Hubmayr,
Ben Keller,
Lawrence T. Lin,
Michael D. Niemack,
Darshan Patel,
Adrian K. Sinclair,
Ema Smith,
Anna Vaskuri,
Eve M. Vavagiakis,
Michael Vissers,
Yuhan Wang,
Jordan Wheeler
Abstract:
Prime-Cam, one of the primary instruments for the Fred Young Submillimeter Telescope (FYST) developed by the CCAT Collaboration, will house up to seven instrument modules, with the first operating at 280 GHz. Each module will include three arrays of superconducting microwave kinetic inductance detectors (KIDs). The first KID array fabricated for the 280 GHz module uses titanium-nitride (TiN) as th…
▽ More
Prime-Cam, one of the primary instruments for the Fred Young Submillimeter Telescope (FYST) developed by the CCAT Collaboration, will house up to seven instrument modules, with the first operating at 280 GHz. Each module will include three arrays of superconducting microwave kinetic inductance detectors (KIDs). The first KID array fabricated for the 280 GHz module uses titanium-nitride (TiN) as the superconducting material and has 3,456 individual detectors, while the other two arrays use aluminum. This paper presents the design and laboratory characterization of the 280 GHz TiN array, which is cooled below its critical temperature to ~0.1 K and read out over six RF feedlines. LED mapping, a technique for matching the measured resonant frequency of a detector to its physical position, was performed on the array so that the results can be used to lithographically trim the KID capacitors and increase the yield of the array by reducing frequency collisions. We present the methods and results of LED mapping the 280 GHz TiN KID array before deployment on FYST.
△ Less
Submitted 28 October, 2024;
originally announced October 2024.
-
CCAT: Nonlinear effects in 280 GHz aluminum kinetic inductance detectors
Authors:
Cody J. Duell,
Jason Austermann,
James R. Burgoyne,
Scott C. Chapman,
Steve K. Choi,
Abigail T. Crites,
Rodrigo G. Freundt,
Anthony I. Huber,
Zachary B. Huber,
Johannes Hubmayr,
Ben Keller,
Lawrence T. Lin,
Alicia M. Middleton,
Colin C. Murphy,
Michael D. Niemack,
Thomas Nikola,
Darshan Patel,
Adrian K. Sinclair,
Ema Smith,
Gordon J. Stacey,
Anna Vaskuri,
Eve M. Vavagiakis,
Michael Vissers,
Samantha Walker,
Jordan Wheeler
Abstract:
Prime-Cam, a first-generation science instrument for the Atacama-based Fred Young Submillimeter Telescope, is being built by the CCAT Collaboration to observe at millimeter and submillimeter wavelengths using kinetic inductance detectors (KIDs). Prime-Cam's 280 GHz instrument module will deploy with two aluminum-based KID arrays and one titanium nitride-based KID array, totaling approximately 10,0…
▽ More
Prime-Cam, a first-generation science instrument for the Atacama-based Fred Young Submillimeter Telescope, is being built by the CCAT Collaboration to observe at millimeter and submillimeter wavelengths using kinetic inductance detectors (KIDs). Prime-Cam's 280 GHz instrument module will deploy with two aluminum-based KID arrays and one titanium nitride-based KID array, totaling approximately 10,000 detectors at the focal plane, all of which have been fabricated and are currently undergoing testing. One complication of fielding large arrays of KIDs under dynamic loading conditions is tuning the detector tone powers to maximize signal-to-noise while avoiding bifurcation due to the nonlinear kinetic inductance. For aluminum-based KIDs, this is further complicated by additional nonlinear effects which couple tone power to resonator quality factors and resonant frequencies. While both nonequilibrium quasiparticle dynamics and two-level system fluctuations have been shown to give rise to qualitatively similar distortions, modeling these effects alongside nonlinear kinetic inductance is inefficient when fitting thousands of resonators on-sky with existing models. For this reason, it is necessary to have a detailed understanding of the nonlinear effects across relevant detector loading conditions, including how they impact on on-sky noise and how to diagnose the detector's relative performance. We present a study of the competing nonlinearities seen in Prime-Cam's 280 GHz aluminum KIDs, with a particular emphasis on the resulting distortions to the resonator line shape and how these impact detector parameter estimation.
△ Less
Submitted 3 September, 2024;
originally announced September 2024.
-
CCAT: Prime-Cam Optics Overview and Status Update
Authors:
Zachary B. Huber,
Lawrence T. Lin,
Eve M. Vavagiakis,
Rodrigo G. Freundt,
Victoria Butler,
Scott C. Chapman,
Steve K. Choi,
Abigail T. Crites,
Cody J. Duell,
Patricio A. Gallardo,
Anthony I. Huber,
Ben Keller,
Alicia Middleton,
Michael D. Niemack,
Thomas Nikola,
John Orlowski-Scherer,
Ema Smith,
Gordon Stacey,
Samantha Walker,
Bugao Zou
Abstract:
Prime-Cam is a first-generation science instrument for the CCAT Observatory's six-meter aperture Fred Young Submillimeter Telescope (FYST). FYST's crossed-Dragone design provides high optical throughput to take advantage of its unique site at 5600 m on Cerro Chajnantor in Chile's Atacama Desert to reach mapping speeds over ten times greater than current and near-term submillimeter experiments. Hou…
▽ More
Prime-Cam is a first-generation science instrument for the CCAT Observatory's six-meter aperture Fred Young Submillimeter Telescope (FYST). FYST's crossed-Dragone design provides high optical throughput to take advantage of its unique site at 5600 m on Cerro Chajnantor in Chile's Atacama Desert to reach mapping speeds over ten times greater than current and near-term submillimeter experiments. Housing up to seven independent instrument modules in its 1.8-meter diameter cryostat, Prime-Cam will combine broadband polarization-sensitive modules and spectrometer modules designed for observations in several frequency windows between 210 GHz and 850 GHz to study a wide range of astrophysical questions from Big Bang cosmology to the formation of stars and galaxies in the Epoch of Reionization and beyond. In order to cover this range of frequencies and observation modes, each of the modules contains a set of cold reimaging optics that is optimized for the science goals of that module. These optical setups include several filters, three or four anti-reflection-coated silicon lenses, and a Lyot stop to control the field of view and illumination of the primary mirror, satisfy a series of mechanical constraints, and maximize optical performance within each passband. We summarize the design considerations and trade-offs for the optics in these modules and provide a status update on the fabrication of the Prime-Cam receiver and the design of its 1 K and 100 mK thermal BUSs.
△ Less
Submitted 30 July, 2024;
originally announced July 2024.
-
Thermal and mechanical study of a parametrised cryostat model for optical characterisation of upcoming CMB experiments
Authors:
Thomas J. L. J. Gascard,
Yi Wang,
Jon E. Gudmundsson,
Eve M. Vavagiakis,
Cody J. Duell,
Zachary B. Huber,
Lawrence T. Lin,
Michael D. Niemack,
Rodrigo G. Freundt
Abstract:
Current and future experiments observing the cosmic microwave background require a detailed understanding of optical performance at cryogenic temperatures. Pre-deployment analysis of optics can be performed in custom-engineered cryogenic test beds, such as Mod-Cam, a first light camera for the CCAT project. This work presents studies of the mechanical and thermal performance of CryoSim, a model of…
▽ More
Current and future experiments observing the cosmic microwave background require a detailed understanding of optical performance at cryogenic temperatures. Pre-deployment analysis of optics can be performed in custom-engineered cryogenic test beds, such as Mod-Cam, a first light camera for the CCAT project. This work presents studies of the mechanical and thermal performance of CryoSim, a model of a generic cylindrical 4-K cryostat cooled with a commercial pulse tube cryocooler that can be used to characterise optical components and full reimaging optical systems. CryoSim is extensively parametrised, allowing the joint analysis and optimisation of mechanical and thermal performance via finite element methods. Results from this model are validated against measured cooldown data of the Mod-Cam cryostat. Due to the extensive parametrisation of the model, significant modifications of the cryostat geometry may be implemented to be representative of any system the scientific community may desire, and validation of thermal and mechanical performance can be carried out rapidly.
△ Less
Submitted 5 July, 2024;
originally announced July 2024.
-
CCAT: Comparisons of 280 GHz TiN and Al Kinetic Inductance Detector Arrays
Authors:
Cody J. Duell,
Jason Austermann,
James Beall,
James R. Burgoyne,
Scott C. Chapman,
Steve K. Choi,
Rodrigo G. Freundt,
Jiansong Gao,
Christopher Groppi,
Anthony I. Huber,
Zachary B. Huber,
Johannes Hubmayr,
Ben Keller,
Yaqiong Li,
Lawrence T. Lin,
Justin Matthewson,
Philip Mauskopf,
Alicia Middleton,
Colin C. Murphy,
Michael D. Niemack,
Thomas Nikola,
Adrian K. Sinclair,
Ema Smith,
Jeff van Lanen,
Anna Vaskuri
, et al. (5 additional authors not shown)
Abstract:
The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submilli…
▽ More
The CCAT Collaboration's six-meter Fred Young Submillimeter Telescope is scheduled to begin observing in the Chilean Atacama in 2025, targeting a variety of science goals throughout cosmic history. Prime-Cam is a 1.8-meter diameter cryostat that will host up to seven independent instrument modules designed for simultaneous spectroscopic and broadband, polarimetric surveys at millimeter to submillimeter wavelengths. The first of these instrument modules, the 280 GHz module, will include ${\sim}$10,000 kinetic inductance detectors (KIDs) across three arrays. While the first array was fabricated out of tri-layer TiN/Ti/TiN, the other two arrays were fabricated out of a single layer of Al. This combination of materials within the same instrument provides a unique opportunity to directly compare the performance and noise properties of two different detector materials that are seeing increasing use within the field. We present preliminary comparisons here based on lab testing, along with a discussion of the potential impacts on operation when observing and translating raw data to science-grade maps.
△ Less
Submitted 10 June, 2024;
originally announced June 2024.
-
The Simons Observatory: Design, integration, and testing of the small aperture telescopes
Authors:
Nicholas Galitzki,
Tran Tsan,
Jake Spisak,
Michael Randall,
Max Silva-Feaver,
Joseph Seibert,
Jacob Lashner,
Shunsuke Adachi,
Sean M. Adkins,
Thomas Alford,
Kam Arnold,
Peter C. Ashton,
Jason E. Austermann,
Carlo Baccigalupi,
Andrew Bazarko,
James A. Beall,
Sanah Bhimani,
Bryce Bixler,
Gabriele Coppi,
Lance Corbett,
Kevin D. Crowley,
Kevin T. Crowley,
Samuel Day-Weiss,
Simon Dicker,
Peter N. Dow
, et al. (55 additional authors not shown)
Abstract:
The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of $σ(r)=0.002$, with quantified systematic errors well below this value. Each SAT…
▽ More
The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of $σ(r)=0.002$, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35$^\circ$ field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and $<0.1$ K focal plane that holds $>12,000$ TES detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.
△ Less
Submitted 10 May, 2024; v1 submitted 9 May, 2024;
originally announced May 2024.
-
The Simons Observatory: Large-Scale Characterization of 90/150 GHz TES Detector Modules
Authors:
Daniel Dutcher,
Shannon M. Duff,
John C. Groh,
Erin Healy,
Johannes Hubmayr,
Bradley R. Johnson,
Dante Jones,
Ben Keller,
Lawrence T. Lin,
Michael J. Link,
Tammy J. Lucas,
Samuel Morgan,
Yudai Seino,
Rita F. Sonka,
Suzanne T. Staggs,
Yuhan Wang,
Kaiwen Zheng
Abstract:
The Simons Observatory (SO) is a cosmic microwave background instrumentation suite being deployed in the Atacama Desert in northern Chile. The telescopes within SO use three types of dichroic transition-edge sensor (TES) detector arrays, with the 90 and 150 GHz Mid-Frequency (MF) arrays containing 65% of the approximately 68,000 detectors in the first phase of SO. All of the 26 required MF detecto…
▽ More
The Simons Observatory (SO) is a cosmic microwave background instrumentation suite being deployed in the Atacama Desert in northern Chile. The telescopes within SO use three types of dichroic transition-edge sensor (TES) detector arrays, with the 90 and 150 GHz Mid-Frequency (MF) arrays containing 65% of the approximately 68,000 detectors in the first phase of SO. All of the 26 required MF detector arrays have now been fabricated, packaged into detector modules, and tested in laboratory cryostats. Across all modules, we find an average operable detector yield of 84% and median saturation powers of (2.8, 8.0) pW with interquartile ranges of (1, 2) pW at (90, 150) GHz, respectively, falling within their targeted ranges. We measure TES normal resistances and superconducting transition temperatures on each detector wafer to be uniform within 3%, with overall central values of 7.5 mohm and 165 mK, respectively. Results on time constants, optical efficiency, and noise performance are also presented and are consistent with achieving instrument sensitivity forecasts.
△ Less
Submitted 29 January, 2024; v1 submitted 9 November, 2023;
originally announced November 2023.
-
CCAT-prime: Optical and cryogenic design of the 850 GHz module for Prime-Cam
Authors:
Anthony I. Huber,
Scott C. Chapman,
Adrian K. Sinclair,
Locke D. Spencer,
Jason E. Austermann,
Steve K. Choi,
Jesslyn Devina,
Patricio A. Gallardo,
Doug Henke,
Zachary B. Huber,
Ben Keller,
Yaqiong Li,
Lawrence T. Lin,
Mike Niemack,
Kayla M. Rossi,
Eve M. Vavagiakis,
Jordan D. Wheeler
Abstract:
Prime-Cam is a first-generation instrument for the Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) Facility. The 850$~$GHz module for Prime-Cam will probe the highest frequency of all the instrument modules. We describe the parameter space of the 850$~$GHz optical system between the F$λ$ spacing, beam size, pixel sensitivity, and detector count. We present the optimization of an optical desi…
▽ More
Prime-Cam is a first-generation instrument for the Cerro Chajnantor Atacama Telescope-prime (CCAT-prime) Facility. The 850$~$GHz module for Prime-Cam will probe the highest frequency of all the instrument modules. We describe the parameter space of the 850$~$GHz optical system between the F$λ$ spacing, beam size, pixel sensitivity, and detector count. We present the optimization of an optical design for the 850$~$GHz instrument module for CCAT-prime. We further describe the development of the cryogenic RF chain design to accommodate $>$30 readout lines to read 41,400 kinetic inductance detectors (KIDs) within the cryogenic testbed.
△ Less
Submitted 19 August, 2022;
originally announced August 2022.
-
CCAT-prime: The Optical Design for the Epoch of Reionization Spectrometer
Authors:
Zachary B. Huber,
Steve K. Choi,
Cody J. Duell,
Rodrigo G. Freundt,
Patricio A. Gallardo,
Ben Keller,
Yaqiong Li,
Lawrence T. Lin,
Michael D. Niemack,
Thomas Nikola,
Dominik A. Riechers,
Gordon Stacey,
Eve M. Vavagiakis,
Bugao Zou
Abstract:
The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its Fabry-Perot interferometer (FPI), EoR-Spec will step through frequencies between 210 and 420 GHz to perform line intensity mapping of the 158 $μ$m [CII] line in…
▽ More
The Epoch of Reionization Spectrometer (EoR-Spec) will be an instrument module for the Prime-Cam receiver on the CCAT-prime Collaboration's Fred Young Submillimeter Telescope (FYST), a 6-m primary mirror Crossed Dragone telescope. With its Fabry-Perot interferometer (FPI), EoR-Spec will step through frequencies between 210 and 420 GHz to perform line intensity mapping of the 158 $μ$m [CII] line in aggregates of star-forming galaxies between redshifts of 3.5 and 8 to trace the evolution of structure in the universe during the epoch of reionization. Here we present the optical design of the module including studies of the optical quality and other key parameters at the image surface. In order to achieve the required resolving power (R$\sim$100) with the FPI, it is important to have a highly collimated beam at the Lyot stop of the system; the optimization process to achieve this goal with four lenses instead of three as used in other Prime-Cam modules is outlined. As part of the optimization, we test the effect of replacing some of the aspheric lenses with biconic lenses in this Crossed Dragone design and find that the biconic lenses tend to improve the image quality across the focal plane of the module.
△ Less
Submitted 19 August, 2022;
originally announced August 2022.