-
PSFs for mapping artificial night sky luminance over large territories
Authors:
Alexandre Simoneau,
Martin Aubé,
Jérôme Leblanc,
Rémi Boucher,
Johanne Roby,
Florence Lacharité
Abstract:
Knowledge of the night sky radiance over a large territory may be valuable informationto identify sites appropriate to astronomical observations or for assessing the impacts ofartificial light at night on ecosystems. Measuring the sky radiance can be a complex endeavourdepending on the desired temporal and spatial resolution. Similarly, modelling of artificialnight sky radiance for multiple points…
▽ More
Knowledge of the night sky radiance over a large territory may be valuable informationto identify sites appropriate to astronomical observations or for assessing the impacts ofartificial light at night on ecosystems. Measuring the sky radiance can be a complex endeavourdepending on the desired temporal and spatial resolution. Similarly, modelling of artificialnight sky radiance for multiple points of a territory can represent a significant amount ofcomputing time depending on the complexity of the model used. The use of the convolutionof a point spread function with the light sources geographical distribution has been suggestedin order to model the sky radiance over large territories of hundreds of kilometres in size.We determine how the point spread function is sensitive to the main driving parameters ofthe artificial night sky radiance such as the wavelength, the ground reflectance, the obstaclesproperties, the Upward Light Output Ratio and the Aerosol Optical Depth using the Illuminav2 model. The obtained functions were used to model the artificial night sky brightness ofthe Mont-Mégantic International Dark Sky Reserve for winter and summer conditions. Theresults were compared to the New world atlas of artificial night sky brightness, the Illuminav2 model and in situ Sky Quality Camera measurements. We found that the New world atlasoverestimates the artificial sky brightness by 55% whereas the Illumina model underestimatesit by 48%. This may be due to varying atmospherical conditions and the fact that the modelonly accounts for public light sources.
△ Less
Submitted 4 March, 2021;
originally announced March 2021.
-
The ROSEBUD experiment at Canfranc: 2001 report
Authors:
S. Cebrian,
N. Coron,
G. Dambier,
E. Garcia,
I. G. Irastorza,
J. Leblanc,
P. de Marcillac,
A. Morales,
J. Morales,
A. Ortiz de Solorzano,
J. Puimedon,
M. L. Sarsa,
J. A. Villar
Abstract:
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in the Canfranc Underground Laboratory. The first phase of the experiment was dedicated to the understanding and reduction of the radioactive background following successive removals of the radioimpure materials. Sapphire (25g, 50g) and germanium (67g) absorbers were used. Thresholds respectively lower than 1keV and 450 eV w…
▽ More
The ROSEBUD experiment for Direct Dark Matter detection settled in 1999 in the Canfranc Underground Laboratory. The first phase of the experiment was dedicated to the understanding and reduction of the radioactive background following successive removals of the radioimpure materials. Sapphire (25g, 50g) and germanium (67g) absorbers were used. Thresholds respectively lower than 1keV and 450 eV were achieved on these detectors. The second phase of the experiment plans to use scintillating bolometers to discriminate between recoiling nuclei and electrons. Prototypes using commercial CaWO4 (54g) and BGO (46g) were designed for this purpose. While internal contamination was found and identified in both targets, neutron calibrations revealed their high discrimination power. A 6 keV threshold on the heat channel of the BGO bolometer points out the interest of such a novel material, for Dark Matter research on neutralinos having spin-dependent or spin-independent interactions.
△ Less
Submitted 3 January, 2002; v1 submitted 12 December, 2001;
originally announced December 2001.
-
First results of the ROSEBUD Dark Matter experiment
Authors:
S. Cebrian,
N. Coron,
G. Dambier,
E. Garcia,
D. Gonzalez,
I. G. Irastorza,
J. Leblanc,
P. de Marcillac,
A. Morales,
J. Morales,
A. Ortiz de Solorzano,
A. Peruzzi,
J. Puimedon,
M. L. Sarsa,
S. Scopel,
J. A. Villar
Abstract:
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through their elastic scattering off Al and O nuclei. It consists of three small sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a dilution refrigerator operating at 20 mK in the Canfranc Underground Laboratory. We report in this pap…
▽ More
Rare Objects SEarch with Bolometers UndergrounD) is an experiment which attempts to detect low mass Weak Interacting Massive Particles (WIMPs) through their elastic scattering off Al and O nuclei. It consists of three small sapphire bolometers (of a total mass of 100 g) with NTD-Ge sensors in a dilution refrigerator operating at 20 mK in the Canfranc Underground Laboratory. We report in this paper the results of several runs (of about 10 days each) with successively improved energy thresholds, and the progressive background reduction obtained by improvement of the radiopurity of the components and subsequent modifications in the experimental assembly, including the addition of old lead shields. Mid-term plans and perspectives of the experiment are also presented.
△ Less
Submitted 20 April, 2000;
originally announced April 2000.
-
Calibration and First light of the Diabolo photometer at the Millimetre and Infrared Testa Grigia Observatory
Authors:
A. Benoit,
F. Zagury,
N. Coron,
M. De Petris,
F. -X. Desert,
M. Giard,
J. -P. Bernard,
J. -P. Crussaire,
G. Dambier,
P. de Bernardis,
J. Delabrouille,
A. De Luca,
P. de Marcillac,
G. Jegoudez,
J. -M. Lamarre,
J. Leblanc,
J. -P. Lepeltier,
B. Leriche,
G. Mainella,
J. Narbonne,
F. Pajot,
R. Pons,
J. -L. Puget,
S. Pujol,
G. Recouvreur
, et al. (4 additional authors not shown)
Abstract:
We have designed and built a large-throughput dual channel photometer,
Diabolo. This photometer is dedicated to the observation of millimetre continuum diffuse sources, and in particular, of the Sunyaev-Zel'dovich effect and of anisotropies of the 3K background. We describe the optical layout and filtering system of the instrument, which uses two bolometric detectors for simultaneous observati…
▽ More
We have designed and built a large-throughput dual channel photometer,
Diabolo. This photometer is dedicated to the observation of millimetre continuum diffuse sources, and in particular, of the Sunyaev-Zel'dovich effect and of anisotropies of the 3K background. We describe the optical layout and filtering system of the instrument, which uses two bolometric detectors for simultaneous observations in two frequency channels at 1.2 and 2.1 mm. The bolometers are cooled to a working temperature of 0.1 K provided by a compact dilution cryostat. The photometric and angular responses of the instrument are measured in the laboratory. First astronomical light was detected in March 1995 at the focus of the new Millimetre and Infrared Testa Grigia Observatory (MITO) Telescope. The established sensitivity of the system is of 7 mK_RJ s^1/2$. For a typical map of at least 10 beams, with one hour of integration per beam, one can achieve the rms values of y_SZ ~ 7 10^-5 and the 3K background anisotropy Delta T/T ~ 7 10^-5, in winter conditions. We also report on a novel bolometer AC readout circuit which allows for the first time total power measurements on the sky. This technique alleviates (but does not forbid) the use of chopping with a secondary mirror. This technique and the dilution fridge concept will be used in future scan--modulated space instrument like the ESA Planck mission project.
△ Less
Submitted 17 December, 1999;
originally announced December 1999.