-
A multi-channel silicon package for large-scale skipper-CCD experiments
Authors:
A. M. Botti,
C. Chavez,
M. Sofo-Haro,
C. S. Miller,
F. Chierchie,
M. Jonas,
M. Lisovenko,
H. Gutti,
D. Czaplewski,
A. Lathrop,
J. Tiffenberg,
G. Fernandez-Moroni,
J. Estrada
Abstract:
The next generation of experiments for rare-event searches based on skipper Charge Coupled Devices (skipper-CCDs) presents new challenges for the sensor packaging and readout. Scaling the active mass and simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present…
▽ More
The next generation of experiments for rare-event searches based on skipper Charge Coupled Devices (skipper-CCDs) presents new challenges for the sensor packaging and readout. Scaling the active mass and simultaneously reducing the experimental backgrounds in orders of magnitude requires a novel high-density silicon-based package that must be massively produced and tested. In this work, we present the design, fabrication, testing, and empirical signal model of a multi-channel silicon package. In addition, we outline the chosen specifications for the ongoing production of 1500 wafers that will add up to a 10 kg skipper-CCD array with 24000 readout channels.
△ Less
Submitted 12 January, 2025; v1 submitted 8 October, 2024;
originally announced October 2024.
-
The Oscura Experiment
Authors:
Alexis Aguilar-Arevalo,
Fabricio Alcalde Bessia,
Nicolas Avalos,
Daniel Baxter,
Xavier Bertou,
Carla Bonifazi,
Ana Botti,
Mariano Cababie,
Gustavo Cancelo,
Brenda Aurea Cervantes-Vergara,
Nuria Castello-Mor,
Alvaro Chavarria,
Claudio R. Chavez,
Fernando Chierchie,
Juan Manuel De Egea,
Juan Carlos D`Olivo,
Cyrus E. Dreyer,
Alex Drlica-Wagner,
Rouven Essig,
Juan Estrada,
Ezequiel Estrada,
Erez Etzion,
Guillermo Fernandez-Moroni,
Marivi Fernandez-Serra,
Steve Holland
, et al. (19 additional authors not shown)
Abstract:
The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensi…
▽ More
The Oscura experiment will lead the search for low-mass dark matter particles using a very large array of novel silicon Charge Coupled Devices (CCDs) with a threshold of two electrons and with a total exposure of 30 kg-yr. The R&D effort, which began in FY20, is currently entering the design phase with the goal of being ready to start construction in late 2024. Oscura will have unprecedented sensitivity to sub-GeV dark matter particles that interact with electrons, probing dark matter-electron scattering for masses down to 500 keV and dark matter being absorbed by electrons for masses down to 1 eV. The Oscura R&D effort has made some significant progress on the main technical challenges of the experiment, of which the most significant are engaging new foundries for the fabrication of the CCD sensors, developing a cold readout solution, and understanding the experimental backgrounds.
△ Less
Submitted 23 February, 2022; v1 submitted 21 February, 2022;
originally announced February 2022.
-
Interplay between phonon downconversion efficiency, density of states at Fermi energy, and intrinsic energy resolution for microwave kinectic inductance detectors
Authors:
Israel Hernandez,
Gustavo Cancelo,
Juan Estrada,
Humberto Gonzalez,
Andrew Lathrop,
Martin Makler,
Chris Stoughto
Abstract:
Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here,…
▽ More
Microwave Kinetic Inductance detectors (MKIDs) have been recognized as a powerful new tool for single photon detection. These highly multiplexed superconducting devices give timing and energy measurement for every detected photon. However, the full potential of MKID single photon spectroscopy has not been reached , the achieved energy resolution is lower than expected from first principles. Here, we study the efficiency in the phonon downconversion process following the absorption of energetic photons in MKIDs. Assuming previously published material properties, we measure an average downconversion efficiency for three TiN resonators is $η$=0.14. We discuss how this efficiency can impact the intrinsic energy resolution of MKID, and how any uncertainty in the unknown density of electron states at the Fermi energy directly affects the efficiency estimations.
△ Less
Submitted 6 April, 2020;
originally announced April 2020.
-
A measurement of the ionization efficiency of nuclear recoils in silicon
Authors:
F. Izraelevitch,
D. Amidei,
A. Aprahamian,
R. Arcos-Olalla,
G. Cancelo,
C. Casarella,
A. E. Chavarria,
P. Collon,
J. Estrada,
G. Fernández Moroni,
Y. Guardincerri,
G. Gutiérrez,
A. Gyurjinyan,
A. Kavner,
B. Kilminster,
A. Lathrop,
J. Liao,
Q. Liu,
M. López,
J. Molina,
P. Privitera,
M. A. Reyes,
V. Scarpine,
K. Siegl,
M. Smith
, et al. (4 additional authors not shown)
Abstract:
We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron spectrum was used and the nuclear recoil energy was reconstructed using a measurement of the time of flight and scattering angle of the scattered neutron. The over…
▽ More
We have measured the ionization efficiency of silicon nuclear recoils with kinetic energy between 1.8 and 20 keV. We bombarded a silicon-drift diode with a neutron beam to perform an elastic-scattering experiment. A broad-energy neutron spectrum was used and the nuclear recoil energy was reconstructed using a measurement of the time of flight and scattering angle of the scattered neutron. The overall trend of the results of this work is well described by the theory of Lindhard et al. above 4 keV of recoil energy. Below this energy, the presented data shows a deviation from the model. The data indicates a faster drop than the theory prediction at low energies.
△ Less
Submitted 4 July, 2017; v1 submitted 2 February, 2017;
originally announced February 2017.
-
The Dark Energy Camera
Authors:
B. Flaugher,
H. T. Diehl,
K. Honscheid,
T. M. C. Abbott,
O. Alvarez,
R. Angstadt,
J. T. Annis,
M. Antonik,
O. Ballester,
L. Beaufore,
G. M. Bernstein,
R. A. Bernstein,
B. Bigelow,
M. Bonati,
D. Boprie,
D. Brooks,
E. J. Buckley-Geer,
J. Campa,
L. Cardiel-Sas,
F. J. Castander,
J. Castilla,
H. Cease,
J. M. Cela-Ruiz,
S. Chappa,
E. Chi
, et al. (93 additional authors not shown)
Abstract:
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses…
▽ More
The Dark Energy Camera is a new imager with a 2.2-degree diameter field of view mounted at the prime focus of the Victor M. Blanco 4-meter telescope on Cerro Tololo near La Serena, Chile. The camera was designed and constructed by the Dark Energy Survey Collaboration, and meets or exceeds the stringent requirements designed for the wide-field and supernova surveys for which the collaboration uses it. The camera consists of a five element optical corrector, seven filters, a shutter with a 60 cm aperture, and a CCD focal plane of 250 micron thick fully-depleted CCDs cooled inside a vacuum Dewar. The 570 Mpixel focal plane comprises 62 2kx4k CCDs for imaging and 12 2kx2k CCDs for guiding and focus. The CCDs have 15 microns x15 microns pixels with a plate scale of 0.263 arc sec per pixel. A hexapod system provides state-of-the-art focus and alignment capability. The camera is read out in 20 seconds with 6-9 electrons readout noise. This paper provides a technical description of the camera's engineering, construction, installation, and current status.
△ Less
Submitted 11 April, 2015;
originally announced April 2015.