-
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Abstract: The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used t… ▽ More
Submitted 19 December, 2011; v1 submitted 11 January, 2011; originally announced January 2011.
Comments: Published version
Journal ref: A&A Vol 536, A3 (Dec 2011)
-
Design, development, and verification of the Planck Low Frequency Instrument 70 GHz Front-End and Back-End Modules
Abstract: 70 GHz radiometer front-end and back-end modules for the Low Frequency Instrument of the European Space Agencys Planck Mission were built and tested. The operating principles and the design details of the mechanical structures are described along with the key InP MMIC low noise amplifiers and phase switches of the units. The units were tested in specially designed cryogenic vacuum chambers capab… ▽ More
Submitted 26 January, 2010; originally announced January 2010.
Comments: 16 pages, 15 figures. This paper is part of of the prelaunch status Planck LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst
-
arXiv:1001.4644 [pdf, ps, other]
Cryogenic environment and performance for testing the Planck radiometers
Abstract: This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced… ▽ More
Submitted 26 January, 2010; originally announced January 2010.
Comments: This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12015
Journal ref: Journal of Instrumentation, Volume 4, 12, pp. T12015 (2009)
-
arXiv:1001.4610 [pdf, ps, other]
The linearity response of the Planck-LFI flight model receivers
Abstract: In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best para… ▽ More
Submitted 26 January, 2010; originally announced January 2010.
Comments: this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst; This is an author-created, un-copyedited version of an article accepted for publication in JINST. IOP Publishing Ltd is not responsible for any errors or omissions in this version of the manuscript or any version derived from it. The definitive publisher authenticated version is available online at 10.1088/1748-0221/4/12/T12011.
Journal ref: 2009 JINST 4 T12011