-
Comparing Instrument Spectral Sensitivity of Dissimilar Electromagnetic Haloscopes to Axion Dark Matter and High Frequency Gravitational Waves
Authors:
Michael E. Tobar,
Catriona A. Thomson,
William M. Campbell,
Aaron Quiskamp,
Jeremy F. Bourhill,
Benjamin T. McAllister,
Eugene N. Ivanov,
Maxim Goryachev
Abstract:
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon thet…
▽ More
It is known that haloscopes that search for dark matter axions via the axion-photon anomaly are also sensitive to gravitational radiation through the inverse Gertsenshtein effect. Recently this way of searching for high frequency gravitational waves has gained momentum as it has been shown that the strain sensitivities of such detectors are of the same order of sensitivity to the axion-photon theta angle. Thus, after calculating the sensitivity of a haloscope to an axion signal, we also have calculated the order of magnitude sensitivity to a gravitational wave signal of the same spectral and temporal form. However, it is unlikely that a gravitational wave and an axion signal will be of the same form, since physically the way the signals are generated are completely different. For gravitational wave detection, the spectral strain sensitivity is in units strain per square root Hz, is the natural way to compare the sensitivity of gravitational wave detectors due to its independence on the gravitational wave signal. In this work, we introduce a systematic way to calculate the spectral sensitivity of an axion haloscope, so instrument comparison may be achieved independent of signal assumptions and only depends on the axion to signal transduction sensitivity and noise in the instrument. Thus, the calculation of the spectral sensitivity not only allows the comparison of dissimilar axion detectors independent of signal, but also allows us to compare the order of magnitude gravitational wave sensitivity in terms of spectral strain sensitivity, allowing comparisons to standard gravitational wave detectors based on optical interferometers and resonant-mass technology.
△ Less
Submitted 16 October, 2022; v1 submitted 7 September, 2022;
originally announced September 2022.
-
Direct Search for Dark Matter Axions Excluding ALP Cogenesis in the 63-67 micro-eV Range, with The ORGAN Experiment
Authors:
Aaron P. Quiskamp,
Ben T. McAllister,
Paul Altin,
Eugene N. Ivanov,
Maxim Goryachev,
Michael E. Tobar
Abstract:
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situat…
▽ More
The standard model axion seesaw Higgs portal inflation (SMASH) model is a well motivated, self-contained description of particle physics over a range of energy scales that predicts axion dark matter particles to exist within the mass range of $50-200\,μ$eV. To scan these masses an axion haloscope under a strong constant magnetic field must operate between 12 to 48 GHz. The ORGAN experiment (situated in Perth, Australia) is a microwave cavity axion haloscope that aims to search the majority of the mass range predicted by the SMASH model. Here we present results of Phase 1a, the first experiment to scan and search for axions in the microwave Ku Band. Our initial scan sets a new limit on the coupling of axions to two photons of $g_{aγγ}\geq 3\times 10^{-12}\, \textrm{GeV}^{-1}$ over the mass range $63.2$ to $67.1~μ$eV with $95\%$ confidence. This result is the most sensitive to date in this mass range, sufficient to exclude the well motivated ALP (Axion Like Particle) cogenesis model for dark matter, which adds ALPs to the standard model in the early universe to simultaneously explain the observed baryon and dark matter densities. To attain this level of sensitivity we utilised a TM$_{010}$ cylindrical cavity resonator, scanned between 15.28 to 16.23 GHz through the utilisation of a tuning rod. Measurements were performed over a duration of 3.5 weeks with a $74\%$ duty cycle, with the resonator coupled to a low noise HEMT amplifier and placed inside a superconducting solenoidal electromagnet of 11.5 Tesla in magnetic field strength.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Rare Events Detected with a Bulk Acoustic Wave High Frequency Gravitational Wave Antenna
Authors:
Maxim Goryachev,
William M. Campbell,
Ik Siong Heng,
Serge Galliou,
Eugene N. Ivanov,
Michael E. Tobar
Abstract:
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5…
▽ More
This work describes the operation of a High Frequency Gravitational Wave detector based on a cryogenic Bulk Acoustic Wave (BAW) cavity and reports observation of rare events during 153 days of operation over two seperate experimental runs (Run 1 and Run 2). In both Run 1 and Run 2 two modes were simultaneously monitored. Across both runs, the 3rd overtone of the fast shear mode (3B) operating at 5.506 MHz was monitored, while in Run 1 the second mode was chosen to be the 5th OT of the slow shear mode (5C) operating at 8.392 MHz. However, in Run 2 the second mode was selected to be closer in frequency to the first mode, and chosen to be the 3rd overtone of the slow shear mode (3C) operating at 4.993 MHz. Two strong events were observed as transients responding to energy deposition within acoustic modes of the cavity. The first event occurred during Run 1 on the 12/05/2019 (UTC), and was observed in the 5.506 MHz mode, while the second mode at 8.392 MHz observed no event. During Run 2, a second event occurred on the 27/11/2019(UTC) and was observed by both modes. Timing of the events were checked against available environmental observations as well as data from other detectors. Various possibilities explaining the origins of the events are discussed.
△ Less
Submitted 22 July, 2021; v1 submitted 11 February, 2021;
originally announced February 2021.
-
Ultra stable and very low noise signal source using a cryocooled sapphire oscillator for VLBI
Authors:
Nitin R. Nand,
John G. Hartnett,
Eugene N. Ivanov,
Giorgio Santarelli
Abstract:
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected…
▽ More
Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected from the synthesizer seeded with a signal near 11.2 GHz from an ultra-stable cryocooled sapphire oscillator.
The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10 MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130 dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and 100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and sigma_y = 2.2 x 10^-15, at 1 s integration time.
The Allan Deviation of the total fractional frequency noise on the 10 MHz and 100 MHz signals derived from the synthesizer with the cryocooled sapphire oscillator, may be estimated as sigma_y = 5.2 x 10^-15 τ^-1 + 3.6 x 10^-15 τ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 τ^-1/2 + 3 x 10^-16, respectively, for 1 s < τ< 10^4 s.
We also calculate the coherence function, (a figure of merit in VLBI) for observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the cryocooled sapphire oscillator and an hydrogen maser. The results show that the cryocooled sapphire oscillator offers a significant advantage at frequencies above 100 GHz.
△ Less
Submitted 20 April, 2011;
originally announced April 2011.
-
Improved test of Lorentz Invariance in Electrodynamics using Rotating Cryogenic Sapphire Oscillators
Authors:
Paul L. Stanwix,
Michael E. Tobar,
Peter Wolf,
Clayton R. Locke,
Eugene N. Ivanov
Abstract:
We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters from the photon sector of the standard…
▽ More
We present new results from our test of Lorentz invariance, which compares two orthogonal cryogenic sapphire microwave oscillators rotating in the lab. We have now acquired over 1 year of data, allowing us to avoid the short data set approximation (less than 1 year) that assumes no cancelation occurs between the $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters from the photon sector of the standard model extension. Thus, we are able to place independent limits on all eight $\tildeκ_{e-}$ and $\tildeκ_{o+}$ parameters. Our results represents up to a factor of 10 improvement over previous non rotating measurements (which independently constrained 7 parameters), and is a slight improvement (except for $\tildeκ_{e-}^{ZZ}$) over results from previous rotating experiments that assumed the short data set approximation. Also, an analysis in the Robertson-Mansouri-Sexl framework allows us to place a new limit on the isotropy parameter $P_{MM}=δ-β+{1/2}$ of $9.4(8.1)\times10^{-11}$, an improvement of a factor of 2.
△ Less
Submitted 3 October, 2006; v1 submitted 19 September, 2006;
originally announced September 2006.
-
Rotating Resonator-Oscillator Experiments to Test Lorentz Invariance in Electrodynamics
Authors:
Michael E. Tobar,
Paul L. Stanwix,
Mohamad Susli,
Peter Wolf,
Clayton R. Locke,
Eugene N. Ivanov
Abstract:
In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Fin…
▽ More
In this work we outline the two most commonly used test theories (RMS and SME) for testing Local Lorentz Invariance (LLI) of the photon. Then we develop the general framework of applying these test theories to resonator experiments with an emphasis on rotating experiments in the laboratory. We compare the inherent sensitivity factors of common experiments and propose some new configurations. Finally we apply the test theories to the rotating cryogenic experiment at the University of Western Australia, which recently set new limits in both the RMS and SME frameworks [hep-ph/0506074].
△ Less
Submitted 17 October, 2005; v1 submitted 21 June, 2005;
originally announced June 2005.
-
Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators
Authors:
Paul L. Stanwix,
Michael E. Tobar,
Peter Wolf,
Mohamad Susli,
Clayton R. Locke,
Eugene N. Ivanov,
John Winterflood,
Frank van Kann
Abstract:
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Man…
▽ More
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on the previously unmeasured $\tildeκ_{e-}^{ZZ}$ component of $2.1(5.7)\times10^{-14}$, and set more stringent bounds by up to a factor of 7 on seven other components. In the RMS a more stringent bound of $-0.9(2.0)\times 10^{-10}$ on the isotropy parameter, $P_{MM}=δ- β+ {1/2}$ is set, which is more than a factor of 7 improvement. More detailed description of the experiment and calculations can be found in: hep-ph/0506200
△ Less
Submitted 21 July, 2005; v1 submitted 7 June, 2005;
originally announced June 2005.
-
Initial operation of the International Gravitational Event Collaboration
Authors:
G. A. Prodi,
I. S. Heng,
Z. A. Allen,
P. Astone,
L. Baggio,
M. Bassan,
D. G. Blair,
M. Bonaldi,
P. Bonifazi,
P. Carelli,
M. Cerdonio,
E. Coccia,
L. Conti,
C. Cosmelli,
V. Crivelli Visconti,
S. D'Antonio,
V. Fafone,
P. Falferi,
P. Fortini,
S. Frasca,
W. O. Hamilton,
E. N. Ivanov,
W. W. Johnson,
C. R. Locke,
A. Marini
, et al. (24 additional authors not shown)
Abstract:
The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is…
▽ More
The International Gravitational Event Collaboration, IGEC, is a coordinated effort by research groups operating gravitational wave detectors working towards the detection of millisecond bursts of gravitational waves. Here we report on the current IGEC resonant bar observatory, its data analysis procedures, the main properties of the first exchanged data set. Even though the available data set is not complete, in the years 1997 and 1998 up to four detectors were operating simultaneously. Preliminary results are mentioned.
△ Less
Submitted 8 March, 2000;
originally announced March 2000.