Skip to main content

Showing 1–28 of 28 results for author: Iguaz, F J

Searching in archive astro-ph. Search in all archives.
.
  1. arXiv:2504.00079  [pdf, other

    hep-ph astro-ph.HE astro-ph.SR hep-ex

    The International Axion Observatory (IAXO): case, status and plans. Input to the European Strategy for Particle Physics

    Authors: A. Arcusa, S. Ahyoune, K. Altenmuller, I. Antolin, S. Basso, P. Brun, V. Burwitz, F. R. Candon, J. F. Castel, S. Cebrian, D. Chouhan, R. Della Ceca, M. Cervera-Cortes, M. M. Civitani, C. Cogollos, E. Costa, V. Cotroneo, T. Dafni, K. Desch, M. C. Diaz-Martin, A. Diaz-Morcillo, D. Diez-Ibanez, C. Diez Pardos, M. Dinter, B. Dobrich , et al. (98 additional authors not shown)

    Abstract: The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to search for solar axions with unprecedented sensitivity. IAXO holds a unique position in the global landscape of axion searches, as it will probe a region of the axion parameter space inaccessible to any other experiment. In particular, it will explore QCD axion models in the mass range from meV to eV, cove… ▽ More

    Submitted 31 March, 2025; originally announced April 2025.

    Comments: 10 pages, 2 figures. Input to the European Strategy for Particle Physics

  2. arXiv:2411.13915  [pdf, other

    hep-ex astro-ph.IM astro-ph.SR physics.comp-ph physics.data-an

    An accurate solar axions ray-tracing response of BabyIAXO

    Authors: S. Ahyoune, K. Altenmueller, I. Antolin, S. Basso, P. Brun, F. R. Candon, J. F. Castel, S. Cebrian, D. Chouhan, R. Della Ceca, M. Cervera-Cortes, V. Chernov, M. M. Civitani, C. Cogollos, E. Costa, V. Cotroneo, T. Dafni, A. Derbin, K. Desch, M. C. Diaz-Martin, A. Diaz-Morcillo, D. Diez-Ibanez, C. Diez Pardos, M. Dinter, B. Doebrich , et al. (102 additional authors not shown)

    Abstract: BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at th… ▽ More

    Submitted 29 November, 2024; v1 submitted 21 November, 2024; originally announced November 2024.

    Comments: 36 pages, 18 figures, 4 tables, Submitted to JHEP

  3. arXiv:2010.12076  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory

    Authors: A. Abeln, K. Altenmüller, S. Arguedas Cuendis, E. Armengaud, D. Attié, S. Aune, S. Basso, L. Bergé, B. Biasuzzi, P. T. C. Borges De Sousa, P. Brun, N. Bykovskiy, D. Calvet, J. M. Carmona, J. F. Castel, S. Cebrián, V. Chernov, F. E. Christensen, M. M. Civitani, C. Cogollos, T. Dafní, A. Derbin, K. Desch, D. Díez, M. Dinter , et al. (101 additional authors not shown)

    Abstract: This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for… ▽ More

    Submitted 4 March, 2021; v1 submitted 22 October, 2020; originally announced October 2020.

    Comments: 77 pages, 49 figures. Prepared for submission to JHEP. Third version after referees comments

  4. arXiv:1906.01084  [pdf, other

    hep-ex astro-ph.CO astro-ph.SR physics.ins-det

    First Results on the Search for Chameleons with the KWISP Detector at CAST

    Authors: S. Arguedas Cuendis, J. Baier, K. Barth, S. Baum, A. Bayirli, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, J. F. Castel, S. A. Cetin, T. Dafni, M. Davenport, A. Dermenev, K. Desch, B. Döbrich, H. Fischer, W. Funk, J. A. García, A. Gardikiotis, J. G. Garza, S. Gninenko, M. D. Hasinoff, D. H. H. Hoffmann, F. J. Iguaz , et al. (28 additional authors not shown)

    Abstract: We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of… ▽ More

    Submitted 3 June, 2019; originally announced June 2019.

    Comments: 21 pages, 12 figures

  5. arXiv:1812.04519  [pdf, other

    astro-ph.IM astro-ph.GA hep-ex physics.ins-det

    Background assessment for the TREX Dark Matter experiment

    Authors: J. Castel, S. Cebrian, I. Coarasa, T. Dafni, J. Galan, F. J. Iguaz, I. G. Irastorza, G. Luzon, H. Mirallas, A. Ortiz de Solorzano, E. Ruiz-Choliz

    Abstract: TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing… ▽ More

    Submitted 22 September, 2019; v1 submitted 11 December, 2018; originally announced December 2018.

    Comments: Final version, as accepted in Eur. Phys. J. C

    Journal ref: Eur. Phys. J. C 79 (2019) 782

  6. arXiv:1811.09290  [pdf, other

    hep-ph astro-ph.CO

    Weighing the Solar Axion

    Authors: Theopisti Dafni, Ciaran A. J. O'Hare, Biljana Lakić, Javier Galán, Francisco J. Iguaz, Igor G. Irastorza, Krešimir Jakovčić, Gloria Luzón, Javier Redondo, Elisa Ruiz Chóliz

    Abstract: Axion helioscopes search for solar axions and axion-like particles via inverse Primakoff conversion in strong laboratory magnets pointed at the Sun. While helioscopes can always measure the axion coupling to photons, the conversion signal is independent of the mass for axions lighter than around 0.02 eV. Masses above this value on the other hand have suppressed signals due to axion-photon oscillat… ▽ More

    Submitted 20 February, 2019; v1 submitted 22 November, 2018; originally announced November 2018.

    Comments: 13 pages, 7 figures, matches published version, code available at http://cajohare.github.io/IAXOmass

    Journal ref: Phys. Rev. D 99, 035037 (2019)

  7. arXiv:1706.05818  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    Cosmogenic production of tritium in dark matter detectors

    Authors: J. Amare, J. Castel, S. Cebrian, I. Coarasa, C. Cuesta, T. Dafni, J. Galan, E. Garcia, J. G. Garza, F. J. Iguaz, I. G. Irastorza, G. Luzon, M. Martinez, H. Mirallas, M. A. Olivan, Y. Ortigoza, A. Ortiz de Solorzano, J. Puimedon, E. Ruiz-Choliz, M. L. Sarsa, J. A. Villar, P. Villar

    Abstract: The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and… ▽ More

    Submitted 24 November, 2017; v1 submitted 19 June, 2017; originally announced June 2017.

    Comments: Final version as published

    Journal ref: Astroparticle Physics 97 (2018) 96-105

  8. arXiv:1509.06190  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research

    Authors: F. Aznar, J. Castel, F. E. Christensen, T. Dafni, T. A. Decker, E. Ferrer-Ribas, J. A. Garcia, I. Giomataris, J. G. Gracia, C. J. Hailey, R. M. Hill, F. J. Iguaz, I. G. Irastorza, A. C. Jakobsen, G. Luzon, H. Mirallas, T. Papaevangelou, M. J. Pivovaroff, J. Ruz, T. Vafeiadis, J. K. Vogel

    Abstract: We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed… ▽ More

    Submitted 21 September, 2015; originally announced September 2015.

    Comments: 21 pages, 16 figures

  9. arXiv:1508.03006  [pdf, other

    astro-ph.IM physics.ins-det

    Exploring 0.1-10$\,$eV axions with a new helioscope concept

    Authors: J. Galán, T. Dafni, E. Ferrer-Ribas, I. Giomataris, F. J. Iguaz, I. G. Irastorza, J. A. García, J. Gracia, G. Luzón, T. Papaevangelou, J. Redondo, A. Tomás

    Abstract: We explore the possibility to develop a new axion helioscope type, sensitive to the higher axion mass region favored by axion models. We propose to use a low background large volume TPC immersed in an intense magnetic field. Contrary to traditional tracking helioscopes, this detection technique takes advantage of the capability to directly detect the photons converted on the buffer gas which defin… ▽ More

    Submitted 7 September, 2015; v1 submitted 12 August, 2015; originally announced August 2015.

    Comments: prepared for submission to JCAP

  10. arXiv:1503.04561  [pdf, other

    astro-ph.SR hep-ph physics.ins-det

    Search for chameleons with CAST

    Authors: V. Anastassopoulos, M. Arik, S. Aune, K. Barth, A. Belov, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, F. Christensen, J. I. Collar, T. Dafni, M. Davenport, K. Desch, A. Dermenev, C. Eleftheriadis, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis , et al. (39 additional authors not shown)

    Abstract: In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to… ▽ More

    Submitted 18 March, 2016; v1 submitted 16 March, 2015; originally announced March 2015.

    Comments: 8 pages, 12 figures

  11. arXiv:1501.01626  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Characterization of a Spherical Proportional Counter in argon-based mixtures

    Authors: F. J. Iguaz, A. Rodriguez, J. F. Castel, I. G. Irastorza

    Abstract: The Spherical Proportional Counter is a novel type of radiation detector, with a low energy threshold (typically below 100 eV) and good energy resolution. This detector is being developed by the network NEWS, which includes several applications. We can name between many others Dark Matter searches, low level radon and neutron counting or low energy neutrino detection from supernovas or nuclear rea… ▽ More

    Submitted 7 January, 2015; originally announced January 2015.

    Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)

    Journal ref: PoS(TIPP2014) 162

  12. arXiv:1501.01466  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches

    Authors: F. J. Iguaz, S. Aune, F. Aznar, J. F. Castel, T. Dafni, M. Davenport, E. Ferrer-Ribas, J. Galan, J. A. Garcia, J. G. Garza, I. Giomataris, I. G. Irastorza, T. Papaevangelou, A. Rodriguez, A. Tomas, T. Vafeiadis, S. C. Yildiz

    Abstract: Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observ… ▽ More

    Submitted 7 January, 2015; originally announced January 2015.

    Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)

    Journal ref: Pos(TIPP2014) 295

  13. arXiv:1501.01456  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Axion helioscopes update: the status of CAST and IAXO

    Authors: T. Dafni, F. J. Iguaz

    Abstract: Almost 35 years since their suggestion as a good solution to the strong CP-problem, axions remain one of the few viable candidates for the Dark Matter, although still eluding detection. Most of the methods for their detection are based on their coupling to photons, one of the most sensitive ones being the helioscope technique. We report on the current status of the CERN Axion Solar Telescope and t… ▽ More

    Submitted 7 January, 2015; originally announced January 2015.

    Comments: Proceedings of 3rd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2014)

    Journal ref: PoS(TIPP2014) 130

  14. arXiv:1401.1009  [pdf, ps, other

    astro-ph.IM physics.ins-det

    Measurement of the electron drift velocity for directional dark matter detectors

    Authors: F. Mayet, J. Billard, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by sim… ▽ More

    Submitted 6 January, 2014; originally announced January 2014.

    Comments: Proceedings of the 4th international conference on Directional Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japan

    Report number: in2p3-00845411

    Journal ref: J. Phys. Conf. Ser. 469 (2013) 012006

  15. arXiv:1307.1985  [pdf, ps, other

    hep-ex astro-ph.IM physics.ins-det

    CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap

    Authors: M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Brauninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, E. Da Riva, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, G. Fanourakis, E. Ferrer-Ribas, P. Friedrich, J. Galan, J. A. Garcia, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, E. Georgiopoulou , et al. (50 additional authors not shown)

    Abstract: The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}… ▽ More

    Submitted 15 September, 2014; v1 submitted 8 July, 2013; originally announced July 2013.

    Comments: 5 pages, 2 figures. Last version uploaded

    Journal ref: Phys. Rev. Lett. 112, 091302 (2014)

  16. arXiv:1305.2360  [pdf, ps, other

    astro-ph.IM physics.ins-det

    In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors

    Authors: J. Billard, F. Mayet, G. Bosson, O. Bourrion, O. Guillaudin, J. Lamblin, J. P. Richer, Q. Riffard, D. Santos, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by… ▽ More

    Submitted 28 January, 2014; v1 submitted 10 May, 2013; originally announced May 2013.

    Comments: 19 pages, 14 figures. Minor corrections, matches published version in JINST

    Journal ref: JINST 9 (2014) P01013

  17. arXiv:1304.2255  [pdf, other

    physics.ins-det astro-ph.CO

    MIMAC: A micro-tpc matrix for dark matter directional detection

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, C. Fourel, O. Guillaudin, J. Lamblin, J. F. Muraz, F. Mayet, J. P. Richer, Q. Riffard, E. Ferrer, I. Giomataris, F. J. Iguaz, L. Lebreton, D. Maire

    Abstract: The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based o… ▽ More

    Submitted 8 April, 2013; originally announced April 2013.

    Comments: Proceedings of the 6th Symposium on Large TPCs for low energy rare event detection, Paris, December 2012

  18. arXiv:1210.3287  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures

    Authors: S. Cebrián, T. Dafni, E. Ferrer-Ribas, I. Giomataris, D. Gonzalez-Diaz, H. Gómez, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzon, A. Rodríguez, L. Segui, A. Tomás

    Abstract: In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of… ▽ More

    Submitted 23 November, 2012; v1 submitted 11 October, 2012; originally announced October 2012.

  19. arXiv:1209.6347  [pdf, other

    hep-ex astro-ph.CO

    Results and perspectives of the solar axion search with the CAST experiment

    Authors: E. Ferrer-Ribas, M. Arik, S. Aune, K. Barth, A. Belov, S. Borghi, H. Bräuninger, G. Cantatore, J. M. Carmona, S. A. Cetin, J. I. Collar, T. Dafni, M. Davenport, C. Eleftheriadis, N. Elias, C. Ezer, G. Fanourakis, P. Friedrich, J. Galán, J. A. García, A. Gardikiotis, J. G. Garza, E. N. Gazis, T. Geralis, I. Giomataris , et al. (47 additional authors not shown)

    Abstract: The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV… ▽ More

    Submitted 30 October, 2012; v1 submitted 27 September, 2012; originally announced September 2012.

    Comments: 4 pages, 2 pages, to appear in the proceedings of the 24th Rencontres de Blois V2 A few affiliations were not corrected in previous version V3 Author added

  20. arXiv:1208.5690  [pdf, other

    physics.ins-det astro-ph.SR hep-ex

    CAST microbulk micromegas in the Canfranc Underground Laboratory

    Authors: A. Tomás, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. Galán, J. A. García, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gómez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, T. Papaevangelou, A. Rodríguez, J. Ruz, L. Seguí, T. Vafeiadis, S. C. Yildiz

    Abstract: During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies… ▽ More

    Submitted 28 August, 2012; originally announced August 2012.

    Comments: 6 pages, 8 figures. To appear in the proceedings of the 2nd International Conference on Technology and Instrumentation for Particle Physics (TIPP 2011)

    Journal ref: Proceedings of the 2nd International Conference on Technology and Instrumentation in Particle Physics (TIPP 2011) Volume 37, 2012, Pages 478-482

  21. arXiv:1201.3012  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Characterization of microbulk detectors in argon- and neon-based mixtures

    Authors: F. J. Iguaz, E. Ferrer-Ribas, A. Giganon, I. Giomataris

    Abstract: A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its flexible structure, low material budget and high radio-purity. Two microbulk detectors with g… ▽ More

    Submitted 14 January, 2012; originally announced January 2012.

    Comments: Submitted to the Journal of Instrumentation

  22. arXiv:1111.1566  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC: A micro-tpc matrix project for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of… ▽ More

    Submitted 7 November, 2011; originally announced November 2011.

    Comments: Proceedings of the 3rd International Conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois- France- June 2011

  23. arXiv:1110.2608  [pdf, other

    physics.ins-det astro-ph.IM

    Low X-ray bakground measurements at the Underground Canfranc Laboratory

    Authors: J. Galan, S. Aune, T. Dafni, G. Fanourakis, E. Ferrer-Ribas, J. A. Garcia, A. Gardikiotis, T. Geralis, I. Giomataris, H. Gomez, J. G. Garza, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzon, T. Papaevangelou, A. Rodriguez, J. Ruz, L. Segui, A. Tomas, T. Vafeiadis, S. C. Yildiz

    Abstract: Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Undergrou… ▽ More

    Submitted 25 October, 2011; v1 submitted 12 October, 2011; originally announced October 2011.

    Comments: Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011

  24. arXiv:1109.1675  [pdf, other

    physics.ins-det astro-ph.IM

    Micromegas detector developments for MIMAC

    Authors: E. Ferrer-Ribas, D. Attié, D. Calvet, P. Colas, F. Druillole, Y. Giomataris, F. J. Iguaz, J. P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, D. Santos, C. Golabek, L. Lebreton

    Abstract: The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.

    Submitted 12 September, 2011; v1 submitted 8 September, 2011; originally announced September 2011.

    Comments: 8 pages, 7 figures Proceedings of the 3rd International conference on Directional Detection of Dark Matter (CYGNUS 2011), Aussois, France, 8-10 June 2011; corrections on author affiliations

  25. MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, J. L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, A. Delbart, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. T… ▽ More

    Submitted 16 February, 2011; originally announced February 2011.

    Comments: 6 pages, Proc. of the fifth international symposium on large TPCs for low energy rare event detection, Paris, France, Dec. 2010. To appear in Journal of Physics

    Report number: LPSC10223

    Journal ref: J.Phys.Conf.Ser. 309 (2011) 012014

  26. arXiv:1012.1166  [pdf, ps, other

    astro-ph.IM astro-ph.CO

    MIMAC : A micro-tpc matrix for directional detection of dark matter

    Authors: D. Santos, J. Billard, G. Bosson, O. Bourrion, C. Grignon, O. Guillaudin, F. Mayet, J. P. Richer, E. Ferrer, I. Giomataris, F. J. Iguaz, J. P. Mols, A. Allaoua, C. Golabek, L. Lebreton

    Abstract: Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or… ▽ More

    Submitted 6 December, 2010; originally announced December 2010.

    Comments: Proceedings of Identification of Dark Matter 2010-IDM2010 conference

  27. arXiv:1009.1827  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex

    Micromegas readouts for double beta decay searches

    Authors: S. Cebrián, T. Dafni, E. Ferrer-Ribas, J. Galán, J. A. García, I. Giomataris, H. Gómez, D. C. Herrera, F. J. Iguaz, I. G. Irastorza, G. Luzón, A. Rodríguez, L. Seguí, A. Tomás

    Abstract: Double beta $ββ$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0νββ$ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the… ▽ More

    Submitted 9 September, 2010; originally announced September 2010.

    Comments: 15 pages, 11 figures. Accepted for publication in JCAP

    Journal ref: JCAP 1010:010,2010

  28. The case for a directional dark matter detector and the status of current experimental efforts

    Authors: S. Ahlen, N. Afshordi, J. B. R. Battat, J. Billard, N. Bozorgnia, S. Burgos, T. Caldwell, J. M. Carmona, S. Cebrian, P. Colas, T. Dafni, E. Daw, D. Dujmic, A. Dushkin, W. Fedus, E. Ferrer, D. Finkbeiner, P. H. Fisher, J. Forbes, T. Fusayasu, J. Galan, T. Gamble, C. Ghag, I. Giomataris, M. Gold , et al. (87 additional authors not shown)

    Abstract: We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's stat… ▽ More

    Submitted 1 November, 2009; originally announced November 2009.

    Comments: 48 pages, 37 figures, whitepaper on direct dark matter detection with directional sensitivity

    Journal ref: Int.J.Mod.Phys.A25:1-51,2010