-
The International Axion Observatory (IAXO): case, status and plans. Input to the European Strategy for Particle Physics
Authors:
A. Arcusa,
S. Ahyoune,
K. Altenmuller,
I. Antolin,
S. Basso,
P. Brun,
V. Burwitz,
F. R. Candon,
J. F. Castel,
S. Cebrian,
D. Chouhan,
R. Della Ceca,
M. Cervera-Cortes,
M. M. Civitani,
C. Cogollos,
E. Costa,
V. Cotroneo,
T. Dafni,
K. Desch,
M. C. Diaz-Martin,
A. Diaz-Morcillo,
D. Diez-Ibanez,
C. Diez Pardos,
M. Dinter,
B. Dobrich
, et al. (98 additional authors not shown)
Abstract:
The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to search for solar axions with unprecedented sensitivity. IAXO holds a unique position in the global landscape of axion searches, as it will probe a region of the axion parameter space inaccessible to any other experiment. In particular, it will explore QCD axion models in the mass range from meV to eV, cove…
▽ More
The International Axion Observatory (IAXO) is a next-generation axion helioscope designed to search for solar axions with unprecedented sensitivity. IAXO holds a unique position in the global landscape of axion searches, as it will probe a region of the axion parameter space inaccessible to any other experiment. In particular, it will explore QCD axion models in the mass range from meV to eV, covering scenarios motivated by astrophysical observations and potentially extending to axion dark matter models. Several studies in recent years have demonstrated that IAXO has the potential to probe a wide range of new physics beyond solar axions, including dark photons, chameleons, gravitational waves, and axions from nearby supernovae. IAXO will build upon the two-decade experience gained with CAST, the detailed studies for BabyIAXO, which is currently under construction, as well as new technologies. If, in contrast to expectations, solar axion searches with IAXO ``only'' result in limits on new physics in presently uncharted parameter territory, these exclusions would be very robust and provide significant constraints on models, as they would not depend on untestable cosmological assumptions.
△ Less
Submitted 31 March, 2025;
originally announced April 2025.
-
An accurate solar axions ray-tracing response of BabyIAXO
Authors:
S. Ahyoune,
K. Altenmueller,
I. Antolin,
S. Basso,
P. Brun,
F. R. Candon,
J. F. Castel,
S. Cebrian,
D. Chouhan,
R. Della Ceca,
M. Cervera-Cortes,
V. Chernov,
M. M. Civitani,
C. Cogollos,
E. Costa,
V. Cotroneo,
T. Dafni,
A. Derbin,
K. Desch,
M. C. Diaz-Martin,
A. Diaz-Morcillo,
D. Diez-Ibanez,
C. Diez Pardos,
M. Dinter,
B. Doebrich
, et al. (102 additional authors not shown)
Abstract:
BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at th…
▽ More
BabyIAXO is the intermediate stage of the International Axion Observatory (IAXO) to be hosted at DESY. Its primary goal is the detection of solar axions following the axion helioscope technique. Axions are converted into photons in a large magnet that is pointing to the sun. The resulting X-rays are focused by appropriate X-ray optics and detected by sensitive low-background detectors placed at the focal spot. The aim of this article is to provide an accurate quantitative description of the different components (such as the magnet, optics, and X-ray detectors) involved in the detection of axions. Our efforts have focused on developing robust and integrated software tools to model these helioscope components, enabling future assessments of modifications or upgrades to any part of the IAXO axion helioscope and evaluating the potential impact on the experiment's sensitivity. In this manuscript, we demonstrate the application of these tools by presenting a precise signal calculation and response analysis of BabyIAXO's sensitivity to the axion-photon coupling. Though focusing on the Primakoff solar flux component, our virtual helioscope model can be used to test different production mechanisms, allowing for direct comparisons within a unified framework.
△ Less
Submitted 29 November, 2024; v1 submitted 21 November, 2024;
originally announced November 2024.
-
Conceptual Design of BabyIAXO, the intermediate stage towards the International Axion Observatory
Authors:
A. Abeln,
K. Altenmüller,
S. Arguedas Cuendis,
E. Armengaud,
D. Attié,
S. Aune,
S. Basso,
L. Bergé,
B. Biasuzzi,
P. T. C. Borges De Sousa,
P. Brun,
N. Bykovskiy,
D. Calvet,
J. M. Carmona,
J. F. Castel,
S. Cebrián,
V. Chernov,
F. E. Christensen,
M. M. Civitani,
C. Cogollos,
T. Dafní,
A. Derbin,
K. Desch,
D. Díez,
M. Dinter
, et al. (101 additional authors not shown)
Abstract:
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for…
▽ More
This article describes BabyIAXO, an intermediate experimental stage of the International Axion Observatory (IAXO), proposed to be sited at DESY. IAXO is a large-scale axion helioscope that will look for axions and axion-like particles (ALPs), produced in the Sun, with unprecedented sensitivity. BabyIAXO is conceived to test all IAXO subsystems (magnet, optics and detectors) at a relevant scale for the final system and thus serve as prototype for IAXO, but at the same time as a fully-fledged helioscope with relevant physics reach itself, and with potential for discovery. The BabyIAXO magnet will feature two 10 m long, 70 cm diameter bores, and will host two detection lines (optics and detector) of dimensions similar to the final ones foreseen for IAXO. BabyIAXO will detect or reject solar axions or ALPs with axion-photon couplings down to $g_{aγ} \sim 1.5 \times 10^{-11}$ GeV$^{-1}$, and masses up to $m_a\sim 0.25$ eV. BabyIAXO will offer additional opportunities for axion research in view of IAXO, like the development of precision x-ray detectors to identify particular spectral features in the solar axion spectrum, and the implementation of radiofrequency-cavity-based axion dark matter setups.
△ Less
Submitted 4 March, 2021; v1 submitted 22 October, 2020;
originally announced October 2020.
-
First Results on the Search for Chameleons with the KWISP Detector at CAST
Authors:
S. Arguedas Cuendis,
J. Baier,
K. Barth,
S. Baum,
A. Bayirli,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
J. F. Castel,
S. A. Cetin,
T. Dafni,
M. Davenport,
A. Dermenev,
K. Desch,
B. Döbrich,
H. Fischer,
W. Funk,
J. A. García,
A. Gardikiotis,
J. G. Garza,
S. Gninenko,
M. D. Hasinoff,
D. H. H. Hoffmann,
F. J. Iguaz
, et al. (28 additional authors not shown)
Abstract:
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of…
▽ More
We report on a first measurement with a sensitive opto-mechanical force sensor designed for the direct detection of coupling of real chameleons to matter. These dark energy candidates could be produced in the Sun and stream unimpeded to Earth. The KWISP detector installed on the CAST axion search experiment at CERN looks for tiny displacements of a thin membrane caused by the mechanical effect of solar chameleons. The displacements are detected by a Michelson interferometer with a homodyne readout scheme. The sensor benefits from the focusing action of the ABRIXAS X-ray telescope installed at CAST, which increases the chameleon flux on the membrane. A mechanical chopper placed between the telescope output and the detector modulates the incoming chameleon stream. We present the results of the solar chameleon measurements taken at CAST in July 2017, setting an upper bound on the force acting on the membrane of $80$~pN at 95\% confidence level. The detector is sensitive for direct coupling to matter $10^4 \leqβ_m \leq 10^8$, where the coupling to photons is locally bound to $β_γ\leq 10^{11}$.
△ Less
Submitted 3 June, 2019;
originally announced June 2019.
-
Background assessment for the TREX Dark Matter experiment
Authors:
J. Castel,
S. Cebrian,
I. Coarasa,
T. Dafni,
J. Galan,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
H. Mirallas,
A. Ortiz de Solorzano,
E. Ruiz-Choliz
Abstract:
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing…
▽ More
TREX-DM is conceived to look for low-mass Weakly Interacting Massive Particles (WIMPs) using a gas Time Projection Chamber equipped with micromegas readout planes at the Canfranc Underground Laboratory. The detector can hold in the active volume 20 l of pressurized gas up to 10 bar, corresponding to 0.30 kg of Ar or 0.16 kg of Ne. The micromegas are read with a self-triggered acquisition, allowing for thresholds below 0.4 keV (electron equivalent). A low background level in the lowest energy region is another essential requirement. To assess the expected background, all the relevant sources have been considered, including the measured fluxes of gamma radiation, muons and neutrons at the Canfranc Laboratory, together with the activity of most of the components used in the detector and ancillary systems, obtained in a complete assay program. The background contributions have been simulated by means of a dedicated application based on Geant4 and a custom-made code for the detector response. The background model developed for the detector presently installed in Canfranc points to levels from 1 to 10 counts keV-1 kg-1 d-1 in the region of interest, making TREX-DM competitive in the search for low-mass WIMPs. A roadmap to further decrease it down to 0.1 counts keV-1 kg-1 d-1 is underway.
△ Less
Submitted 22 September, 2019; v1 submitted 11 December, 2018;
originally announced December 2018.
-
Weighing the Solar Axion
Authors:
Theopisti Dafni,
Ciaran A. J. O'Hare,
Biljana Lakić,
Javier Galán,
Francisco J. Iguaz,
Igor G. Irastorza,
Krešimir Jakovčić,
Gloria Luzón,
Javier Redondo,
Elisa Ruiz Chóliz
Abstract:
Axion helioscopes search for solar axions and axion-like particles via inverse Primakoff conversion in strong laboratory magnets pointed at the Sun. While helioscopes can always measure the axion coupling to photons, the conversion signal is independent of the mass for axions lighter than around 0.02 eV. Masses above this value on the other hand have suppressed signals due to axion-photon oscillat…
▽ More
Axion helioscopes search for solar axions and axion-like particles via inverse Primakoff conversion in strong laboratory magnets pointed at the Sun. While helioscopes can always measure the axion coupling to photons, the conversion signal is independent of the mass for axions lighter than around 0.02 eV. Masses above this value on the other hand have suppressed signals due to axion-photon oscillations which destroy the coherence of the conversion along the magnet. However, the spectral oscillations present in the axion conversion signal between these two regimes are highly dependent on the axion mass. We show that these oscillations are observable given realistic energy resolutions and can be used to determine the axion mass to within percent level accuracies. Using projections for the upcoming helioscope IAXO, we demonstrate that $>3σ$ sensitivity to a non-zero axion mass is possible between $3 \times 10^{-3}$ and $10^{-1}$ eV for both the Primakoff and axion-electron solar fluxes.
△ Less
Submitted 20 February, 2019; v1 submitted 22 November, 2018;
originally announced November 2018.
-
Cosmogenic production of tritium in dark matter detectors
Authors:
J. Amare,
J. Castel,
S. Cebrian,
I. Coarasa,
C. Cuesta,
T. Dafni,
J. Galan,
E. Garcia,
J. G. Garza,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
M. Martinez,
H. Mirallas,
M. A. Olivan,
Y. Ortigoza,
A. Ortiz de Solorzano,
J. Puimedon,
E. Ruiz-Choliz,
M. L. Sarsa,
J. A. Villar,
P. Villar
Abstract:
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and…
▽ More
The direct detection of dark matter particles requires ultra-low background conditions at energies below a few tens of keV. Radioactive isotopes are produced via cosmogenic activation in detectors and other materials and those isotopes constitute a background source which has to be under control. In particular, tritium is specially relevant due to its decay properties (very low endpoint energy and long half-life) when induced in the detector medium, and because it can be generated in any material as a spallation product. Quantification of cosmogenic production of tritium is not straightforward, neither experimentally nor by calculations. In this work, a method for the calculation of production rates at sea level has been developed and applied to some of the materials typically used as targets in dark matter detectors (germanium, sodium iodide, argon and neon); it is based on a selected description of tritium production cross sections over the entire energy range of cosmic nucleons. Results have been compared to available data in the literature, either based on other calculations or from measurements. The obtained tritium production rates, ranging from a few tens to a few hundreds of nuclei per kg and per day at sea level, point to a significant contribution to the background in dark matter experiments, requiring the application of specific protocols for target material purification, material storing underground and limiting the time the detector is on surface during the building process in order to minimize the exposure to the most dangerous cosmic ray components.
△ Less
Submitted 24 November, 2017; v1 submitted 19 June, 2017;
originally announced June 2017.
-
A Micromegas-based low-background x-ray detector coupled to a slumped-glass telescope for axion research
Authors:
F. Aznar,
J. Castel,
F. E. Christensen,
T. Dafni,
T. A. Decker,
E. Ferrer-Ribas,
J. A. Garcia,
I. Giomataris,
J. G. Gracia,
C. J. Hailey,
R. M. Hill,
F. J. Iguaz,
I. G. Irastorza,
A. C. Jakobsen,
G. Luzon,
H. Mirallas,
T. Papaevangelou,
M. J. Pivovaroff,
J. Ruz,
T. Vafeiadis,
J. K. Vogel
Abstract:
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed…
▽ More
We report on the design, construction and operation of a low background x-ray detection line composed of a shielded Micromegas (micromesh gaseous structure) detector of the microbulk technique. The detector is made from radiopure materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of thermally-formed (or "slumped") glass substrates deposited with multilayer coatings. The system has been conceived as a technological pathfinder for the future International Axion Observatory (IAXO), as it combines two of the techniques (optic and detector) proposed in the conceptual design of the project. It is innovative for two reasons: it is the first time an x-ray optic has been designed and fabricated specifically for axion research, and the first time a Micromegas detector has been operated with an x-ray optic. The line has been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and is currently looking for solar axions. The combination of the XRT and Micromegas detector provides the best signal-to-noise ratio obtained so far by any detection system of the CAST experiment with a background rate of 5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and signal spot area.
△ Less
Submitted 21 September, 2015;
originally announced September 2015.
-
Exploring 0.1-10$\,$eV axions with a new helioscope concept
Authors:
J. Galán,
T. Dafni,
E. Ferrer-Ribas,
I. Giomataris,
F. J. Iguaz,
I. G. Irastorza,
J. A. García,
J. Gracia,
G. Luzón,
T. Papaevangelou,
J. Redondo,
A. Tomás
Abstract:
We explore the possibility to develop a new axion helioscope type, sensitive to the higher axion mass region favored by axion models. We propose to use a low background large volume TPC immersed in an intense magnetic field. Contrary to traditional tracking helioscopes, this detection technique takes advantage of the capability to directly detect the photons converted on the buffer gas which defin…
▽ More
We explore the possibility to develop a new axion helioscope type, sensitive to the higher axion mass region favored by axion models. We propose to use a low background large volume TPC immersed in an intense magnetic field. Contrary to traditional tracking helioscopes, this detection technique takes advantage of the capability to directly detect the photons converted on the buffer gas which defines the axion mass sensitivity region, and does not require pointing the magnet to the Sun. The operation flexibility of a TPC to be used with different gas mixtures (He, Ne, Xe, etc) and pressures (from 10 mbar to 10 bar) will allow to enhance sensitivity for axion masses from few meV to several eV. We present different helioscope data taking scenarios, considering detection efficiency and axion absorption probability, and show the sensitivities reachable with this technique to be few $\times$ 10$^{-11}\,$GeV$^{-1}$ for a 5$\,$T$\,$m$^3$ scale TPC. We show that a few years program taking data with such setup would allow to probe the KSVZ axion model for axion masses above 100 meV.
△ Less
Submitted 7 September, 2015; v1 submitted 12 August, 2015;
originally announced August 2015.
-
Search for chameleons with CAST
Authors:
V. Anastassopoulos,
M. Arik,
S. Aune,
K. Barth,
A. Belov,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
F. Christensen,
J. I. Collar,
T. Dafni,
M. Davenport,
K. Desch,
A. Dermenev,
C. Eleftheriadis,
G. Fanourakis,
E. Ferrer-Ribas,
P. Friedrich,
J. Galán,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis
, et al. (39 additional authors not shown)
Abstract:
In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to…
▽ More
In this work we present a search for (solar) chameleons with the CERN Axion Solar Telescope (CAST). This novel experimental technique, in the field of dark energy research, exploits both the chameleon coupling to matter ($β_{\rm m}$) and to photons ($β_γ$) via the Primakoff effect. By reducing the X-ray detection energy threshold used for axions from 1$\,$keV to 400$\,$eV CAST became sensitive to the converted solar chameleon spectrum which peaks around 600$\,$eV. Even though we have not observed any excess above background, we can provide a 95% C.L. limit for the coupling strength of chameleons to photons of $β_γ\!\lesssim\!10^{11}$ for $1<β_{\rm m}<10^6$.
△ Less
Submitted 18 March, 2016; v1 submitted 16 March, 2015;
originally announced March 2015.
-
Characterization of a Spherical Proportional Counter in argon-based mixtures
Authors:
F. J. Iguaz,
A. Rodriguez,
J. F. Castel,
I. G. Irastorza
Abstract:
The Spherical Proportional Counter is a novel type of radiation detector, with a low energy threshold (typically below 100 eV) and good energy resolution. This detector is being developed by the network NEWS, which includes several applications. We can name between many others Dark Matter searches, low level radon and neutron counting or low energy neutrino detection from supernovas or nuclear rea…
▽ More
The Spherical Proportional Counter is a novel type of radiation detector, with a low energy threshold (typically below 100 eV) and good energy resolution. This detector is being developed by the network NEWS, which includes several applications. We can name between many others Dark Matter searches, low level radon and neutron counting or low energy neutrino detection from supernovas or nuclear reactors via neutrino-nucleus elastic scattering. In this context, this works will present the characterization of a spherical detector of 1 meter diameter using two argon-based mixtures (with methane and isobutane) and for gas pressures between 50 and 1250 mbar. In each case, the energy resolution shows its best value in a wide range of gains, limited by the ballistic effect at low gains and by ion-backflow at high gains. Moreover, the best energy resolution shows a degradation with pressure. These effects will be discussed in terms of gas avalanche properties. Finally, the effect of an electrical field corrector in the homogenity of the gain and the energy threshold measured in our setup will be also discussed.
△ Less
Submitted 7 January, 2015;
originally announced January 2015.
-
Lowering the background level and the energy threshold of Micromegas x-ray detectors for axion searches
Authors:
F. J. Iguaz,
S. Aune,
F. Aznar,
J. F. Castel,
T. Dafni,
M. Davenport,
E. Ferrer-Ribas,
J. Galan,
J. A. Garcia,
J. G. Garza,
I. Giomataris,
I. G. Irastorza,
T. Papaevangelou,
A. Rodriguez,
A. Tomas,
T. Vafeiadis,
S. C. Yildiz
Abstract:
Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observ…
▽ More
Axion helioscopes search for solar axions by their conversion in x-rays in the presence of high magnetic fields. The use of low background x-ray detectors is an essential component contributing to the sensitivity of these searches. In this work, we review the recent advances on Micromegas detectors used in the CERN Axion Solar Telescope (CAST) and proposed for the future International Axion Observatory (IAXO). The actual setup in CAST has achieved background levels below 10$^{-6}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$, a factor 100 lower than the first generation of Micromegas detectors. This reduction is based on active and passive shielding techniques, the selection of radiopure materials, offline discrimination techniques and the high granularity of the readout. We describe in detail the background model of the detector, based on its operation at CAST site and at the Canfranc Underground Laboratory (LSC), as well as on Geant4 simulations. The best levels currently achieved at LSC are low than 10$^{-7}$ keV$^{-1}$ cm$^{-2}$ s$^{-1}$ and show good prospects for the application of this technology in IAXO. Finally, we present some ideas and results for reducing the energy threshold of these detectors below 1 keV, using high-transparent windows, autotrigger electronics and studying the cluster shape at different energies. As a high flux of axion-like-particles is expected in this energy range, a sub-keV threshold detector could enlarge the physics case of axion helioscopes.
△ Less
Submitted 7 January, 2015;
originally announced January 2015.
-
Axion helioscopes update: the status of CAST and IAXO
Authors:
T. Dafni,
F. J. Iguaz
Abstract:
Almost 35 years since their suggestion as a good solution to the strong CP-problem, axions remain one of the few viable candidates for the Dark Matter, although still eluding detection. Most of the methods for their detection are based on their coupling to photons, one of the most sensitive ones being the helioscope technique. We report on the current status of the CERN Axion Solar Telescope and t…
▽ More
Almost 35 years since their suggestion as a good solution to the strong CP-problem, axions remain one of the few viable candidates for the Dark Matter, although still eluding detection. Most of the methods for their detection are based on their coupling to photons, one of the most sensitive ones being the helioscope technique. We report on the current status of the CERN Axion Solar Telescope and the future International Axion Observatory (IAXO). Recent results from the second part of CAST phase II, where the magnet bores were filled with 3He gas at variable pressure achieving sensibilities on the axion mass up to 1.2 eV, are presented. Currently, CAST is expecting to improve its sensitivity to solar axions with rest mass below 0.02 eV/c^2 after the upgrade of the X-ray detectors and with the implementation of a second X-ray optic. At the same time, it is exploring other possibilities at the low energy physics frontier. On the other hand IAXO, the fourth generation axion helioscope, aims to improve CAST's performance in terms of axion-photon coupling by 1-1.5 orders of magnitude. The details of the project building a dedicated magnet, optics and X-ray detectors are given.
△ Less
Submitted 7 January, 2015;
originally announced January 2015.
-
Measurement of the electron drift velocity for directional dark matter detectors
Authors:
F. Mayet,
J. Billard,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
J. P. Richer,
Q. Riffard,
D. Santos,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by sim…
▽ More
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection. It requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures : $\rm CF_4$ and $\rm CF_4+CHF_3$. We also show that adding $\rm CHF_3$ allows us to lower the electron drift velocity while keeping almost the same Fluorine content of the gas mixture.
△ Less
Submitted 6 January, 2014;
originally announced January 2014.
-
CAST solar axion search with 3^He buffer gas: Closing the hot dark matter gap
Authors:
M. Arik,
S. Aune,
K. Barth,
A. Belov,
S. Borghi,
H. Brauninger,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
J. I. Collar,
E. Da Riva,
T. Dafni,
M. Davenport,
C. Eleftheriadis,
N. Elias,
G. Fanourakis,
E. Ferrer-Ribas,
P. Friedrich,
J. Galan,
J. A. Garcia,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis,
E. Georgiopoulou
, et al. (50 additional authors not shown)
Abstract:
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10}…
▽ More
The CERN Axion Solar Telescope (CAST) has finished its search for solar axions with 3^He buffer gas, covering the search range 0.64 eV < m_a <1.17 eV. This closes the gap to the cosmological hot dark matter limit and actually overlaps with it. From the absence of excess X-rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g_ag < 3.3 x 10^{-10} GeV^{-1} at 95% CL, with the exact value depending on the pressure setting. Future direct solar axion searches will focus on increasing the sensitivity to smaller values of g_a, for example by the currently discussed next generation helioscope IAXO.
△ Less
Submitted 15 September, 2014; v1 submitted 8 July, 2013;
originally announced July 2013.
-
In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors
Authors:
J. Billard,
F. Mayet,
G. Bosson,
O. Bourrion,
O. Guillaudin,
J. Lamblin,
J. P. Richer,
Q. Riffard,
D. Santos,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by…
▽ More
Three-dimensional track reconstruction is a key issue for directional Dark Matter detection and it requires a precise knowledge of the electron drift velocity. Magboltz simulations are known to give a good evaluation of this parameter. However, large TPC operated underground on long time scale may be characterized by an effective electron drift velocity that may differ from the value evaluated by simulation. In situ measurement of this key parameter is hence needed as it is a way to avoid bias in the 3D track reconstruction. We present a dedicated method for the measurement of the electron drift velocity with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3. The latter has been chosen for the MIMAC detector as we expect that adding CHF3 to pure CF4 will lower the electron drift velocity. This is a key point for directional Dark Matter as the track sampling along the drift field will be improved while keeping almost the same Fluorine content of the gas mixture. We show that the drift velocity at 50 mbar is reduced by a factor of about 5 when adding 30% of CHF3.
△ Less
Submitted 28 January, 2014; v1 submitted 10 May, 2013;
originally announced May 2013.
-
MIMAC: A micro-tpc matrix for dark matter directional detection
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
C. Fourel,
O. Guillaudin,
J. Lamblin,
J. F. Muraz,
F. Mayet,
J. P. Richer,
Q. Riffard,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
L. Lebreton,
D. Maire
Abstract:
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based o…
▽ More
The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.
△ Less
Submitted 8 April, 2013;
originally announced April 2013.
-
Micromegas-TPC operation at high pressure in xenon-trimethylamine mixtures
Authors:
S. Cebrián,
T. Dafni,
E. Ferrer-Ribas,
I. Giomataris,
D. Gonzalez-Diaz,
H. Gómez,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
A. Rodríguez,
L. Segui,
A. Tomás
Abstract:
In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of…
▽ More
In this work we present a systematic study of Micromegas detectors in high pressure gaseous Xenon using trimethylamine (TMA) as quencher gas. Gas gains and energy resolutions for 22.1 keV X-rays are measured for pressures between 1 and 10 bar and various relative concentrations of TMA from 0.3 % to 15 %. We observe stable operation at all pressures, and a strongly enhanced gas gain, suggestive of Penning-like energy-transfer processes. The effect is present at all pressures and it is strongest at TMA concentrations ranging from 1.5 % to 3 %. Operating in this concentration range, the maximum gain reached values as high as x10^3 (x10^2) at 1 (10) bar. Besides, the energy resolution achievable for 22.1 keV X-rays is substantially better than the one previously obtained in pure Xe, going down to 7.3 % (9.6 %) FWHM for 1 (10) bar. These results are of interest for calorimetric applications of high pressure gas Xe TPCs, in particular for the search of the neutrinoless double beta decay of Xe-136. The resolutions achieved would extrapolate into 0.7 % (0.9 %) FWHM at the Qbb value of Xe-136 for 1 (10) bar.
△ Less
Submitted 23 November, 2012; v1 submitted 11 October, 2012;
originally announced October 2012.
-
Results and perspectives of the solar axion search with the CAST experiment
Authors:
E. Ferrer-Ribas,
M. Arik,
S. Aune,
K. Barth,
A. Belov,
S. Borghi,
H. Bräuninger,
G. Cantatore,
J. M. Carmona,
S. A. Cetin,
J. I. Collar,
T. Dafni,
M. Davenport,
C. Eleftheriadis,
N. Elias,
C. Ezer,
G. Fanourakis,
P. Friedrich,
J. Galán,
J. A. García,
A. Gardikiotis,
J. G. Garza,
E. N. Gazis,
T. Geralis,
I. Giomataris
, et al. (47 additional authors not shown)
Abstract:
The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV…
▽ More
The status of the solar axion search with the CERN Axion Solar Telescope (CAST) will be presented. Recent results obtained by the use of $^3$He as a buffer gas has allowed us to extend our sensitivity to higher axion masses than our previous measurements with $^4$He. With about 1 h of data taking at each of 252 different pressure settings we have scanned the axion mass range 0.39 eV$ \le m_{a} \le $ 0.64 eV. From the absence of an excess of x rays when the magnet was pointing to the Sun we set a typical upper limit on the axion-photon coupling of g$_{aγ} \le 2.3\times 10^{-10}$ GeV$^{-1}$ at 95% C.L., the exact value depending on the pressure setting. CAST published results represent the best experimental limit on the photon couplings to axions and other similar exotic particles dubbed WISPs (Weakly Interacting Slim Particles) in the considered mass range and for the first time the limit enters the region favored by QCD axion models. Preliminary sensitivities for axion masses up to 1.16 eV will also be shown reaching mean upper limits on the axion-photon coupling of g$_{aγ} \le 3.5\times 10^{-10}$ GeV$^{-1}$ at 95% C.L. Expected sensibilities for the extension of the CAST program up to 2014 will be presented. Moreover long term options for a new helioscope experiment will be evoked.
△ Less
Submitted 30 October, 2012; v1 submitted 27 September, 2012;
originally announced September 2012.
-
CAST microbulk micromegas in the Canfranc Underground Laboratory
Authors:
A. Tomás,
S. Aune,
T. Dafni,
G. Fanourakis,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
A. Gardikiotis,
T. Geralis,
I. Giomataris,
H. Gómez,
J. G. Garza,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
G. Luzón,
T. Papaevangelou,
A. Rodríguez,
J. Ruz,
L. Seguí,
T. Vafeiadis,
S. C. Yildiz
Abstract:
During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies…
▽ More
During the last taking data campaigns of the CAST experiment, the micromegas detectors have achieved background levels of $\approx 5 \times 10^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ between 2 and 9 keV. This performance has been possible thanks to the introduction of the microbulk technology, the implementation of a shielding and the development of discrimination algorithms. It has motivated new studies towards a deeper understanding of CAST detectors background. One of the working lines includes the construction of a replica of the set-up used in CAST by micromegas detectors and its installation in the Canfranc Underground Laboratory. Thanks to the comparison between the performance of the detectors underground and at surface, shielding upgrades, etc, different contributions to the detectors background have been evaluated. In particular, an upper limit $< 2 \times 10^{-7}$keV$^{-1}$cm$^{-2}$s$^{-1}$ for the intrinsic background of the detector has been obtained. This work means a first evaluation of the potential of the newest micromegas technology in an underground laboratory, the most suitable environment for Rare Event Searches.
△ Less
Submitted 28 August, 2012;
originally announced August 2012.
-
Characterization of microbulk detectors in argon- and neon-based mixtures
Authors:
F. J. Iguaz,
E. Ferrer-Ribas,
A. Giganon,
I. Giomataris
Abstract:
A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its flexible structure, low material budget and high radio-purity. Two microbulk detectors with g…
▽ More
A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its flexible structure, low material budget and high radio-purity. Two microbulk detectors with gaps of 50 and 25 um have been characterized in argon- and neon-based mixtures with ethane, isobutane and cyclohexane. The results will be presented and discussed. The gain curves have been fitted to the Rose-Korff gain model and dependences of the electron mean free path and the threshold energy for ionization have been obtained. The possible relation between these two parameters and the energy resolution will be also discussed.
△ Less
Submitted 14 January, 2012;
originally announced January 2012.
-
MIMAC: A micro-tpc matrix project for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
O. Guillaudin,
F. Mayet,
J. P. Richer,
A. Delbart,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of…
▽ More
Directional detection of non-baryonic DarkMatter is a promising search strategy for discriminating WIMP events from background ones. This strategy requires both a measurement of the recoil energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC project, based on a micro-TPC matrix, filled with CF4 and CHF3 is being developed. The first results of a chamber prototype of this matrix, on low energy nuclear recoils (1H and 19F) obtained with mono-energetic neutron fields are presented. The discovery potential of this search strategy is illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 7 November, 2011;
originally announced November 2011.
-
Low X-ray bakground measurements at the Underground Canfranc Laboratory
Authors:
J. Galan,
S. Aune,
T. Dafni,
G. Fanourakis,
E. Ferrer-Ribas,
J. A. Garcia,
A. Gardikiotis,
T. Geralis,
I. Giomataris,
H. Gomez,
J. G. Garza,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
G. Luzon,
T. Papaevangelou,
A. Rodriguez,
J. Ruz,
L. Segui,
A. Tomas,
T. Vafeiadis,
S. C. Yildiz
Abstract:
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Undergrou…
▽ More
Micromegas detectors, thanks to the good spatial and temporal discrimination capabilities, are good candidates for rare event search experiments. Recent X-ray background levels achieved by these detectors in the CAST experiment have motivated further studies in the nature of the background levels measured. In particular, different shielding configurations have been tested at the Canfranc Underground Laboratory, using a microbulk type detector which was previously running at the CAST experiment. The first results underground show that this technology, which is made of low radiative materials, is able to reach background levels up to $2 \times 10^{-7}$keV$^{-1}$s$^{-1}$cm$^{-2}$ with a proper shielding. Moreover, the experimental background measurements are complemented with Geant4 simulations which allow to understand the origin of the background, and to optimize future shielding set-ups.
△ Less
Submitted 25 October, 2011; v1 submitted 12 October, 2011;
originally announced October 2011.
-
Micromegas detector developments for MIMAC
Authors:
E. Ferrer-Ribas,
D. Attié,
D. Calvet,
P. Colas,
F. Druillole,
Y. Giomataris,
F. J. Iguaz,
J. P. Mols,
J. Pancin,
T. Papaevangelou,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
D. Santos,
C. Golabek,
L. Lebreton
Abstract:
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
△ Less
Submitted 12 September, 2011; v1 submitted 8 September, 2011;
originally announced September 2011.
-
MIMAC : A micro-tpc matrix for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
J. L. Bouly,
O. Bourrion,
Ch. Fourel,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
A. Delbart,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. T…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with CF4 and CHF3. The first results on low energy nuclear recoils (H, F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 16 February, 2011;
originally announced February 2011.
-
MIMAC : A micro-tpc matrix for directional detection of dark matter
Authors:
D. Santos,
J. Billard,
G. Bosson,
O. Bourrion,
C. Grignon,
O. Guillaudin,
F. Mayet,
J. P. Richer,
E. Ferrer,
I. Giomataris,
F. J. Iguaz,
J. P. Mols,
A. Allaoua,
C. Golabek,
L. Lebreton
Abstract:
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or…
▽ More
Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from background. However, this strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. To achieve this goal, the MIMAC project has been developed. It is based on a gaseous micro-TPC matrix, filled with 3He, CF4 and/or C4H10. The first results on low energy nuclear recoils (1H and 19F) obtained with a low mono-energetic neutron field are presented. The discovery potential of this search strategy is discussed and illustrated by a realistic case accessible to MIMAC.
△ Less
Submitted 6 December, 2010;
originally announced December 2010.
-
Micromegas readouts for double beta decay searches
Authors:
S. Cebrián,
T. Dafni,
E. Ferrer-Ribas,
J. Galán,
J. A. García,
I. Giomataris,
H. Gómez,
D. C. Herrera,
F. J. Iguaz,
I. G. Irastorza,
G. Luzón,
A. Rodríguez,
L. Seguí,
A. Tomás
Abstract:
Double beta $ββ$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0νββ$ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the…
▽ More
Double beta $ββ$ decay experiments are one of the most active research topics in Neutrino Physics. The measurement of the neutrinoless mode $0νββ$ could give unique information on the neutrino mass scale and nature. The current generation of experiments aims at detector target masses at the 100 kg scale, while the next generation will need to go to the ton scale in order to completely explore the inverse hierarchy models of neutrino mass. Very good energy resolutions and ultra-low background levels are the two main experimental requirements for a successful experiment. The topological information of the $ββ$ events offered by gaseous detectors like gas Time Projection Chambers (TPC) could provide a very powerful tool of signal identification and background rejection. However only recent advances in TPC readouts may assure the competitiveness of a high pressure gas TPCs for $ββ$ searches, especially regarding the required energy resolution. In this paper we present first results on energy resolution with state-of-the-art microbulk Micromesh Gas Amplification Structure (Micromegas) using a 5.5 MeV alpha source in high pressure pure xenon. Resolutions down to 2 % FWHM have been achieved for pressures up to 5 bar. These results, together with their recently measured radiopurity , prove that Micromegas readouts are not only a viable option but a very competitive one for $ββ$ searches.
△ Less
Submitted 9 September, 2010;
originally announced September 2010.
-
The case for a directional dark matter detector and the status of current experimental efforts
Authors:
S. Ahlen,
N. Afshordi,
J. B. R. Battat,
J. Billard,
N. Bozorgnia,
S. Burgos,
T. Caldwell,
J. M. Carmona,
S. Cebrian,
P. Colas,
T. Dafni,
E. Daw,
D. Dujmic,
A. Dushkin,
W. Fedus,
E. Ferrer,
D. Finkbeiner,
P. H. Fisher,
J. Forbes,
T. Fusayasu,
J. Galan,
T. Gamble,
C. Ghag,
I. Giomataris,
M. Gold
, et al. (87 additional authors not shown)
Abstract:
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's stat…
▽ More
We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.
△ Less
Submitted 1 November, 2009;
originally announced November 2009.