-
In-orbit Performance of the Soft X-ray Imaging Telescope Xtend aboard XRISM
Authors:
Hiroyuki Uchida,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroshi Murakami,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Kawabata Nobukawa,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Go Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Tessei Yoshida,
Yoshiaki Kanemaru,
Daiki Ishi,
Tadayasu Dotani
, et al. (40 additional authors not shown)
Abstract:
We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy ran…
▽ More
We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy range of 0.4--13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170--180 eV at 6 keV, which meets the mission requirement and enables to resolve He-like and H-like Fe K$α$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in SXI onboard the previous Hitomi mission -- light leakage and crosstalk events -- are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C273 results in an effective area measured to be $\sim420$ cm$^{2}[email protected] keV and $\sim310$ cm$^{2}[email protected] keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations: the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared to other major X-ray instruments onboard satellites, combined with the largest grasp ($Ω_{\rm eff}\sim60$ ${\rm cm^2~degree^2}$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.
△ Less
Submitted 25 March, 2025;
originally announced March 2025.
-
The Simons Observatory: Science Goals and Forecasts for the Enhanced Large Aperture Telescope
Authors:
The Simons Observatory Collaboration,
M. Abitbol,
I. Abril-Cabezas,
S. Adachi,
P. Ade,
A. E. Adler,
P. Agrawal,
J. Aguirre,
Z. Ahmed,
S. Aiola,
T. Alford,
A. Ali,
D. Alonso,
M. A. Alvarez,
R. An,
K. Arnold,
P. Ashton,
Z. Atkins,
J. Austermann,
S. Azzoni,
C. Baccigalupi,
A. Baleato Lizancos,
D. Barron,
P. Barry,
J. Bartlett
, et al. (397 additional authors not shown)
Abstract:
We describe updated scientific goals for the wide-field, millimeter-wave survey that will be produced by the Simons Observatory (SO). Significant upgrades to the 6-meter SO Large Aperture Telescope (LAT) are expected to be complete by 2028, and will include a doubled mapping speed with 30,000 new detectors and an automated data reduction pipeline. In addition, a new photovoltaic array will supply…
▽ More
We describe updated scientific goals for the wide-field, millimeter-wave survey that will be produced by the Simons Observatory (SO). Significant upgrades to the 6-meter SO Large Aperture Telescope (LAT) are expected to be complete by 2028, and will include a doubled mapping speed with 30,000 new detectors and an automated data reduction pipeline. In addition, a new photovoltaic array will supply most of the observatory's power. The LAT survey will cover about 60% of the sky at a regular observing cadence, with five times the angular resolution and ten times the map depth of Planck. The science goals are to: (1) determine the physical conditions in the early universe and constrain the existence of new light particles; (2) measure the integrated distribution of mass, electron pressure, and electron momentum in the late-time universe, and, in combination with optical surveys, determine the neutrino mass and the effects of dark energy via tomographic measurements of the growth of structure at $z < 3$; (3) measure the distribution of electron density and pressure around galaxy groups and clusters, and calibrate the effects of energy input from galaxy formation on the surrounding environment; (4) produce a sample of more than 30,000 galaxy clusters, and more than 100,000 extragalactic millimeter sources, including regularly sampled AGN light-curves, to study these sources and their emission physics; (5) measure the polarized emission from magnetically aligned dust grains in our Galaxy, to study the properties of dust and the role of magnetic fields in star formation; (6) constrain asteroid regoliths, search for Trans-Neptunian Objects, and either detect or eliminate large portions of the phase space in the search for Planet 9; and (7) provide a powerful new window into the transient universe on time scales of minutes to years, concurrent with observations from Rubin of overlapping sky.
△ Less
Submitted 15 March, 2025; v1 submitted 1 March, 2025;
originally announced March 2025.
-
Soft X-ray Imager of the Xtend system onboard XRISM
Authors:
Hirofumi Noda,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Go Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Tessei Yoshida,
Yoshiaki Kanemaru,
Junko Hiraga,
Tadayasu Dotani
, et al. (35 additional authors not shown)
Abstract:
The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and…
▽ More
The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and find that the CCD set employed in the Hitomi/SXI or similar, i.e., a $2 \times 2$ array of back-illuminated CCDs with a $200~μ$m-thick depletion layer, would be practically best among available choices, when used in combination with the X-ray mirror assembly. We design the XRISM/SXI, based on the Hitomi/SXI, to have a wide field of view of $38' \times 38'$ in the $0.4-13$ keV energy range. We incorporated several significant improvements from the Hitomi/SXI into the CCD chip design to enhance the optical-light blocking capability and to increase the cosmic-ray tolerance, reducing the degradation of charge-transfer efficiency in orbit. By the time of the launch of XRISM, the imaging and spectroscopic capabilities of the SXI has been extensively studied in on-ground experiments with the full flight-model configuration or equivalent setups and confirmed to meet the requirements. The optical blocking capability, the cooling and temperature control performance, and the transmissivity and quantum efficiency to incident X-rays of the CCDs are also all confirmed to meet the requirements. Thus, we successfully complete the pre-flight development of the SXI for XRISM.
△ Less
Submitted 11 February, 2025;
originally announced February 2025.
-
Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi
, et al. (38 additional authors not shown)
Abstract:
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is…
▽ More
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Initial operations of the Soft X-ray Imager onboard XRISM
Authors:
Hiromasa Suzuki,
Tomokage Yoneyama,
Shogo B. Kobayashi,
Hirofumi Noda,
Hiroyuki Uchida,
Kumiko K. Nobukawa,
Kouichi Hagino,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Yoshiaki Kanemaru,
Yoshinori Otsuka,
Haruhiko Yokosu,
Wakana Yonemaru,
Hanako Nakano,
Kazuhiro Ichikawa,
Reo Takemoto,
Tsukasa Matsushima,
Marina Yoshimoto,
Mio Aoyagi,
Kohei Shima
, et al. (30 additional authors not shown)
Abstract:
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and…
▽ More
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the small window modes, and event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.
△ Less
Submitted 14 February, 2025; v1 submitted 28 June, 2024;
originally announced June 2024.
-
Scaling slowly rotating asteroids by stellar occultations
Authors:
A. Marciniak,
J. Ďurech,
A. Choukroun,
J. Hanuš,
W. Ogłoza,
R. Szakáts,
L. Molnár,
A. Pál,
F. Monteiro,
E. Frappa,
W. Beisker,
H. Pavlov,
J. Moore,
R. Adomavičienė,
R. Aikawa,
S. Andersson,
P. Antonini,
Y. Argentin,
A. Asai,
P. Assoignon,
J. Barton,
P. Baruffetti,
K. L. Bath,
R. Behrend,
L. Benedyktowicz
, et al. (154 additional authors not shown)
Abstract:
As evidenced by recent survey results, majority of asteroids are slow rotators (P>12 h), but lack spin and shape models due to selection bias. This bias is skewing our overall understanding of the spins, shapes, and sizes of asteroids, as well as of their other properties. Also, diameter determinations for large (>60km) and medium-sized asteroids (between 30 and 60 km) often vary by over 30% for m…
▽ More
As evidenced by recent survey results, majority of asteroids are slow rotators (P>12 h), but lack spin and shape models due to selection bias. This bias is skewing our overall understanding of the spins, shapes, and sizes of asteroids, as well as of their other properties. Also, diameter determinations for large (>60km) and medium-sized asteroids (between 30 and 60 km) often vary by over 30% for multiple reasons.
Our long-term project is focused on a few tens of slow rotators with periods of up to 60 hours. We aim to obtain their full light curves and reconstruct their spins and shapes. We also precisely scale the models, typically with an accuracy of a few percent.
We used wide sets of dense light curves for spin and shape reconstructions via light-curve inversion. Precisely scaling them with thermal data was not possible here because of poor infrared data: large bodies are too bright for WISE mission. Therefore, we recently launched a campaign among stellar occultation observers, to scale these models and to verify the shape solutions, often allowing us to break the mirror pole ambiguity.
The presented scheme resulted in shape models for 16 slow rotators, most of them for the first time. Fitting them to stellar occultations resolved previous inconsistencies in size determinations. For around half of the targets, this fitting also allowed us to identify a clearly preferred pole solution, thus removing the ambiguity inherent to light-curve inversion. We also address the influence of the uncertainty of the shape models on the derived diameters.
Overall, our project has already provided reliable models for around 50 slow rotators. Such well-determined and scaled asteroid shapes will, e.g. constitute a solid basis for density determinations when coupled with mass information. Spin and shape models continue to fill the gaps caused by various biases.
△ Less
Submitted 13 October, 2023;
originally announced October 2023.
-
Localization of Vector Field on Dynamical Domain Wall
Authors:
Masafumi Higuchi,
Shin'ichi Nojiri
Abstract:
In the previous works (arXiv:1202.5375 and 1402.1346), the dynamical domain wall, where the four dimensional FRW universe is embedded in the five imensional space-time, has been realized by using two scalar fields. In this paper, we consider the localization of vector field in three formulations. The first formulation was investigated in the previous paper (arXiv:1510.01099) for the $U(1)$ gauge f…
▽ More
In the previous works (arXiv:1202.5375 and 1402.1346), the dynamical domain wall, where the four dimensional FRW universe is embedded in the five imensional space-time, has been realized by using two scalar fields. In this paper, we consider the localization of vector field in three formulations. The first formulation was investigated in the previous paper (arXiv:1510.01099) for the $U(1)$ gauge field. In the second formulation, we investigate the Dvali-Shifman mechanism (hep-th/9612128), where the non-abelian gauge field is confined in the bulk but the gauge symmetry is spontaneously broken on the domain wall. In the third formulation, we investigate the Kaluza-Klein modes coming from the five dimensional graviton. In the Randall-Sundrum model, the graviton was localized on the brane. We show that the $(5,μ)$ components $\left(μ=0,1,2,3\right)$ of the graviton are also localized on the domain wall and can be regarded as the vector field on the domain wall. There are, however, some corrections coming from the bulk extra dimension if the domain wall universe is expanding.
△ Less
Submitted 30 November, 2016;
originally announced November 2016.
-
Dynamical Domain Wall and Localization
Authors:
Yuta Toyozato,
Masafumi Higuchi,
Shin'ichi Nojiri
Abstract:
Based on the previous works (arXiv:1202.5375 and 1402.1346), we investigate the localization of the fields on the dynamical domain wall, where the four dimensional FRW universe is realized on the domain wall in the five dimensional space-time. Especially we show that the chiral spinor can localize on the domain wall, which has not been succeeded in the past works as the seminal work in arXiv:0810.…
▽ More
Based on the previous works (arXiv:1202.5375 and 1402.1346), we investigate the localization of the fields on the dynamical domain wall, where the four dimensional FRW universe is realized on the domain wall in the five dimensional space-time. Especially we show that the chiral spinor can localize on the domain wall, which has not been succeeded in the past works as the seminal work in arXiv:0810.3746.
△ Less
Submitted 17 January, 2016; v1 submitted 5 October, 2015;
originally announced October 2015.
-
Reconstruction of Domain Wall Universe and Localization of Gravity
Authors:
Masafumi Higuchi,
Shin'ichi Nojiri
Abstract:
We construct a four-dimensional domain wall universe by using the Brans-Dicke type gravity with two scalar field. We give a formulation where for arbitrarily given warp factor and scale factor, we construct an action which reproduces both of the warp and scale factors as a solution of the Einstein equation and the field equations given by the action. This formulation could be called as reconstruct…
▽ More
We construct a four-dimensional domain wall universe by using the Brans-Dicke type gravity with two scalar field. We give a formulation where for arbitrarily given warp factor and scale factor, we construct an action which reproduces both of the warp and scale factors as a solution of the Einstein equation and the field equations given by the action. This formulation could be called as reconstruction. We show that the model does not contain ghost with negative kinetic term and there occur the localization of gravity as in the Randall-Sundrum model. It should be noted that in the equation of the graviton, there appear extra terms related with the extra dimension, which might affect the tensor mode in the fluctuations
△ Less
Submitted 6 February, 2014;
originally announced February 2014.