Skip to main content

Showing 1–8 of 8 results for author: Hakamata, T

Searching in archive astro-ph. Search in all archives.
.
  1. arXiv:2505.09890  [pdf, other

    astro-ph.HE

    XRISM spectroscopy on orbital modulation of Fe Ly$α$ lines in Cygnus X-3

    Authors: Daiki Miura, Hiroya Yamaguchi, Ralf Ballhausen, Timothy Kallman, Teruaki Enoto, Shinya Yamada, Tomohiro Hakamata, Ryota Tomaru, Hirokazu Odaka, Hatalie Hell, Hiroshi Nakajima, Shin Watanabe, Tasuku Hayashi, Shunji Kitamoto, Kazutaka Yamaoka, Jon M. Miller, Keigo Okabe, Itsuki Maruzuka, Karri Koljonen, Mike McCollough

    Abstract: To understand physical processes such as mass transfer and binary evolution in X-ray binaries, the orbital parameters of the system are fundamental and crucial information. Cygnus X-3 is a high-mass X-ray binary composed of a compact object of unknown nature and a Wolf-Rayet star, which is of great interest in the context of wind-fed mass accretion and binary evolution. Here we present XRISM/Resol… ▽ More

    Submitted 14 May, 2025; originally announced May 2025.

    Comments: 10 pages, 10 figures, accepted for publication in PASJ for the XRISM special issue

  2. arXiv:2503.14307  [pdf, other

    astro-ph.HE astro-ph.IM

    XL-Calibur measurements of polarised hard X-ray emission from the Crab

    Authors: Hisamitsu Awaki, Matthew G. Baring, Richard Bose, Dana Braun, Jacob Casey, Sohee Chun, Pavel Galchenko, Ephraim Gau, Kazuho Goya, Tomohiro Hakamata, Takayuki Hayashi, Scott Heatwole, Kun Hu, Ryo Imazawa, Daiki Ishi, Manabu Ishida, Fabian Kislat, Mózsi Kiss, Kassi Klepper, Henric Krawczynski, Haruki Kuramoto, R. James Lanzi, Lindsey Lisalda, Yoshitomo Maeda, Filip af Malmborg , et al. (24 additional authors not shown)

    Abstract: We report measurements of the linear polarisation degree (PD) and angle (PA) for hard X-ray emission from the Crab pulsar and wind nebula. Measurements were made with the XL-Calibur ($\sim$15-80 keV) balloon-borne Compton-scattering polarimeter in July 2024. The polarisation parameters are determined using a Bayesian analysis of Stokes parameters obtained from X-ray scattering angles. Well-constra… ▽ More

    Submitted 18 March, 2025; originally announced March 2025.

    Comments: 8 pages, 4 figures. Accepted for publication in Monthly Notices of the Royal Astronomical Society

  3. NuSTAR detection of a hot stellar superflare with a temperature of 95 MK in hard X-rays

    Authors: Tomohiro Hakamata, Hironori Matsumoto, Hirokazu Odaka, Shinsuke Takasao

    Abstract: A search of the hard X-ray archive data of NuSTAR found a transient source, NuSTAR J230059+5857.4, during an observation of 1E 2259+586 on 2013 April 25. A multi-wavelength analysis using X-ray, optical, and IR data, mostly taken in its quiescent phase, was conducted to identify the origin of NuSTAR J230059+5857.4 and elucidate the phenomena associated with the flare activity. The results indicate… ▽ More

    Submitted 28 January, 2025; originally announced January 2025.

    Comments: 12 pages, 13 figures, accepted for publication in PASJ

  4. arXiv:2410.00632  [pdf, ps, other

    astro-ph.IM

    Multi-image x-ray interferometer module: II. Demonstration of high-resolution x-ray imaging with regular-interval coded apertures

    Authors: Kazunori Asakura, Kiyoshi Hayashida, Tomokage Yoneyama, Hirofumi Noda, Marina Yoshimoto, Tomohiro Hakamata, Hironori Matsumoto, Hiroshi Tsunemi

    Abstract: We have been developing an x-ray imaging system, Multi-Image X-ray Interferometer Module (MIXIM), to achieve a high angular resolution with a compact system size. MIXIM is comprised of a mask with equally-spaced apertures and an x-ray detector. The aperture size and mask-detector distance determine the system's angular resolution. Although a smaller aperture gives a better resolution, the degree o… ▽ More

    Submitted 1 October, 2024; originally announced October 2024.

    Comments: 27 pages, 11 figures, accepted for publication in JATIS

  5. arXiv:2409.13209  [pdf, other

    astro-ph.IM astro-ph.HE

    First operation of LArTPC in the stratosphere as an engineering GRAMS balloon flight (eGRAMS)

    Authors: R. Nakajima, S. Arai, K. Aoyama, Y. Utsumi, T. Tamba, H. Odaka, M. Tanaka, K. Yorita, S. Arai, T. Aramaki, J. Asaadi, A. Bamba, N. Cannady, P. Coppi, G. De Nolfo, M. Errando, L. Fabris, T. Fujiwara, Y. Fukazawa, P. Ghosh, K. Hagino, T. Hakamata, U. Hijikata, N. Hiroshima, M. Ichihashi , et al. (39 additional authors not shown)

    Abstract: GRAMS (Gamma-Ray and AntiMatter Survey) is a next-generation balloon/satellite experiment utilizing a LArTPC (Liquid Argon Time Projection Chamber), to simultaneously target astrophysical observations of cosmic MeV gamma-rays and conduct an indirect dark matter search using antimatter. While LArTPCs are widely used in particle physics experiments, they have never been operated at balloon altitudes… ▽ More

    Submitted 25 November, 2024; v1 submitted 20 September, 2024; originally announced September 2024.

    Journal ref: Progress of Theoretical and Experimental Physics, Volume 2024, Issue 12, December 2024, 123F01

  6. arXiv:2406.19911  [pdf, other

    astro-ph.IM

    Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)

    Authors: Koji Mori, Hiroshi Tomida, Hiroshi Nakajima, Takashi Okajima, Hirofumi Noda, Hiroyuki Uchida, Hiromasa Suzuki, Shogo Benjamin Kobayashi, Tomokage Yoneyama, Kouichi Hagino, Kumiko Nobukawa, Takaaki Tanaka, Hiroshi Murakami, Hideki Uchiyama, Masayoshi Nobukawa, Hironori Matsumoto, Takeshi Tsuru, Makoto Yamauchi, Isamu Hatsukade, Hirokazu Odaka, Takayoshi Kohmura, Kazutaka Yamaoka, Manabu Ishida, Yoshitomo Maeda, Takayuki Hayashi , et al. (38 additional authors not shown)

    Abstract: Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is… ▽ More

    Submitted 28 June, 2024; originally announced June 2024.

    Comments: 10 pages, 8 figures. Proceedings of SPIE Astronomical Telescopes and Instrumentation 2024

  7. Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)

    Authors: Koji Mori, Hiroshi Tomida, Hiroshi Nakajima, Takashi Okajima, Hirofumi Noda, Takaaki Tanaka, Hiroyuki Uchida, Kouichi Hagino, Shogo Benjamin Kobayashi, Hiromasa Suzuki, Tessei Yoshida, Hiroshi Murakami, Hideki Uchiyama, Masayoshi Nobukawa, Kumiko Nobukawa, Tomokage Yoneyama, Hironori Matsumoto, Takeshi Tsuru, Makoto Yamauchi, Isamu Hatsukade, Manabu Ishida, Yoshitomo Maeda, Takayuki Hayashi, Keisuke Tamura, Rozenn Boissay-Malaquin , et al. (30 additional authors not shown)

    Abstract: Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an… ▽ More

    Submitted 13 March, 2023; originally announced March 2023.

    Comments: 11 pages, 13 figures. Proceedings of SPIE Astronomical Telescopes and Instrumentation 2022

    Journal ref: Proc. of SPIE vol. 12181, 121811T (2022)

  8. arXiv:2212.04139  [pdf, other

    astro-ph.IM physics.ins-det

    The design and performance of the XL-Calibur anticoincidence shield

    Authors: N. K. Iyer, M. Kiss, M. Pearce, T. -A. Stana, H. Awaki, R. G. Bose, A. Dasgupta, G. De Geronimo, E. Gau, T. Hakamata, M. Ishida, K. Ishiwata, W. Kamogawa, F. Kislat, T. Kitaguchi, H. Krawczynski, L. Lisalda, Y. Maeda, H. Matsumoto, A. Miyamoto, T. Miyazawa, T. Mizuno, B. F. Rauch, N. Rodriguez Cavero, N. Sakamoto , et al. (9 additional authors not shown)

    Abstract: The XL-Calibur balloon-borne hard X-ray polarimetry mission comprises a Compton-scattering polarimeter placed at the focal point of an X-ray mirror. The polarimeter is housed within a BGO anticoincidence shield, which is needed to mitigate the considerable background radiation present at the observation altitude of ~40 km. This paper details the design, construction and testing of the anticoincide… ▽ More

    Submitted 8 December, 2022; originally announced December 2022.

    Comments: Submitted to Nuclear Instruments and Methods A

    Journal ref: Nuclear Instruments and Methods A 1048 (2023) 167975