-
X-ray spectral properties of the accreting millisecond pulsar IGR J17498-2921 during its 2023 outburst
Authors:
Giulia Illiano,
Alessandro Papitto,
Alessio Marino,
Tod E. Strohmayer,
Andrea Sanna,
Tiziana Di Salvo,
Riccardo La Placa,
Filippo Ambrosino,
Arianna Miraval Zanon,
Francesco Coti Zelati,
Caterina Ballocco,
Christian Malacaria,
Adriano Ghedina,
Massimo Cecconi,
Manuel Gonzales,
Franco Leone
Abstract:
We present a comprehensive study of the X-ray spectral properties of the accreting millisecond pulsar IGR J17498$-$2921 during its 2023 outburst. Similar to other accreting millisecond pulsars, the broad-band spectral emission observed quasi-simultaneously by NICER and NuSTAR is well described by an absorbed Comptonized emission with an electron temperature of $\sim$17 keV plus a disk reflection c…
▽ More
We present a comprehensive study of the X-ray spectral properties of the accreting millisecond pulsar IGR J17498$-$2921 during its 2023 outburst. Similar to other accreting millisecond pulsars, the broad-band spectral emission observed quasi-simultaneously by NICER and NuSTAR is well described by an absorbed Comptonized emission with an electron temperature of $\sim$17 keV plus a disk reflection component. The broadening of the disk reflection spectral features, such as a prominent iron emission line at 6.4-6.7 keV, is consistent with the relativistic motion of matter in a disk truncated at $\sim$$21 \, \mathrm{R_g}$ from the source, near the Keplerian co-rotation radius. From the high-cadence monitoring data obtained with NICER, we observe that the evolution of the photon index and the temperature of seed photons tracks variations in the X-ray flux. This is particularly evident close to a sudden $\sim$-0.25 cycles jump in the pulse phase, which occurs immediately following an X-ray flux flare and a drop in the pulse amplitude below the $3σ$ detection threshold. We also report on the non-detection of optical pulsations with TNG/SiFAP2 from the highly absorbed optical counterpart.
△ Less
Submitted 13 August, 2024;
originally announced August 2024.
-
Characterization of diamond-turned optics for SCALES
Authors:
Isabel J. Kain,
Phil Hinz,
Marius Doetz,
Benjamin Bulla,
Renate Kupke,
Daren Dillon,
Andrew Skemer,
Deno Stelter,
Michael Gonzales,
Nicholas MacDonald,
Aditi Gangadharan,
Cristian Rodriguez,
Christopher Ratliff,
Mackenzie R. Lach,
Steph Sallum
Abstract:
High-contrast imaging has been used to discover and characterize dozens of exoplanets to date. The primary limiting performance factor for these instruments is contrast, the ratio of exoplanet to host star brightness that an instrument can successfully resolve. Contrast is largely determined by wavefront error, consisting of uncorrected atmospheric turbulence and optical aberrations downstream of…
▽ More
High-contrast imaging has been used to discover and characterize dozens of exoplanets to date. The primary limiting performance factor for these instruments is contrast, the ratio of exoplanet to host star brightness that an instrument can successfully resolve. Contrast is largely determined by wavefront error, consisting of uncorrected atmospheric turbulence and optical aberrations downstream of AO correction. Single-point diamond turning allows for high-precision optics to be manufactured for use in astronomical instrumentation, presenting a cheaper and more versatile alternative to conventional glass polishing. This work presents measurements of wavefront error for diamond-turned aluminum optics in the Slicer Combined with an Array of Lenslets for Exoplanet Spectroscopy (SCALES) instrument, a 2-5 micron coronagraphic integral field spectrograph under construction for Keck Observatory. Wavefront error measurements for these optics are used to simulate SCALES' point spread function using physical optics propagation software poppy, showing that SCALES' contrast performance is not limited by wavefront error from internal instrument optics.
△ Less
Submitted 17 October, 2023;
originally announced October 2023.
-
Investigating the origin of optical and X-ray pulsations of the transitional millisecond pulsar PSR J1023+0038
Authors:
G. Illiano,
A. Papitto,
F. Ambrosino,
A. Miraval Zanon,
F. Coti Zelati,
L. Stella,
L. Zampieri,
A. Burtovoi,
S. Campana,
P. Casella,
M. Cecconi,
D. de Martino,
M. Fiori,
A. Ghedina,
M. Gonzales,
M. Hernandez Diaz,
G. L. Israel,
F. Leone,
G. Naletto,
H. Perez Ventura,
C. Riverol,
L. Riverol,
D. F. Torres,
M. Turchetta
Abstract:
PSR J1023+0038 is the first millisecond pulsar that was ever observed as an optical and UV pulsar. So far, it is the only optical transitional millisecond pulsar. The rotation- and accretion-powered emission mechanisms hardly individually explain the observed characteristics of optical pulsations. A synergistic model, combining these standard emission processes, was proposed to explain the origin…
▽ More
PSR J1023+0038 is the first millisecond pulsar that was ever observed as an optical and UV pulsar. So far, it is the only optical transitional millisecond pulsar. The rotation- and accretion-powered emission mechanisms hardly individually explain the observed characteristics of optical pulsations. A synergistic model, combining these standard emission processes, was proposed to explain the origin of the X-ray/UV/optical pulsations. We study the phase lag between the pulses in the optical and X-ray bands to gain insight into the physical mechanisms that cause it. We performed a detailed timing analysis of simultaneous or quasi-simultaneous observations in the X-ray band, acquired with the XMM-Newton and NICER satellites, and in the optical band, with the fast photometers SiFAP2 (mounted at the 3.6 m Telescopio Nazionale Galileo) and Aqueye+ (mounted at the 1.8 m Copernicus Telescope). We estimated the time lag of the optical pulsation with respect to that in the X-rays by modeling the folded pulse profiles with two harmonic components. Optical pulses lag the X-ray pulses by $\sim$ 150 $μ$s in observations acquired with instruments (NICER and Aqueye+) whose absolute timing uncertainty is much smaller than the measured lag. We also show that the phase lag between optical and X-ray pulsations lies in a limited range of values, $δφ\in$ (0 $-$ 0.15), which is maintained over timescales of about five years. This indicates that both pulsations originate from the same region, and it supports the hypothesis of a common emission mechanism. Our results are interpreted in the shock-driven mini pulsar nebula scenario. This scenario suggests that optical and X-ray pulses are produced by synchrotron emission from the shock that formed within a few light cylinder radii away ($\sim$ 100 km) from the pulsar, where its striped wind encounters the accretion disk inflow.
△ Less
Submitted 23 November, 2022;
originally announced November 2022.
-
Design of SCALES: A 2-5 Micron Coronagraphic Integral Field Spectrograph for Keck Observatory
Authors:
Andrew Skemer,
R. Deno Stelter,
Stephanie Sallum,
Nicholas MacDonald,
Renate Kupke,
Christopher Ratliffe,
Ravinder Banyal,
Amirul Hasan,
Hari Mohan Varshney,
Arun Surya,
Ajin Prakash,
Sivarani Thirupathi,
Ramya Sethuraman,
Govinda K. V.,
Michael P. Fitzgerald,
Eric Wang,
Marc Kassis,
Olivier Absil,
Carlos Alvarez,
Natasha Batalha,
Marc-Andre Boucher,
Cyril Bourgenot,
Timothy Brandt,
Zackery Briesemeister,
Katherine de Kleer
, et al. (27 additional authors not shown)
Abstract:
We present the design of SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) a new 2-5 micron coronagraphic integral field spectrograph under construction for Keck Observatory. SCALES enables low-resolution (R~50) spectroscopy, as well as medium-resolution (R~4,000) spectroscopy with the goal of discovering and characterizing cold exoplanets that are brightest in the thermal…
▽ More
We present the design of SCALES (Slicer Combined with Array of Lenslets for Exoplanet Spectroscopy) a new 2-5 micron coronagraphic integral field spectrograph under construction for Keck Observatory. SCALES enables low-resolution (R~50) spectroscopy, as well as medium-resolution (R~4,000) spectroscopy with the goal of discovering and characterizing cold exoplanets that are brightest in the thermal infrared. Additionally, SCALES has a 12x12" field-of-view imager that will be used for general adaptive optics science at Keck. We present SCALES's specifications, its science case, its overall design, and simulations of its expected performance. Additionally, we present progress on procuring, fabricating and testing long lead-time components.
△ Less
Submitted 23 August, 2022;
originally announced August 2022.
-
Discovery of Localized Regions of Excess 10-TeV Cosmic Rays
Authors:
A. A. Abdo,
B. Allen,
T. Aune,
D. Berley,
E. Blaufuss,
S. Casanova,
C. Chen,
B. L. Dingus,
R. W. Ellsworth,
L. Fleysher,
R. Fleysher,
M. M. Gonzales,
J. A. Goodman,
C. M. Hoffman,
P. H. Hüntemeyer,
B. E. Kolterman,
C. P. Lansdell,
J. T. Linnemann,
J. E. McEnery,
A. I. Mincer,
P. Nemethy,
D. Noyes,
J. Pretz,
J. M. Ryan,
P. M. Saz Parkinson
, et al. (8 additional authors not shown)
Abstract:
An analysis of 7 years of Milagro data performed on a 10-degree angular scale has found two localized regions of excess of unknown origin with greater than 12 sigma significance. Both regions are inconsistent with gamma-ray emission with high confidence. One of the regions has a different energy spectrum than the isotropic cosmic-ray flux at a level of 4.6 sigma, and it is consistent with hard s…
▽ More
An analysis of 7 years of Milagro data performed on a 10-degree angular scale has found two localized regions of excess of unknown origin with greater than 12 sigma significance. Both regions are inconsistent with gamma-ray emission with high confidence. One of the regions has a different energy spectrum than the isotropic cosmic-ray flux at a level of 4.6 sigma, and it is consistent with hard spectrum protons with an exponential cutoff, with the most significant excess at ~10 TeV. Potential causes of these excesses are explored, but no compelling explanations are found.
△ Less
Submitted 14 October, 2008; v1 submitted 24 January, 2008;
originally announced January 2008.