Skip to main content

Showing 1–5 of 5 results for author: Gallucci, G

Searching in archive astro-ph. Search in all archives.
.
  1. arXiv:2502.10866  [pdf, other

    astro-ph.IM astro-ph.GA astro-ph.HE astro-ph.SR

    The X-ray Integral Field Unit at the end of the Athena reformulation phase

    Authors: Philippe Peille, Didier Barret, Edoardo Cucchetti, Vincent Albouys, Luigi Piro, Aurora Simionescu, Massimo Cappi, Elise Bellouard, Céline Cénac-Morthé, Christophe Daniel, Alice Pradines, Alexis Finoguenov, Richard Kelley, J. Miguel Mas-Hesse, Stéphane Paltani, Gregor Rauw, Agata Rozanska, Jiri Svoboda, Joern Wilms, Marc Audard, Enrico Bozzo, Elisa Costantini, Mauro Dadina, Thomas Dauser, Anne Decourchelle , et al. (257 additional authors not shown)

    Abstract: The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passi… ▽ More

    Submitted 15 February, 2025; originally announced February 2025.

    Comments: 44 pages, 14 figures, accepted for publication in Experimental Astronomy

  2. arXiv:2401.10827  [pdf

    astro-ph.IM physics.ins-det

    The TES-based Cryogenic AntiCoincidence Detector (CryoAC) of ATHENA X-IFU: a large area silicon microcalorimeter for background particles detection

    Authors: M. D'Andrea, C. Macculi, S. Lotti, L. Piro, A. Argan, G. Minervini, G. Torrioli, F. Chiarello, L. Ferrari Barusso, E. Celasco, G. Gallucci, F. Gatti, D. Grosso, M. Rigano, D. Brienza, E. Cavazzuti, A. Volpe

    Abstract: We are developing the Cryogenic AntiCoincidence detector (CryoAC) of the ATHENA X-IFU spectrometer. It is a TES-based particle detector aimed to reduce the background of the instrument. Here, we present the result obtained with the last CryoAC single-pixel prototype. It is based on a 1 cm2 silicon absorber sensed by a single 2mm x 1mm Ir/Au TES, featuring an on-chip heater for calibration and diag… ▽ More

    Submitted 19 January, 2024; originally announced January 2024.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-20 special issue

  3. arXiv:2206.15150  [pdf

    astro-ph.IM physics.ins-det

    ATHENA X-IFU Demonstration Model: First joint operation of the main TES Array and its Cryogenic AntiCoincidence Detector (CryoAC)

    Authors: M. D'Andrea, K. Ravensberg, A. Argan, D. Brienza, S. Lotti, C. Macculi, G. Minervini, L. Piro, G. Torrioli, F. Chiarello, L. Ferrari Barusso, M. Biasotti, G. Gallucci, F. Gatti, M. Rigano, H. Akamatsu, J. Dercksen, L. Gottardi, F. de Groote, R. den Hartog, J. -W. den Herder, R. Hoogeveen, B. Jackson, A. McCalden, S. Rosman , et al. (6 additional authors not shown)

    Abstract: The X-IFU is the cryogenic spectrometer onboard the future ATHENA X-ray observatory. It is based on a large array of TES microcalorimeters, which works in combination with a Cryogenic AntiCoincidence detector (CryoAC). This is necessary to reduce the particle background level thus enabling part of the mission science goals. Here we present the first joint test of X-IFU TES array and CryoAC Demonst… ▽ More

    Submitted 30 June, 2022; originally announced June 2022.

    Comments: Accepted for publication in the Journal of Low Temperature Physics for LTD-19 special issue

  4. arXiv:1807.02344  [pdf

    astro-ph.IM physics.ins-det

    The Cryogenic Anticoincidence Detector for ATHENA X-IFU: Preliminary test of AC-S9 towards the Demonstration Model

    Authors: Matteo D'Andrea, Claudio Macculi, Andrea Argan, Simone Lotti, Gabriele Minervini, Luigi Piro, Michele Biasotti, Valentina Ceriale, Giovanni Gallucci, Flavio Gatti, Guido Torrioli, Angela Volpe

    Abstract: Our team is developing the Cryogenic Anticoincidence Detector (CryoAC) of the ATHENA X-ray Integral Field Unit (X-IFU). It is a 4-pixels TES-based detector, which will be placed less than 1 mm below the main TES array detector. We are now producing the CryoAC Demonstration Model (DM): a single pixel prototype able to probe the detector critical technologies, i.e. the operation at 50 mK thermal bat… ▽ More

    Submitted 11 July, 2018; v1 submitted 6 July, 2018; originally announced July 2018.

    Comments: Proceeding of the SPIE Astronomical Telescopes + Instrumentation 2018

  5. arXiv:1210.0316  [pdf, ps, other

    physics.ins-det astro-ph.HE astro-ph.IM hep-ex

    The electromagnetic calorimeter of the AMS-02 experiment

    Authors: M. Vecchi, L. Basara, G. Bigongiari, F. Cervelli, G. Chen, G. M. Chen, H. S. Chen, G. Coignet, S. Di Falco, S. Elles, A. Fiasson, D. Fougeron, G. Gallucci, C. Goy, M. Incagli, R. Kossakowki, V. Lepareur, Z. H. Li, M. Maire, M. Paniccia, F. Pilo, S. Rosier-Lees, X. W. Tang, C. Vannini, J. P. Vialle , et al. (1 additional authors not shown)

    Abstract: The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a 3-dimensional sampling calorimeter, made of lead and scintillating fibers. The detector allows for a high granularity, with 18 samplings in the longitudinal direction, and 72 sampling in the lateral direction. The ECAL primary goal is to measure the energy of cosmic rays up to few TeV, however, thanks to the fine grained structur… ▽ More

    Submitted 1 October, 2012; originally announced October 2012.

    Comments: Proceedings of SF2A conference 2012