-
Recent and Upcoming Upgrades for MIRC-X and MYSTIC on the CHARA Array
Authors:
Noura Ibrahim,
Mayra Gutierrez,
John D. Monnier,
Stefan Kraus,
Jean-Baptiste Le Bouquin,
Narsireddy Anugu,
Theo ten Brummelaar,
Sorabh Chhabra,
Isabelle Codron,
Julien Dejonghe,
Aaron Labdon,
Daniel Lecron,
Daniel Mortimer,
Denis Mourard,
Gail Schaefer,
Benjamin Setterholm,
Manuela Arnó,
Andrea Bianco,
Michele Frangiamore,
Laurent Jocou
Abstract:
MIRC-X and MYSTIC are six-telescope near-infrared beam (1.08-2.38 $μ$m) combiners at the CHARA Array on Mt Wilson CA, USA. Ever since the commissioning of MIRC-X (J and H bands) in 2018 and MYSTIC (K bands) in 2021, they have been the most popular and over-subscribed instruments at the array. Observers have been able to image stellar objects with sensitivity down to 8.1 mag in H and 7.8 mag in K-b…
▽ More
MIRC-X and MYSTIC are six-telescope near-infrared beam (1.08-2.38 $μ$m) combiners at the CHARA Array on Mt Wilson CA, USA. Ever since the commissioning of MIRC-X (J and H bands) in 2018 and MYSTIC (K bands) in 2021, they have been the most popular and over-subscribed instruments at the array. Observers have been able to image stellar objects with sensitivity down to 8.1 mag in H and 7.8 mag in K-band under the very best conditions. In 2022 MYSTIC was upgraded with a new ABCD mode using the VLTI/GRAVITY 4-beam integrated optics chip, with the goal of improving the sensitivity and calibration. The ABCD mode has been used to observe more than 20 T Tauri stars; however, the data pipeline is still being developed. Alongside software upgrades, we detail planned upgrades to both instruments in this paper. The main upgrades are: 1) Adding a motorized filter wheel to MIRC-X along with new high spectral resolution modes 2) Updating MIRC-X optics to allow for simultaneous 6T J+H observations 3) Removing the warm window between the spectrograph and the warm optics in MYSTIC 4) Adding a 6T ABCD mode to MIRC-X in collaboration with CHARA/SPICA 5) Updating the MIRC-X CRED-ONE camera funded by Prof. Kraus from U. Exeter 6) Carrying out science verification of the MIRC-X polarization mode 7) Developing new software for ABCD-mode data reduction and more efficient calibration routines. We expect these upgrades to not only improve the observing experience, but also increase the sensitivity by 0.4 mag in J+H-bands, and 1 mag in K-band.
△ Less
Submitted 7 August, 2024;
originally announced August 2024.
-
A Precision Cryogenic Positioning Stage for Detector Dithering and Flexure Compensation
Authors:
Stephen A. Smee,
Stephen C. Hope,
Randolph P. Hammond,
Leon Aslan,
Robert H. Barkhouser,
Katherine G. Smee,
Andrea Bianco,
Christoph Birk,
Maren Cosens,
Aidan C. Gray,
Michele Frangiamore,
Albert C. Harding,
Tyson Hare,
Daniel D. Kelson,
Gerrad Killion,
Nicholas P. Konidaris II,
Alicia Lanz,
Jacob McCloskey,
Andrew B. Newman,
Solange Ramirez,
Gwen C. Rudie,
Andrea Vanella,
Jason E. Williams
Abstract:
This paper presents the design and technical progress of a precision X-Y stage for detector dithering and flexure compensation. The stage is being developed for use in the Magellan InfraRed Multi-Object Spectrograph, MIRMOS. MIRMOS is a very large Nasmyth mounted spectrograph containing a combination of refractive, reflective and diffractive optics mounted on a long cryogenic optical bench. The in…
▽ More
This paper presents the design and technical progress of a precision X-Y stage for detector dithering and flexure compensation. The stage is being developed for use in the Magellan InfraRed Multi-Object Spectrograph, MIRMOS. MIRMOS is a very large Nasmyth mounted spectrograph containing a combination of refractive, reflective and diffractive optics mounted on a long cryogenic optical bench. The instrument utilizes five science cameras, each having a custom x-y stage to control the in-plane detector position within each camera, providing both dithering capability for improved sampling, and flexure compensation to correct for image motion that results from the gravity variant operation of the instrument. Designed to operate at 120~K, the stage will accurately control detector position in two orthogonal degrees of freedom, and have manual fine adjustment features to set detector tip, tilt and piston. The piezo-driven flexure stage provides high-resolution backlash-free motion of the detector and is very compact along the optical path, keeping camera length to a minimum. A magnetoresistive bridge provides position feedback in each degree of freedom, greatly reducing hysteresis, which is common in piezoelectric actuators. The system is designed to operate in open loop using a lookup table keyed to the Nasmyth rotator angle for flexure control. Here, the optomechanical design of the stage, electrical control system, and current performance results from early prototype efforts are presented and discussed.
△ Less
Submitted 19 July, 2024;
originally announced July 2024.
-
A Novel Freeform Slicer IFU for the Magellan InfraRed Multi-Object Spectrograph (MIRMOS)
Authors:
Maren Cosens,
Nicholas P. Konidaris II,
Gwen C. Rudie,
Andrew B. Newman,
Gerrad Killion,
Leon Aslan,
Robert Barkhouser,
Andrea Bianco,
Christoph Birk,
Julia Brady,
Michele Frangiamore,
Tyson Hare,
Stephen C. Hope,
Daniel D. Kelson,
Alicia Lanz,
Solange Ramirez,
Stephen A. Smee,
Andrea Vanella,
Jason E. Williams
Abstract:
The Magellan InfraRed Multi-Object Spectrograph (MIRMOS) is a planned next generation multi-object and integral field spectrograph for the 6.5m Magellan telescopes at Las Campanas Observatory in Chile. MIRMOS will perform R$\sim$3700 spectroscopy over a simultaneous wavelength range of 0.886 - 2.404$μ$m (Y,J,H,K bands) in addition to imaging over the range of 0.7 - 0.886$μ$m. The integral field mo…
▽ More
The Magellan InfraRed Multi-Object Spectrograph (MIRMOS) is a planned next generation multi-object and integral field spectrograph for the 6.5m Magellan telescopes at Las Campanas Observatory in Chile. MIRMOS will perform R$\sim$3700 spectroscopy over a simultaneous wavelength range of 0.886 - 2.404$μ$m (Y,J,H,K bands) in addition to imaging over the range of 0.7 - 0.886$μ$m. The integral field mode of operation for MIRMOS will be achieved via an image slicer style integral field unit (IFU) located on a linear stage to facilitate movement into the beam during use or storage while operating in multi-object mode. The IFU will provide a $\rm \sim20"\times26"$ field of view (FoV) made up of $\rm0.84"\times26"$ slices. This will be the largest FoV IFS operating at these wavelengths from either the ground or space, making MIRMOS an ideal instrument for a wide range of science cases including studying the high redshift circumgalactic medium and emission line tracers from ionized and molecular gas in nearby galaxies. In order to achieve the desired image quality and FoV while matching the focal ratio to the multi-object mode, our slicer design makes use of novel freeform surfaces for the pupil mirrors, which require the use of high precision multi-axis diamond milling to manufacture. We present here the optical design and predicted performance of the MIRMOS IFU along with a conceptual design for the opto-mechanical system.
△ Less
Submitted 18 July, 2024;
originally announced July 2024.
-
The Blue Multi Unit Spectroscopic Explorer (BlueMUSE) on the VLT: characterization of two VPHG prototypes based on dichromated gelatin and photopolymer recording materials
Authors:
Alexandre Jeanneau,
Andrea Bianco,
Andrew Clawson,
Michele Frangiamore,
Elroy Pearson,
Laurent Pinard,
Jürgen Schmoll,
Johan Richard,
Rémi Giroud,
Florence Laurent,
Roland Bacon
Abstract:
Volume-phase holographic gratings (VPHGs) are widely used in astronomical spectrographs due to their adaptability and high diffraction efficiency. Most VPHGs in operation use dichromated gelatin as a recording material, whose performance is sensitive to the coating and development process, especially in the near-UV. In this letter, we present the characterization of two UV-blue VPHG prototypes for…
▽ More
Volume-phase holographic gratings (VPHGs) are widely used in astronomical spectrographs due to their adaptability and high diffraction efficiency. Most VPHGs in operation use dichromated gelatin as a recording material, whose performance is sensitive to the coating and development process, especially in the near-UV. In this letter, we present the characterization of two UV-blue VPHG prototypes for the BlueMUSE integral field spectrograph on the VLT, based on dichromated gelatin and the Bayfol$\circledR$HX photopolymer film as recording materials. Our measurements show that both prototypes meet the required diffraction efficiency and exhibit similar performance with a wavelength-average exceeding 70% in the 350-580 nm range. Deviations from theoretical models increase towards 350 nm, consistently with previous studies on similar gratings. We also report similar performances in terms spatial uniformity and grating-to-grating consistency. Likewise, no significant differences in wavefront error or scattered light are observed between the prototypes.
△ Less
Submitted 19 June, 2024;
originally announced June 2024.
-
Upgrading the high contrast imaging facility SPHERE: science drivers and instrument choices
Authors:
A. Boccaletti,
G. Chauvin,
F. Wildi,
J. Milli,
E. Stadler,
E. Diolaiti,
R. Gratton,
F. Vidal,
M. Loupias,
M. Langlois,
F. Cantalloube,
M. N'Diaye,
D. Gratadour,
F. Ferreira,
M. Tallon,
J. Mazoyer,
D. Segransan,
D. Mouillet,
J. -L. Beuzit,
M. Bonnefoy,
R. Galicher,
A. Vigan,
I. Snellen,
M. Feldt,
S. Desidera
, et al. (49 additional authors not shown)
Abstract:
SPHERE+ is a proposed upgrade of the SPHERE instrument at the VLT, which is intended to boost the current performances of detection and characterization for exoplanets and disks. SPHERE+ will also serve as a demonstrator for the future planet finder (PCS) of the European ELT. The main science drivers for SPHERE+ are 1/ to access the bulk of the young giant planet population down to the snow line (…
▽ More
SPHERE+ is a proposed upgrade of the SPHERE instrument at the VLT, which is intended to boost the current performances of detection and characterization for exoplanets and disks. SPHERE+ will also serve as a demonstrator for the future planet finder (PCS) of the European ELT. The main science drivers for SPHERE+ are 1/ to access the bulk of the young giant planet population down to the snow line ($3-10$ au), to bridge the gap with complementary techniques (radial velocity, astrometry); 2/ to observe fainter and redder targets in the youngest ($1-10$\,Myr) associations compared to those observed with SPHERE to directly study the formation of giant planets in their birth environment; 3/ to improve the level of characterization of exoplanetary atmospheres by increasing the spectral resolution in order to break degeneracies in giant planet atmosphere models. Achieving these objectives requires to increase the bandwidth of the xAO system (from $\sim$1 to 3\,kHz) as well as the sensitivity in the infrared (2 to 3\,mag). These features will be brought by a second stage AO system optimized in the infrared with a pyramid wavefront sensor. As a new science instrument, a medium resolution integral field spectrograph will provide a spectral resolution from 1000 to 5000 in the J and H bands. This paper gives an overview of the science drivers, requirements and key instrumental trade-off that were done for SPHERE+ to reach the final selected baseline concept.
△ Less
Submitted 5 September, 2022;
originally announced September 2022.
-
Spectrograph design for the Asgard/BIFROST spectro-interferometric instrument for the VLTI
Authors:
Sorabh Chhabra,
Michele Frangiamore,
Stefan Kraus,
Andrea Bianco,
Francisco Garzon,
John Monnier,
Daniel Mortimer
Abstract:
The BIFROST instrument will be the first VLTI instrument optimised for high spectral resolution up to R=25,000 and operate between 1.05 and 1.7 $μ$m. A key component of the instrument will be the spectrograph, where we require a high throughput over a broad bandwidth. In this contribution, we discuss the four planned spectral modes (R=50, R=1000, R=5000, and R=25,000), the key spectral windows tha…
▽ More
The BIFROST instrument will be the first VLTI instrument optimised for high spectral resolution up to R=25,000 and operate between 1.05 and 1.7 $μ$m. A key component of the instrument will be the spectrograph, where we require a high throughput over a broad bandwidth. In this contribution, we discuss the four planned spectral modes (R=50, R=1000, R=5000, and R=25,000), the key spectral windows that we need to cover, and the technology choices that we have considered. We present our plan to use Volume Phase Holographic Gratings (VPHGs) to achieve a high efficiency $>$ 85%. We present our preliminary optical design and our strategies for wavelength calibration.
△ Less
Submitted 10 August, 2022;
originally announced August 2022.