-
COSINUS model-independent sensitivity to the DAMA/LIBRA dark matter signal
Authors:
G. Angloher,
M. R. Bharadwaj,
A. Böhmer,
M. Cababie,
I. Colantoni,
I. Dafinei,
N. Di Marco,
C. Dittmar,
L. Einfalt,
F. Ferella,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
Z. Ge,
M. Heikinheimo,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro
, et al. (18 additional authors not shown)
Abstract:
COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scattering rate in sodium iodide. We investigate how this constraint can be used to infer that the annual modulation signal observed in DAMA/LIBRA experiment cannot originate from dark matter nuclear recoil events, independen…
▽ More
COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scattering rate in sodium iodide. We investigate how this constraint can be used to infer that the annual modulation signal observed in DAMA/LIBRA experiment cannot originate from dark matter nuclear recoil events, independent of the DM model. We achieve this by unfolding the DAMA modulation spectrum to obtain the implied unquenched nuclear recoil spectrum, which we compare to the expected COSINUS sensitivity. We find that assuming zero background in the signal region, a 1$σ$, 2$σ$ or 3$σ$ confidence limit exclusion can be obtained with 57, 130 or 250 kg day of exposure, respectively.
△ Less
Submitted 25 April, 2025;
originally announced April 2025.
-
Neutrino flux sensitivity to the next galactic core-collapse supernova in COSINUS
Authors:
G. Angloher,
M. R. Bharadwaj,
M. Cababie,
I. Colantoni,
I. Dafinei,
A. L. De Santis,
N. Di Marco,
L. Einfalt,
F. Ferella,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
Z. Ge,
M. Heikinheimo,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro,
F. Pröbst
, et al. (17 additional authors not shown)
Abstract:
While neutrinos are often treated as a background for many dark matter experiments, these particles offer a new avenue for physics: the detection of core-collapse supernovae. Supernovae are extremely energetic, violent and complex events that mark the death of massive stars. During their collapse stars emit a large number of neutrinos in a short burst. These neutrinos carry 99\% of the emitted ene…
▽ More
While neutrinos are often treated as a background for many dark matter experiments, these particles offer a new avenue for physics: the detection of core-collapse supernovae. Supernovae are extremely energetic, violent and complex events that mark the death of massive stars. During their collapse stars emit a large number of neutrinos in a short burst. These neutrinos carry 99\% of the emitted energy which makes their detection fundamental in understanding supernovae. This paper illustrates how COSINUS (Cryogenic Observatory for SIgnatures seen in Next-generation Underground Searches), a sodium iodide (NaI) based dark matter search, will be sensitive to the next galactic core-collapse supernova. The experiment is composed of two separate detectors which will be sensitive to far and nearby supernovae. The inner core of the experiment will consist of NaI crystals operating as scintillating calorimeters, mainly sensitive to the Coherent Elastic Scattering of Neutrinos (CE$ν$NS) against the Na and I nuclei. The low mass of the cryogenic detectors gives the experiment a sensitivity to close supernovae below 1kpc without pileup. They will see up to hundreds of CE$ν$NS events from a supernova happening at 200pc. The crystals reside at the center of a cylindrical 230T water tank, instrumented with 30 photomultipliers. This tank acts as a passive and active shield able to detect the Cherenkov radiation induced by impinging charged particles from ambient and cosmogenic radioactivity. A supernova near the Milky Way Center (10kpc) will be easily detected inducing $\sim$60 measurable events, and the water tank will have a 3$σ$ sensitivity to supernovae up to 22kpc, seeing $\sim$10 events. This paper shows how, even without dedicated optimization, modern dark matter experiments will also play their part in the multi-messenger effort to detect the next galactic core-collapse supernova.
△ Less
Submitted 6 February, 2025; v1 submitted 13 September, 2024;
originally announced September 2024.
-
High-Dimensional Bayesian Likelihood Normalisation for CRESST's Background Model
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
S. Fichtinger,
D. Fuchs,
A. Garai,
V. M. Ghete,
P. Gorla,
P. V. Guillaumon,
S. Gupta,
D. Hauff,
M. Jeskovsky,
J. Jochum,
M. Kaznacheeva
, et al. (37 additional authors not shown)
Abstract:
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, base…
▽ More
Using CaWO$_4$ crystals as cryogenic calorimeters, the CRESST experiment searches for nuclear recoils caused by the scattering of potential Dark Matter particles. A reliable identification of a potential signal crucially depends on an accurate background model. In this work we introduce an improved normalisation method for CRESST's model of the electromagnetic backgrounds. Spectral templates, based on Geant4 simulations, are normalised via a Bayesian likelihood fit to experimental background data. Contrary to our previous work, no assumption of partial secular equilibrium is required, which results in a more robust and versatile applicability. Furthermore, considering the correlation between all background components allows us to explain 82.7% of the experimental background within [1 keV, 40 keV], an improvement of 18.6% compared to our previous method.
△ Less
Submitted 9 January, 2025; v1 submitted 19 July, 2023;
originally announced July 2023.
-
Secular Equilibrium Assessment in a $\mathrm{CaWO}_4$ Target Crystal from the Dark Matter Experiment CRESST using Bayesian Likelihood Normalisation
Authors:
G. Angloher,
S. Banik,
G. Benato,
A. Bento,
A. Bertolini,
R. Breier,
C. Bucci,
J. Burkhart,
L. Canonica,
A. D'Addabbo,
S. Di Lorenzo,
L. Einfalt,
A. Erb,
F. v. Feilitzsch,
N. Ferreiro Iachellini,
S. Fichtinger,
D. Fuchs,
A. Fuss,
A. Garai,
V. M. Ghete,
P. Gorla,
S. Gupta,
D. Hauff,
M. Ješkovský,
J. Jochum
, et al. (36 additional authors not shown)
Abstract:
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-b…
▽ More
CRESST is a leading direct detection sub-$\mathrm{GeVc}^{-2}$ dark matter experiment. During its second phase, cryogenic bolometers were used to detect nuclear recoils off the $\mathrm{CaWO}_4$ target crystal nuclei. The previously established electromagnetic background model relies on secular equilibrium (SE) assumptions. In this work, a validation of SE is attempted by comparing two likelihood-based normalisation results using a recently developed spectral template normalisation method based on Bayesian likelihood. We find deviations from SE; further investigations are necessary to determine their origin.
△ Less
Submitted 24 January, 2023; v1 submitted 22 August, 2022;
originally announced September 2022.