-
GECAM Discovery of Peculiar Oscillating Particle Precipitation Events
Authors:
Chenwei Wang,
Shaolin Xiong,
Yi Zhao,
Wei Xu,
Gaopeng Lu,
Xuzhi Zhou,
Xiaocheng Guo,
Wenya Li,
Xiaochao Yang,
Qinghe Zhang,
Xinqiao Li,
Zhenxia Zhang,
Zhenghua An,
Ce Cai,
Peiyi Feng,
Yue Huang,
Min Gao,
Ke Gong,
Dongya Guo,
Haoxuan Guo,
Bing Li,
Xiaobo Li,
Yaqing Liu,
Jiacong Liu,
Xiaojing Liu
, et al. (30 additional authors not shown)
Abstract:
Charged particle precipitation typically manifests as a gradual increase and decrease of flux observed by space detectors. Cases with rapidly flux variation are very rare. Periodic events are even more extraordinary. These oscillating particle precipitation (OPP) events are usually attributed to the bounce motion of electrons, which are induced by lightning. Owing to the observation limitations, t…
▽ More
Charged particle precipitation typically manifests as a gradual increase and decrease of flux observed by space detectors. Cases with rapidly flux variation are very rare. Periodic events are even more extraordinary. These oscillating particle precipitation (OPP) events are usually attributed to the bounce motion of electrons, which are induced by lightning. Owing to the observation limitations, there has been debate regarding whether these oscillations originate from temporal flux evolution or spatial structure evolution. Here we report three peculiar charged particle precipitation events detected by GECAM during a geomagnetic storm on March 21, 2024, with two exhibiting significant periodicity. These events were observed around the same region during three consecutive orbits. Through comprehensive temporal and spectral analyses, we revealed that one of the OPP events exhibited a transition in spectral lag of mini-pulses, shifting from "softer-earlier" to "softer-later" while showing no significant time evolution in overall frequency characteristics. And there is no association found between these two OPP events and lightning activity. Several possible scenarios are discussed to explain these charged particles with a life time of more than 3.5 hours, but the nature of these three events remains an enigma. We suggest that these GECAM-detected OPP events may represent a new type of particle precipitation event or a peculiar Lightning-induced Electron Precipitations (LEPs).
△ Less
Submitted 9 May, 2025;
originally announced May 2025.
-
Pitch Angle Measurement Method based on Detector Counts Distribution. -I. Basic conception
Authors:
Chenwei Wang,
Shaolin Xiong,
Hongbo Xue,
Yiteng Zhang,
Shanzhi Ye,
Wei Xu,
Jinpeng Zhang,
Zhenghua An,
Ce Cai,
Peiyi Feng,
Ke Gong,
Haoxuan Guo,
Yue Huang,
Xinqiao Li,
Jiacong Liu,
Xiaojing Liu,
Xiang Ma,
Liming Song,
Wenjun Tan,
Jin Wang,
Ping Wang,
Yue Wang,
Xiangyang Wen,
Shuo Xiao,
Shenlun Xie
, et al. (14 additional authors not shown)
Abstract:
As an X-ray and gamma-ray all-sky monitor aiming for high energy astrophysical transients, Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) has also made a series of observational discoveries on burst events of gamma-rays and particles in the low Earth orbit. Pitch angle is one of the key parameters of charged particles traveling around geomagnetic field. However,…
▽ More
As an X-ray and gamma-ray all-sky monitor aiming for high energy astrophysical transients, Gravitational-wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) has also made a series of observational discoveries on burst events of gamma-rays and particles in the low Earth orbit. Pitch angle is one of the key parameters of charged particles traveling around geomagnetic field. However, the usage of the GECAM-style instruments to measure the pitch angle of charged particles is still lacking. Here we propose a novel method for GECAM and similar instruments to measure the pitch angle of charged particles based on detector counts distribution. The basic conception of this method and simulation studies are described. With this method, the pitch angle of a peculiar electron precipitation event detected by GECAM-C is derived to be about 90$^\circ$, demonstrating the feasibility of our method. We note that the application of this method on GECAM-style instruments may open a new window for studying space particle events, such as Terrestrial Electron Beams (TEBs) and Lightning-induced Electron Precipitations (LEPs).
△ Less
Submitted 9 May, 2025;
originally announced May 2025.
-
Identifying New $γ$-Ray Sources in All-Sky Surveys Based on Fermipy's Advanced Algorithm
Authors:
Y. C. Xiang,
P. Feng,
X. F. Lan
Abstract:
We employ an efficient method for identifying gamma-ray sources across the entire sky, leveraging advanced algorithms from Fermi p y, and cleverly utilizing the Galactic diffuse background emission model to partition the entire sky into 72 regions,thereby greatly enhancing the efficiency of discovering new sources throughout the sky through multi-threaded parallel computing. After confirming the r…
▽ More
We employ an efficient method for identifying gamma-ray sources across the entire sky, leveraging advanced algorithms from Fermi p y, and cleverly utilizing the Galactic diffuse background emission model to partition the entire sky into 72 regions,thereby greatly enhancing the efficiency of discovering new sources throughout the sky through multi-threaded parallel computing. After confirming the reliability of the new method, we applied it for the first time to analyze data from the Fermi Large Area Telescope encompassing approximately 15.41yr of all sky surveys.
Through this analysis, we successfully identified 1379 new sources with levels exceeding 4sigma, of which 497 sources exhibited higher significance levels exceeding 5sigma. Subsequently, we performed a systematic analysis of the spatial extension, spectra, and light variation characteristics of these newly identified sources. We identified 21 extended sources and 23 sources exhibiting spectral curvature above 10GeV. Additionally, we identified 44 variable sources above 1GeV.
△ Less
Submitted 24 December, 2024;
originally announced December 2024.
-
Ground electron calibration of the Gamma-ray Transient Monitor onboard DRO-A Satellite
Authors:
Pei-Yi Feng,
Zheng-Hua An,
Yu-Hui Li,
Qi Le,
Da-Li Zhang,
Xin-Qiao Li,
Shao-Lin Xiong,
Cong-Zhan Liu,
Wei-Bin Liu,
Jian-Li Wang,
Bing-Lin Deng,
He Xu,
Hong Lu
Abstract:
The Gamma-Ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite, with the scientific objective of detecting gamma-ray bursts in the energy range of 20 keV to 1 MeV. The GTM is equipped with five Gamma-Ray Transient Probes (GTPs), utilizing silicon photomultiplier (SiPM) arrays coupled with NaI(Tl) scintillators for signal readout. To test the pe…
▽ More
The Gamma-Ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite, with the scientific objective of detecting gamma-ray bursts in the energy range of 20 keV to 1 MeV. The GTM is equipped with five Gamma-Ray Transient Probes (GTPs), utilizing silicon photomultiplier (SiPM) arrays coupled with NaI(Tl) scintillators for signal readout. To test the performance of the GTP in detecting electrons, we independently developed a continuous-energy-tunable, low-current, quasi-single-electron accelerator, and used this facility for ground-based electron calibration of the GTP. This paper provides a detailed description of the operational principles of the unique electron accelerator and comprehensively presents the process and results of electron calibration for the GTP. The calibration results indicate that the dead time for normal signals is less than 4 $μ$s, while for overflow signals, it is approximately 70 $μ$s, consistent with the design specifications. The GTP's time-recording capability is working correctly, accurately recording overflow events. The GTP responds normally to electrons in the 0.4-1.4 MeV energy range. The ground-based electron calibration validates the design of the GTP and enhances the probe's mass model, laying the foundation for payload development, in-orbit observation strategies, and scientific data analysis.
△ Less
Submitted 28 November, 2024;
originally announced November 2024.
-
Detector performance of the Gamma-ray Transient Monitor onboard DRO-A Satellite
Authors:
Pei-Yi Feng,
Zheng-Hua An,
Da-Li Zhang,
Chen-Wei Wang,
Chao Zheng,
Sheng Yang,
Shao-Lin Xiong,
Jia-Cong Liu,
Xin-Qiao Li,
Ke Gong,
Xiao-Jing Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing liu,
Xiao-Yun Zhao,
Fan Zhang,
Xi-Lei Sun,
Hong Lu
Abstract:
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dua…
▽ More
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dual-channel coincident readout design. In this work, we firstly studied the impact of different coincidence times on detection efficiency and ultimately selected the 500 ns time coincidence window for offline data processing. To test the performance of GTPs and validate the Monte Carlo simulated energy response, we conducted comprehensive ground calibration tests using Hard X-ray Calibration Facility (HXCF) and radioactive sources, including energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively presented the ground calibration results, and validated the design and mass model of GTP detector. These work paved the road for the in-flight observation and science data analysis.
△ Less
Submitted 10 September, 2024; v1 submitted 15 January, 2024;
originally announced January 2024.
-
The Intrinsic Energy Resolution of LaBr$_3$(Ce) Crystal for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Zheng-Hua An,
Cheng-Er Wang,
Da-Li Zhang,
Xin-Qiao Li,
Chao Zheng,
Shao-Lin Xiong,
Hong Lu
Abstract:
This study aims to provide an accurate estimation of the intrinsic resolution of LaBr$_3$(Ce) crystal through a combination of experimental and simulation methods. We re-analyzed the data from previous Wide-Angle Compton Coincidence (WACC) and Hard X-ray Calibration Facility (HXCF) experiments, conducted PMT Single-Photoelectron Calibration (SPEC) and radial non-uniformity (also called Spot Scanni…
▽ More
This study aims to provide an accurate estimation of the intrinsic resolution of LaBr$_3$(Ce) crystal through a combination of experimental and simulation methods. We re-analyzed the data from previous Wide-Angle Compton Coincidence (WACC) and Hard X-ray Calibration Facility (HXCF) experiments, conducted PMT Single-Photoelectron Calibration (SPEC) and radial non-uniformity (also called Spot Scanning, SS) experiments to acquire new data, and combined these results with Geant4 simulations to isolate the contribution of each physical process to the total energy resolution, thereby allowing for a precise estimation of the scintillator's intrinsic resolution. For 100 keV X-rays, the total energy resolution of LaBr$_3$(Ce) crystal is 3.99% $\pm$ 0.04% (expressed as 1-$σ$), with statistical fluctuations and intrinsic resolution as the main components, contributing 2.47% $\pm$ 0.00% and 3.06% $\pm$ 0.06%, respectively. We identify two main sources of intrinsic resolution: one primarily due to non-proportional scintillation, contributing 2.28% $\pm$ 0.00%, and the other due to fluctuations in the energy transfer process, contributing 2.04% $\pm$ 0.08%. We quantified six components of the total energy resolution and reconstructed the photon response using Geant4. The consistency between the reconstructed relative light yield and the experimental measurements validated the mass model of the LaBr$_3$(Ce) detector used in the simulations.
△ Less
Submitted 3 January, 2025; v1 submitted 30 December, 2023;
originally announced January 2024.
-
The Energy Response of LaBr3(Ce), LaBr3(Ce,Sr) and NaI(Tl) Crystals for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Zheng-Hua An,
Yong Deng,
Cheng-Er Wang,
Huang Jiang,
Jun-Jie Li,
Da-Li Zhang,
Xin-Qiao Li,
Shao-Lin Xiong,
Chao Zheng,
Ke Gong,
Sheng Yang,
Xiao-Jing Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing Liu,
Yan-Bing Xu,
Xiao-Yun Zhao,
Jia-Cong Liu,
Fan Zhang,
Hong Lu
Abstract:
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons,…
▽ More
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons, radioactive sources, and mono-energetic X-rays. The non-linearity test results for Compton electrons and X-rays displayed substantial differences, with all three crystals showing higher non-linearity for X-rays and gamma-rays than for Compton electrons. Despite LaBr3(Ce) and LaBr3(Ce,Sr) crystals having higher absolute light yields, they exhibited a noticeable non-linear decrease in light yield, especially at energies below 400 keV. The NaI(Tl) crystal demonstrated excess light output in the 6~200 keV range, reaching a maximum excess of 9.2% at 30 keV in X-ray testing and up to 15.5% at 14 keV during Compton electron testing, indicating a significant advantage in the detection of low-energy gamma rays. Furthermore, this paper explores the underlying causes of the observed non-linearity in these crystals. This study not only elucidates the detector responses of GECAM, but also marks the inaugural comprehensive investigation into the non-linearity of domestically produced lanthanum bromide and sodium iodide crystals.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Evidence of mini-jet emission in a large emission zone from a magnetically-dominated gamma-ray burst jet
Authors:
S. -X. Yi,
C. -W. Wang,
X. -Y. Shao,
R. Moradi,
H. Gao,
B. Zhang,
S. -L. Xiong,
S. -N. Zhang,
W. -J. Tan,
J. -C. Liu,
W. -C. Xue,
Y. -Q. Zhang,
C. Zheng,
Y. Wang,
P. Zhang,
Z. -H. An,
C. Cai,
P. -Y. Feng,
K. Gong,
D. -Y. Guo,
Y. Huang,
B. Li,
X. -B. Li,
X. -Q. Li,
X. -J. Liu
, et al. (21 additional authors not shown)
Abstract:
The second brightest GRB in history, GRB230307A, provides an ideal laboratory to study the mechanism of GRB prompt emission thanks to its extraordinarily high photon statistics and its single episode activity. Here we demonstrate that the rapidly variable components of its prompt emission compose an overall broad single pulse-like profile. Although these individual rapid components are aligned in…
▽ More
The second brightest GRB in history, GRB230307A, provides an ideal laboratory to study the mechanism of GRB prompt emission thanks to its extraordinarily high photon statistics and its single episode activity. Here we demonstrate that the rapidly variable components of its prompt emission compose an overall broad single pulse-like profile. Although these individual rapid components are aligned in time across all energy bands, this overall profile conspires to show a well-defined energy-dependent behavior which is typically seen in single GRB pulses. Such a feature demonstrates that the prompt emission of this burst is from many individual emitting units that are casually linked in a emission site at a large distance from the central engine. Such a scenario is in natural consistency with the internal-collision-induced magnetic reconnection and turbulence framework, which invokes many mini-jets due to local magnetic reconnection that constantly appear and disappear in a global magnetically-dominated jet.
△ Less
Submitted 21 April, 2025; v1 submitted 11 October, 2023;
originally announced October 2023.
-
GECAM Observations of the Galactic Magnetar SGR J1935+2154 during the 2021 and 2022 Burst Active Episodes. I. Burst Catalog
Authors:
Sheng-Lun Xie,
Ce Cai,
Yun-Wei Yu,
Shao-Lin Xiong,
Lin Lin,
Yi Zhao,
Shuang-Nan Zhang,
Li-Ming Song,
Ping Wang,
Xiao-Bo Li,
Wang-Chen Xue,
Peng Zhang,
Chao Zheng,
Yan-Qiu Zhang,
Jia-Cong Liu,
Chen-Wei Wang,
Wen-Jun Tan,
Yue Wang,
Zheng-Hang Yu,
Pei-Yi Feng,
Jin-Peng Zhang,
Shuo Xiao,
Hai-Sheng Zhao,
Wen-Long Zhang,
Yan-Ting Zhang
, et al. (12 additional authors not shown)
Abstract:
Magnetar is a neutron star with an ultrahigh magnetic field ($\sim 10^{14}-10^{15}$ G). The magnetar SGR J1935+2154 is not only one of the most active magnetars detected so far, but also the unique confirmed source of fast radio bursts (FRBs). Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to monitor gamma-ray transients all over the sky, including…
▽ More
Magnetar is a neutron star with an ultrahigh magnetic field ($\sim 10^{14}-10^{15}$ G). The magnetar SGR J1935+2154 is not only one of the most active magnetars detected so far, but also the unique confirmed source of fast radio bursts (FRBs). Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) is dedicated to monitor gamma-ray transients all over the sky, including magnetar short bursts. Here we report the GECAM observations of the burst activity of SGR J1935+2154 from January 2021 to December 2022, which results in a unique and valuable data set for this important magnetar. With a targeted search of GECAM data, 159 bursts from SGR J1935+2154 are detected by GECAM-B while 97 bursts by GECAM-C, including the X-ray burst associated with a bright radio burst. We find that both the burst duration and the waiting time between two successive bursts follow lognormal distributions. The period of burst activity is $134\pm20$ days, thus the burst activity could be generally divided into four active episodes over these two years. Interestingly, the hardness ratio of X-ray bursts tends to be softer during these two years, especially during the active episode with radio bursts detected.
△ Less
Submitted 12 February, 2025; v1 submitted 3 July, 2023;
originally announced July 2023.
-
Cross calibration of gamma-ray detectors (GRD) of GECAM-C
Authors:
Yan-Qiu Zhang,
Shao-Lin Xiong,
Rui Qiao,
Dong-Ya Guo,
Wen-Xi Peng,
Xin-Qiao Li,
Wang-Chen Xue,
Chao Zheng,
Jia-Cong Liu,
Wen-Jun Tan,
Chen-Wei Wang,
Peng Zhang,
Ping Wang,
Ce Cai,
Shuo Xiao,
Yue Huang,
Pei-Yi Feng,
Xiao-Bo Li,
Li-Ming Song,
Qi-Bin Yi,
Yi Zhao,
Zhi-Wei Guo,
Jian-Jian He,
Chao-Yang Li,
Ya-Qing Liu
, et al. (20 additional authors not shown)
Abstract:
The gamma-ray detectors (GRDs) of GECAM-C onborad SATech-01 satellite is designed to monitor gamma-ray transients all over the sky from 6 keV to 6 MeV. The energy response matrix is the key to do spectral measurements of bursts, which is usually generated from GEANT4 simulation and partially verified by the ground calibration. In this work, energy response matrix of GECAM-C GRD is cross-calibrated…
▽ More
The gamma-ray detectors (GRDs) of GECAM-C onborad SATech-01 satellite is designed to monitor gamma-ray transients all over the sky from 6 keV to 6 MeV. The energy response matrix is the key to do spectral measurements of bursts, which is usually generated from GEANT4 simulation and partially verified by the ground calibration. In this work, energy response matrix of GECAM-C GRD is cross-calibrated with Fermi/GBM and Swift/BAT using a sample of Gamma-Ray Bursts (GRBs) and Soft Gamma-Ray Repeaters (SGRs). The calibration results show there is a good agreement between GECAM-C and other reasonably well calibrated instrument (i.e. Fermi/GBM and Swift/BAT). We also find that different GRD detectors of GECAM-C also show consistency with each other. All these results indicate that GECAM-C GRD can provide reliable spectral measurements.
△ Less
Submitted 1 March, 2023;
originally announced March 2023.
-
Ground calibration of Gamma-Ray Detectors of GECAM-C
Authors:
Chao Zheng,
Zheng-Hua An,
Wen-Xi Peng,
Da-Li Zhang,
Shao-Lin Xiong,
Rui. Qiao,
Yan-Qiu Zhang,
Wang-Chen Xue,
Jia-Cong Liu,
Pei-Yi Feng,
Ce. Cai,
Min Gao,
Ke Gong,
Dong-Ya Guo,
Dong-Jie Hou,
Gang Li,
Xin-Qiao Li,
Yan-Guo Li,
Mao-Shun Li,
Xiao-Hua Liang,
Ya-Qing Liu,
Xiao-Jing Liu,
Li-Ming Song,
Xi-Lei Sun,
Wen-Jun Tan
, et al. (13 additional authors not shown)
Abstract:
As a new member of GECAM mission, GECAM-C (also named High Energy Burst Searcher, HEBS) was launched onboard the SATech-01 satellite on July 27th, 2022, which is capable to monitor gamma-ray transients from $\sim$ 6 keV to 6 MeV. As the main detector, there are 12 gamma-ray detectors (GRDs) equipped for GECAM-C. In order to verify the GECAM-C GRD detector performance and to validate the Monte Carl…
▽ More
As a new member of GECAM mission, GECAM-C (also named High Energy Burst Searcher, HEBS) was launched onboard the SATech-01 satellite on July 27th, 2022, which is capable to monitor gamma-ray transients from $\sim$ 6 keV to 6 MeV. As the main detector, there are 12 gamma-ray detectors (GRDs) equipped for GECAM-C. In order to verify the GECAM-C GRD detector performance and to validate the Monte Carlo simulations of detector response, comprehensive on-ground calibration experiments have been performed using X-ray beam and radioactive sources, including Energy-Channel relation, energy resolution, detection efficiency, SiPM voltage-gain relation and the non-uniformity of positional response. In this paper, the detailed calibration campaigns and data analysis results for GECAM-C GRDs are presented, demonstrating the excellent performance of GECAM-C GRD detectors.
△ Less
Submitted 30 May, 2023; v1 submitted 1 March, 2023;
originally announced March 2023.
-
The performance of SiPM-based gamma-ray detector (GRD) of GECAM-C
Authors:
Dali Zhang,
Chao Zheng,
Jiacong Liu,
Zhenghua An,
Chenwei Wang,
Xiangyang Wen,
Xinqiao Li,
Xilei Sun,
Ke Gong,
Yaqing Liu,
Xiaojing Liu,
Sheng Yang,
Wenxi Peng,
Rui Qiao,
Dongya Guo,
Peiyi Feng,
Yanqiu Zhang,
Wangchen Xue,
Wenjun Tan,
Ce Cai,
Shuo Xiao,
Qibin Yi,
Yanbing Xu,
Min Gao,
Jinzhou Wang
, et al. (20 additional authors not shown)
Abstract:
As a new member of GECAM mission, the GECAM-C (also called High Energy Burst Searcher, HEBS) is a gamma-ray all-sky monitor onboard SATech-01 satellite, which was launched on July 27th, 2022 to detect gamma-ray transients from 6 keV to 6 MeV, such as Gamma-Ray Bursts (GRBs), high energy counterpart of Gravitational Waves (GWs) and Fast Radio Bursts (FRBs), and Soft Gamma-ray Repeaters (SGRs). Toge…
▽ More
As a new member of GECAM mission, the GECAM-C (also called High Energy Burst Searcher, HEBS) is a gamma-ray all-sky monitor onboard SATech-01 satellite, which was launched on July 27th, 2022 to detect gamma-ray transients from 6 keV to 6 MeV, such as Gamma-Ray Bursts (GRBs), high energy counterpart of Gravitational Waves (GWs) and Fast Radio Bursts (FRBs), and Soft Gamma-ray Repeaters (SGRs). Together with GECAM-A and GECAM-B launched in December 2020, GECAM-C will greatly improve the monitoring coverage, localization, as well as temporal and spectral measurements of gamma-ray transients. GECAM-C employs 12 SiPM-based Gamma-Ray Detectors (GRDs) to detect gamma-ray transients . In this paper, we firstly give a brief description of the design of GECAM-C GRDs, and then focus on the on-ground tests and in-flight performance of GRDs. We also did the comparison study of the SiPM in-flight performance between GECAM-C and GECAM-B. The results show GECAM-C GRD works as expected and is ready to make scientific observations.
△ Less
Submitted 7 March, 2023; v1 submitted 1 March, 2023;
originally announced March 2023.
-
The design and performance of GRD onboard the GECAM satellite
Authors:
Z. H. An,
X. L. Sun,
D. L. Zhang,
S. Yang,
X. Q. Li,
X. Y. Wen,
K. Gong,
X. H. Liang,
X. J. Liu,
Y. Q. Liu,
Y. G. Li,
S. L. Xiong,
Y. B. Xu,
Fan Zhang,
X. Y. Zhao,
C. Cai,
Z. Chang,
G. Chen,
C. Chen,
Y. Y. Du,
P. Y. Feng,
M. Gao,
R. Gao,
D. Y. Guo,
J. J. He
, et al. (26 additional authors not shown)
Abstract:
Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are…
▽ More
Background: Each GECAM satellite payload contains 25 gamma-ray detectors (GRDs), which can detect gamma-rays and particles and can roughly localize the Gamma-Ray Bursts (GRBs). GRD was designed using lanthanum bromide (LaBr3) crystal as the sensitive material with the rear end coupled with silicon photomultiplier (SiPM) array for readout. Purpose: In aerospace engineering design of GRD, there are many key points to be studied. In this paper, we present the specific design scheme of GRD, the assembly and the performance test results of detectors. Methods: Based on Monte Carlo simulation and experimental test results, the specific schematic design and assembling process ofGRDwere optimized. After being fully assembled, theGRDswere conducted performance tests by using radioactive source and also conducted random vibration tests. Result and conclusion: The test results show that all satellite-borne GRDs have energy resolution <16% at 59.5 keV, meeting requirements of satellite in scientific performance. The random vibration test shows that GRD can maintain in a stable performance, which meets the requirement of spatial application.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.