The MICADO first light imager for the ELT: Testing the Lyot coronograph prototypes
Authors:
Pierre Baudoz,
Elsa Huby,
Olivier Dupuis,
Faouzi Boussaha,
Yann Clénet,
Ric Davies
Abstract:
MICADO, the European Extremely Large Telescope first light imager will feature a dedicated high contrast imaging mode specifically designed for observing and characterizing exoplanets and circumstellar disks. Its improved sensitivity and angular resolution, compared to existing instruments will significantly increase our knowledge on these planetary systems. MICADO will include three classical Lyo…
▽ More
MICADO, the European Extremely Large Telescope first light imager will feature a dedicated high contrast imaging mode specifically designed for observing and characterizing exoplanets and circumstellar disks. Its improved sensitivity and angular resolution, compared to existing instruments will significantly increase our knowledge on these planetary systems. MICADO will include three classical Lyot coronagraphs, one vector phase-apodized pupil plane (vAPP) and two sparse apertures. After rapidly describing the final design of MICADO high contrast mode, we will describe the current state of development of the coronographic components and the testing of the first Lyot coronagraph prototypes.
△ Less
Submitted 20 November, 2024;
originally announced November 2024.
-
The MICADO first light imager for the ELT: overview and current Status
Authors:
E. Sturm,
R. Davies,
J. Alves,
Y. Clénet,
J. Kotilainen,
A. Monna,
H. Nicklas,
J. -U. Pott,
E. Tolstoy,
B. Vulcani,
J. Achren,
S. Annadevara,
H. Anwand-Heerwart,
C. Arcidiacono,
S. Barboza,
L. Barl,
P. Baudoz,
R. Bender,
N. Bezawada,
F. Biondi,
P. Bizenberger,
A. Blin,
A. Boné,
P. Bonifacio,
B. Borgo
, et al. (129 additional authors not shown)
Abstract:
MICADO is a first light instrument for the Extremely Large Telescope (ELT), set to start operating later this decade. It will provide diffraction limited imaging, astrometry, high contrast imaging, and long slit spectroscopy at near-infrared wavelengths. During the initial phase operations, adaptive optics (AO) correction will be provided by its own natural guide star wavefront sensor. In its fina…
▽ More
MICADO is a first light instrument for the Extremely Large Telescope (ELT), set to start operating later this decade. It will provide diffraction limited imaging, astrometry, high contrast imaging, and long slit spectroscopy at near-infrared wavelengths. During the initial phase operations, adaptive optics (AO) correction will be provided by its own natural guide star wavefront sensor. In its final configuration, that AO system will be retained and complemented by the laser guide star multi-conjugate adaptive optics module MORFEO (formerly known as MAORY). Among many other things, MICADO will study exoplanets, distant galaxies and stars, and investigate black holes, such as Sagittarius A* at the centre of the Milky Way. After their final design phase, most components of MICADO have moved on to the manufacturing and assembly phase. Here we summarize the final design of the instrument and provide an overview about its current manufacturing status and the timeline. Some lessons learned from the final design review process will be presented in order to help future instrumentation projects to cope with the challenges arising from the substantial differences between projects for 8-10m class telescopes (e.g. ESO-VLT) and the next generation Extremely Large Telescopes (e.g. ESO-ELT). Finally, the expected performance will be discussed in the context of the current landscape of astronomical observatories and instruments. For instance, MICADO will have similar sensitivity as the James Webb Space Telescope (JWST), but with six times the spatial resolution.
△ Less
Submitted 29 August, 2024;
originally announced August 2024.
-
A Family of Phase Masks For Broadband Coronagraphy Example of the Wrapped Vortex Phase Mask Theory and Laboratory demonstration
Authors:
Raphaël Galicher,
Pierre Baudoz,
Elsa Huby,
Olivier Dupuis
Abstract:
Future instruments need efficient coronagraphs over large spectral ranges to enable broadband imaging or spectral characterization of exoplanets 1e8 fainter than their star. Several solutions were proposed. Pupil apodizers can attenuate the star intensity by a 1e10 factor but they transmit a few percents of the planet light only. Cascades of phase/amplitude masks can both attenuate the starlight a…
▽ More
Future instruments need efficient coronagraphs over large spectral ranges to enable broadband imaging or spectral characterization of exoplanets 1e8 fainter than their star. Several solutions were proposed. Pupil apodizers can attenuate the star intensity by a 1e10 factor but they transmit a few percents of the planet light only. Cascades of phase/amplitude masks can both attenuate the starlight and transmit most of the planet light but the number of optics to align is not a practical solution for an instrument. Finally, vector phase masks can be used to detect faint sources close to bright stars but they require the use of high quality circular polarizers and as for the previous solution, this leads to a complex instrument with numerous optics to align and stabilize. We propose simple coronagraphs that need one scalar phase mask and one binary Lyot stop only providing high transmission for the planet light (>50%) and high attenuation of the starlight over a large spectral bandpass (~30%) and a 360 degree field-of-view. From mathematical considerations, we find a family of 2D-phase masks optimized for an unobscured pupil. One mask is an azimuthal wrapped vortex phase ramp. We probe its coronagraphic performance using numerical simulations and laboratory tests. From numerical simulations, we predict the wrapped vortex can attenuate the peak of the star image by a factor of 1e4 over a 29% bandpass and 1e5 over a 18% bandpass with transmission of more than 50% of the planet flux at ~4 lambda/D. We confirm these predictions in laboratory in visible light between 550nm and 870nm. We also obtain laboratory dark hole images in which exoplanets with fluxes that are 3e-8 times the host star flux could be detected at 3sigma. Taking advantage of a new technology for etching continuous 2D-functions, new type of masks can be easily manufactured opening new possibilities for broadband coronagraphy.
△ Less
Submitted 16 January, 2020;
originally announced January 2020.
-
Active minimization of non-common path aberrations in long-exposure imaging of exoplanetary systems
Authors:
Garima Singh,
Raphaël Galicher,
Pierre Baudoz,
Olivier Dupuis,
Manuel Ortiz,
Axel Potier,
Simone Thijs,
Elsa Huby
Abstract:
Context. Spectroscopy of exoplanets is very challenging because of the high star-planet contrast. A technical difficulty in the design of imaging instruments is the noncommon path aberrations (NCPAs) between the adaptive optics (AO) sensing and the science camera, which induce planet-resembling stellar speckles in the coronagraphic science images. In an observing sequence of several long exposures…
▽ More
Context. Spectroscopy of exoplanets is very challenging because of the high star-planet contrast. A technical difficulty in the design of imaging instruments is the noncommon path aberrations (NCPAs) between the adaptive optics (AO) sensing and the science camera, which induce planet-resembling stellar speckles in the coronagraphic science images. In an observing sequence of several long exposures, quickly evolving NCPAs average out and leave behind an AO halo that adds photon noise to the planet detection. Static NCPA can be calibrated a posteriori using differential imaging techniques. However, NCPAs that evolve during the observing sequence do not average out and cannot be calibrated a posteriori. These quasi-static NCPAs are one of the main limitations of the current direct imaging instruments such as SPHERE, GPI, and SCExAO.
Aims. Our aim is to actively minimize the quasi-static speckles induced in long-exposure images. To do so, we need to measure the quasi-static speckle field above the AO halo.
Methods. The self-coherent camera (SCC) is a proven technique which measures the speckle complex field in the coronagraphic science images. It is routinely used on the THD2 bench to reach contrast levels of <10^{-8} in the range 5-12 λ/D in space-related conditions. To test the SCC in ground conditions on THD2, we optically simulated the residual aberrations measured behind the SPHERE/VLT AO system under good observing conditions.
Results. We demonstrate in the laboratory that the SCC can minimize the quasi-static speckle intensity in the science images down to a limitation set by the AO halo residuals. The SCC reaches 1σ raw contrast levels below 10^{-6} in the region 5-12 λ/D at 783.25 nm in our experiments.
△ Less
Submitted 1 October, 2019;
originally announced October 2019.
-
SPHERE: the exoplanet imager for the Very Large Telescope
Authors:
J. -L. Beuzit,
A. Vigan,
D. Mouillet,
K. Dohlen,
R. Gratton,
A. Boccaletti,
J. -F. Sauvage,
H. M. Schmid,
M. Langlois,
C. Petit,
A. Baruffolo,
M. Feldt,
J. Milli,
Z. Wahhaj,
L. Abe,
U. Anselmi,
J. Antichi,
R. Barette,
J. Baudrand,
P. Baudoz,
A. Bazzon,
P. Bernardi,
P. Blanchard,
R. Brast,
P. Bruno
, et al. (86 additional authors not shown)
Abstract:
Observations of circumstellar environments to look for the direct signal of exoplanets and the scattered light from disks has significant instrumental implications. In the past 15 years, major developments in adaptive optics, coronagraphy, optical manufacturing, wavefront sensing and data processing, together with a consistent global system analysis have enabled a new generation of high-contrast i…
▽ More
Observations of circumstellar environments to look for the direct signal of exoplanets and the scattered light from disks has significant instrumental implications. In the past 15 years, major developments in adaptive optics, coronagraphy, optical manufacturing, wavefront sensing and data processing, together with a consistent global system analysis have enabled a new generation of high-contrast imagers and spectrographs on large ground-based telescopes with much better performance. One of the most productive is the Spectro-Polarimetic High contrast imager for Exoplanets REsearch (SPHERE) designed and built for the ESO Very Large Telescope (VLT) in Chile. SPHERE includes an extreme adaptive optics system, a highly stable common path interface, several types of coronagraphs and three science instruments. Two of them, the Integral Field Spectrograph (IFS) and the Infra-Red Dual-band Imager and Spectrograph (IRDIS), are designed to efficiently cover the near-infrared (NIR) range in a single observation for efficient young planet search. The third one, ZIMPOL, is designed for visible (VIR) polarimetric observation to look for the reflected light of exoplanets and the light scattered by debris disks. This suite of three science instruments enables to study circumstellar environments at unprecedented angular resolution both in the visible and the near-infrared. In this work, we present the complete instrument and its on-sky performance after 4 years of operations at the VLT.
△ Less
Submitted 3 October, 2019; v1 submitted 11 February, 2019;
originally announced February 2019.
-
The MICADO first light imager for the ELT: overview, operation, simulation
Authors:
Richard Davies,
João Alves,
Yann Clénet,
Florian Lang-Bardl,
Harald Nicklas,
Jörg-Uwe Pott,
Roberto Ragazzoni,
Eline Tolstoy,
Paola Amico,
Heiko Anwand-Heerwart,
Santiago Barboza,
Lothar Barl,
Pierre Baudoz,
Ralf Bender,
Naidu Bezawada,
Peter Bizenberger,
Wilfried Boland,
Piercarlo Bonifacio,
Bruno Borgo,
Tristan Buey,
Frédéric Chapron,
Fanny Chemla,
Mathieu Cohen,
Oliver Czoske,
Vincent Deo
, et al. (76 additional authors not shown)
Abstract:
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and m…
▽ More
MICADO will enable the ELT to perform diffraction limited near-infrared observations at first light. The instrument's capabilities focus on imaging (including astrometric and high contrast) as well as single object spectroscopy. This contribution looks at how requirements from the observing modes have driven the instrument design and functionality. Using examples from specific science cases, and making use of the data simulation tool, an outline is presented of what we can expect the instrument to achieve.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
Status and performance of the THD2 bench in multi-deformable mirror configuration
Authors:
Pierre Baudoz,
Raphael Galicher,
Fabien Patru,
Olivier Dupuis,
Simone Thijs
Abstract:
The architecture of exoplanetary systems is relatively well known inward to 1 AU thanks to indirect techniques, which have allowed characterization of thousands of exoplanet orbits, masses and sometimes radii. The next step is the characterization of exoplanet atmospheres at long period, which requires direct imaging capability. While the characterization of a handful of young giant planets is fea…
▽ More
The architecture of exoplanetary systems is relatively well known inward to 1 AU thanks to indirect techniques, which have allowed characterization of thousands of exoplanet orbits, masses and sometimes radii. The next step is the characterization of exoplanet atmospheres at long period, which requires direct imaging capability. While the characterization of a handful of young giant planets is feasible with dedicated instruments like SPHERE/VLT, GPI/Gemini, SCExAO/Subaru and soon with the coronagraphic capabilities aboard JWST, the spectroscopic study of mature giant planets and lower mass planets (Neptune-like, Super Earths) requires the achievement of better coronagraphic performance. While space-based coronagraph on WFIRST-AFTA might start this study at low spectroscopic resolution, dedicated projects on large space telescope and on the ELT will be required for a more complete spectroscopic study of these faint planets. To prepare these future instruments, we developed a high contrast imaging bench called THD, then THD2 for the upgraded version using multi-DM configuration. The THD2 bench is designed to test and compare coronagraphs as well as focal plane wavefront sensors and wavefront control techniques. It can simulate the beam provided by a space telescope and soon the first stage of adaptive optics behind a ground-based telescope. In this article, we describe in details the THD2 bench and give the results of a recent comparison study of the chromatic behavior for several coronagraph on the THD2.
△ Less
Submitted 19 January, 2018;
originally announced January 2018.
-
Laboratory validation of the dual-zone phase mask coronagraph in broadband light at the high-contrast imaging THD-testbed
Authors:
J. R. Delorme,
M. N'Diaye,
R. Galicher,
K. Dohlen,
P. Baudoz,
A. Caillat,
G. Rousset,
R. Soummer,
O. Dupuis
Abstract:
Specific high contrast imaging instruments are mandatory to characterize circumstellar disks and exoplanets around nearby stars. Coronagraphs are commonly used in these facilities to reject the diffracted light of an observed star and enable the direct imaging and spectroscopy of its circumstellar environment. One important property of the coronagraph is to be able to work in broadband light.
Am…
▽ More
Specific high contrast imaging instruments are mandatory to characterize circumstellar disks and exoplanets around nearby stars. Coronagraphs are commonly used in these facilities to reject the diffracted light of an observed star and enable the direct imaging and spectroscopy of its circumstellar environment. One important property of the coronagraph is to be able to work in broadband light.
Among several proposed coronagraphs, the dual-zone phase mask coronagraph is a promising solution for starlight rejection in broadband light. In this paper, we perform the first validation of this concept in laboratory.
First, we recall the principle of the dual-zone phase mask coronagraph. Then, we describe the high-contrast imaging THD testbed, the manufacturing of the components and the quality-control procedures. Finally, we study the sensitivity of our coronagraph to low-order aberrations (inner working angle and defocus) and estimate its contrast performance. Our experimental broadband light results are compared with numerical simulations to check agreement with the performance predictions.
With the manufactured prototype and using a dark hole technique based on the self-coherent camera, we obtain contrast levels down to $2\,10^{-8}$ between 5 and 17$\,λ_0/D$ in monochromatic light (640 nm). We also reach contrast levels of $4\,10^{-8}$ between 7 and 17$λ_0/D$ in broadband ($λ_0=675$ nm, $Δλ=250$ nm and $Δλ/ λ_0 = 40$ %), which demonstrates the excellent chromatic performance of the dual-zone phase mask coronagraph.
The performance reached by the dual-zone phase mask coronagraph is promising for future high-contrast imaging instruments that aim at detecting and spectrally characterizing old or light gaseous planets.
△ Less
Submitted 27 May, 2016;
originally announced May 2016.
-
Focal plane wavefront sensor achromatization : The multireference self-coherent camera
Authors:
J. -R. Delorme,
R. Galicher,
P. Baudoz,
G. Rousset,
J. Mazoyer,
O. Dupuis
Abstract:
High contrast imaging and spectroscopy provide unique constraints for exoplanet formation models as well as for planetary atmosphere models. But this can be challenging because of the planet-to-star small angular separation and high flux ratio. Recently, optimized instruments like SPHERE and GPI were installed on 8m-class telescopes. These will probe young gazeous exoplanets at large separations (…
▽ More
High contrast imaging and spectroscopy provide unique constraints for exoplanet formation models as well as for planetary atmosphere models. But this can be challenging because of the planet-to-star small angular separation and high flux ratio. Recently, optimized instruments like SPHERE and GPI were installed on 8m-class telescopes. These will probe young gazeous exoplanets at large separations (~1au) but, because of uncalibrated aberrations that induce speckles in the coronagraphic images, they are not able to detect older and fainter planets. There are always aberrations that are slowly evolving in time. They create quasi-static speckles that cannot be calibrated a posteriori with sufficient accuracy. An active correction of these speckles is thus needed to reach very high contrast levels (>1e7). This requires a focal plane wavefront sensor. Our team proposed the SCC, the performance of which was demonstrated in the laboratory. As for all focal plane wavefront sensors, these are sensitive to chromatism and we propose an upgrade that mitigates the chromatism effects. First, we recall the principle of the SCC and we explain its limitations in polychromatic light. Then, we present and numerically study two upgrades to mitigate chromatism effects: the optical path difference method and the multireference self-coherent camera. Finally, we present laboratory tests of the latter solution.
We demonstrate in the laboratory that the MRSCC camera can be used as a focal plane wavefront sensor in polychromatic light using an 80 nm bandwidth at 640 nm. We reach a performance that is close to the chromatic limitations of our bench: contrast of 4.5e-8 between 5 and 17 lambda/D.
The performance of the MRSCC is promising for future high-contrast imaging instruments that aim to actively minimize the speckle intensity so as to detect and spectrally characterize faint old or light gaseous planets.
△ Less
Submitted 28 January, 2016;
originally announced January 2016.