Alignment and optical verification of DESHIMA 2.0 at ASTE
Authors:
A. Moerman,
K. Karatsu,
J. J. A. Baselmans,
S. O. Dabironezare,
S. Fujita,
R. Huiting,
K. Kohno,
Y. Nishimura,
F. Steenvoorde,
T. Takekoshi,
Y. Tamura,
A. Taniguchi,
S. J. C. Yates,
B. R. Brandl,
A. Endo
Abstract:
We developed, characterised, and verified an alignment method for the DESHIMA 2.0 instrument, an ultra wide-band spectrometer operating between 200-400 GHz, at the ASTE telescope. Due to the ultra-wide bandwidth of DESHIMA 2.0, we require the alignment to work across the entire spectral range. Moreover, alignment should be possible remotely, as on-site access is impractical. To fulfill these requi…
▽ More
We developed, characterised, and verified an alignment method for the DESHIMA 2.0 instrument, an ultra wide-band spectrometer operating between 200-400 GHz, at the ASTE telescope. Due to the ultra-wide bandwidth of DESHIMA 2.0, we require the alignment to work across the entire spectral range. Moreover, alignment should be possible remotely, as on-site access is impractical. To fulfill these requirements we mounted the warm optics, consisting of a modified Dragonian dual reflector system, on a motor controlled hexapod. Crucial in the alignment procedure is our sky chopper, which allows fast beam switching. Importantly, it has a small entrance and exit aperture coupling to (cold) sky, which creates a measurable signal with respect to the warm cabin environment. By scanning the instrument beam across the entrance aperture of the sky chopper using the hexapod, we found the hexapod configuration that produced the lowest signal on our detectors, implying the beam is coupled fully to cold sky and not the warm cabin. We first characterised the alignment procedure in the laboratory, where we used a vat containing liquid nitrogen as the cold source behind the sky chopper. Then, we applied the alignment procedure to DESHIMA 2.0 at ASTE, using the sky as the cold source. We used observations of Mars to calculate the aperture efficiency. We did not recover the aperture efficiencies up to design values, which we suspect to be due to a raised sidelobe level or error beam pattern. However, we did find that the alignment procedure significantly improved the aperture efficiency compared to previously reported values of the aperture efficiency of DESHIMA at ASTE, which indicates the veracity of the alignment procedure.
△ Less
Submitted 24 January, 2025;
originally announced January 2025.
Optimisation-based alignment of wideband integrated superconducting spectrometers for sub-mm astronomy
Authors:
A. Moerman,
K. Karatsu,
S. J. C. Yates,
R. Huiting,
F. Steenvoorde,
S. O. Dabironezare,
T. Takekoshi,
J. J. A. Baselmans,
B. R. Brandl,
A. Endo
Abstract:
Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the i…
▽ More
Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the instrument, which is not always guaranteed to a sufficient accuracy. We develop an alignment strategy for wideband ISSs directly utilising the sub-mm beam of the wideband ISS. The strategy should be applicable in both telescope and laboratory environments. Moreover, the strategy should deliver similar quality of the alignment across the spectral range of the wideband ISS. We measure misalignment in a quasi-optical system operating at sub-mm wavelengths using a novel phase and amplitude measurement scheme, capable of simultaneously measuring the complex beam patterns of a direct-detecting ISS across a harmonic range of frequencies. The direct detection nature of the MKID detectors in our device-under-test, DESHIMA 2.0, necessitates the use of this measurement scheme. Using geometrical optics, the measured misalignment, a mechanical hexapod, and an optimisation algorithm, we follow a numerical approach to optimise the positioning of corrective optics with respect to a given cost function. Laboratory measurements of the complex beam patterns are taken across a harmonic range between 205 and 391 GHz and simulated through a model of the ASTE telescope in order to assess the performance of the optimisation at the ASTE telescope. Laboratory measurements show that the optimised optical setup corrects for tilts and offsets of the sub-mm beam. Moreover, we find that the simulated telescope aperture efficiency is increased across the frequency range of the ISS after the optimisation.
△ Less
Submitted 23 February, 2024;
originally announced February 2024.
Lens Absorber Coupled MKIDs for Far Infrared Imaging Spectroscopy
Authors:
Shahab O. Dabironezare,
Sven van Berkel,
Pierre M. Echternach,
Peter K. Day,
Charles M. Bradford,
Jochem J. A. Baselmans
Abstract:
Future generation of astronomical imaging spectrometers are targeting the far infrared wavelengths to close the THz astronomy gap. Similar to lens antenna coupled Microwave Kinetic Inductance Detectors (MKIDs), lens absorber coupled MKIDs are a candidate for highly sensitive large format detector arrays. However, the latter is more robust to misalignment and assembly issues at THz frequencies due…
▽ More
Future generation of astronomical imaging spectrometers are targeting the far infrared wavelengths to close the THz astronomy gap. Similar to lens antenna coupled Microwave Kinetic Inductance Detectors (MKIDs), lens absorber coupled MKIDs are a candidate for highly sensitive large format detector arrays. However, the latter is more robust to misalignment and assembly issues at THz frequencies due to its incoherent detection mechanism while requiring a less complex fabrication process. In this work, the performance of such detectors is investigated. The fabrication and sensitivity measurement of several lens absorber coupled MKID array prototypes operating at 6.98 and 12 THz central frequencies is on-going.
△ Less
Submitted 27 October, 2023;
originally announced October 2023.