Alignment and optical verification of DESHIMA 2.0 at ASTE
Authors:
A. Moerman,
K. Karatsu,
J. J. A. Baselmans,
S. O. Dabironezare,
S. Fujita,
R. Huiting,
K. Kohno,
Y. Nishimura,
F. Steenvoorde,
T. Takekoshi,
Y. Tamura,
A. Taniguchi,
S. J. C. Yates,
B. R. Brandl,
A. Endo
Abstract:
We developed, characterised, and verified an alignment method for the DESHIMA 2.0 instrument, an ultra wide-band spectrometer operating between 200-400 GHz, at the ASTE telescope. Due to the ultra-wide bandwidth of DESHIMA 2.0, we require the alignment to work across the entire spectral range. Moreover, alignment should be possible remotely, as on-site access is impractical. To fulfill these requi…
▽ More
We developed, characterised, and verified an alignment method for the DESHIMA 2.0 instrument, an ultra wide-band spectrometer operating between 200-400 GHz, at the ASTE telescope. Due to the ultra-wide bandwidth of DESHIMA 2.0, we require the alignment to work across the entire spectral range. Moreover, alignment should be possible remotely, as on-site access is impractical. To fulfill these requirements we mounted the warm optics, consisting of a modified Dragonian dual reflector system, on a motor controlled hexapod. Crucial in the alignment procedure is our sky chopper, which allows fast beam switching. Importantly, it has a small entrance and exit aperture coupling to (cold) sky, which creates a measurable signal with respect to the warm cabin environment. By scanning the instrument beam across the entrance aperture of the sky chopper using the hexapod, we found the hexapod configuration that produced the lowest signal on our detectors, implying the beam is coupled fully to cold sky and not the warm cabin. We first characterised the alignment procedure in the laboratory, where we used a vat containing liquid nitrogen as the cold source behind the sky chopper. Then, we applied the alignment procedure to DESHIMA 2.0 at ASTE, using the sky as the cold source. We used observations of Mars to calculate the aperture efficiency. We did not recover the aperture efficiencies up to design values, which we suspect to be due to a raised sidelobe level or error beam pattern. However, we did find that the alignment procedure significantly improved the aperture efficiency compared to previously reported values of the aperture efficiency of DESHIMA at ASTE, which indicates the veracity of the alignment procedure.
△ Less
Submitted 24 January, 2025;
originally announced January 2025.
-
A 25-micron single photon sensitive kinetic inductance detector
Authors:
Peter K. Day,
Nicholas F. Cothard,
Christopher Albert,
Logan Foote,
Elijah Kane,
Byeong H. Eom,
Ritoban Basu Thakur,
Reinier M. J. Janssen,
Andrew Beyer,
Pierre Echternach,
Sven van Berkel,
Steven Hailey-Dunsheath,
Thomas R. Stevenson,
Shahab Dabironezare,
Jochem J. A. Baselmans,
Jason Glenn,
C. Matt Bradford,
Henry G. Leduc
Abstract:
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integ…
▽ More
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
△ Less
Submitted 14 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Optimisation-based alignment of wideband integrated superconducting spectrometers for sub-mm astronomy
Authors:
A. Moerman,
K. Karatsu,
S. J. C. Yates,
R. Huiting,
F. Steenvoorde,
S. O. Dabironezare,
T. Takekoshi,
J. J. A. Baselmans,
B. R. Brandl,
A. Endo
Abstract:
Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the i…
▽ More
Integrated superconducting spectrometers (ISSs) for wideband sub-mm astronomy utilise quasi-optical systems for coupling radiation from the telescope to the instrument. Misalignment in these systems is detrimental to the system performance. The common method of using an optical laser to align the quasi-optical components requires accurate alignment of the laser to the sub-mm beam coming from the instrument, which is not always guaranteed to a sufficient accuracy. We develop an alignment strategy for wideband ISSs directly utilising the sub-mm beam of the wideband ISS. The strategy should be applicable in both telescope and laboratory environments. Moreover, the strategy should deliver similar quality of the alignment across the spectral range of the wideband ISS. We measure misalignment in a quasi-optical system operating at sub-mm wavelengths using a novel phase and amplitude measurement scheme, capable of simultaneously measuring the complex beam patterns of a direct-detecting ISS across a harmonic range of frequencies. The direct detection nature of the MKID detectors in our device-under-test, DESHIMA 2.0, necessitates the use of this measurement scheme. Using geometrical optics, the measured misalignment, a mechanical hexapod, and an optimisation algorithm, we follow a numerical approach to optimise the positioning of corrective optics with respect to a given cost function. Laboratory measurements of the complex beam patterns are taken across a harmonic range between 205 and 391 GHz and simulated through a model of the ASTE telescope in order to assess the performance of the optimisation at the ASTE telescope. Laboratory measurements show that the optimised optical setup corrects for tilts and offsets of the sub-mm beam. Moreover, we find that the simulated telescope aperture efficiency is increased across the frequency range of the ISS after the optimisation.
△ Less
Submitted 23 February, 2024;
originally announced February 2024.
-
Characterization of a Far-Infrared Kinetic Inductance Detector Prototype for PRIMA
Authors:
Steven Hailey-Dunsheath,
Sven van Berkel,
Andrew E. Beyer,
Logan Foote,
Reinier M. J. Janssen,
Henry G. LeDuc,
Pierre M. Echternach,
Charles M. Bradford,
Jochem J. A. Baselmans,
Shahab Dabironezare,
Peter K. Day,
Nicholas F. Cothard,
Jason Glenn
Abstract:
The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background afforded by a cold telescope, spectroscopy with PRIMA requires detectors with a noise equivalent power (NEP) better than $1 \times 10^{-19}$ W Hz$^{-1/2}$. To m…
▽ More
The PRobe far-Infrared Mission for Astrophysics (PRIMA) is under study as a potential far-IR space mission, featuring actively cooled optics, and both imaging and spectroscopic instrumentation. To fully take advantage of the low background afforded by a cold telescope, spectroscopy with PRIMA requires detectors with a noise equivalent power (NEP) better than $1 \times 10^{-19}$ W Hz$^{-1/2}$. To meet this goal we are developing large format arrays of kinetic inductance detectors (KIDs) to work across the $25-250$ micron range. Here we present the design and characterization of a single pixel prototype detector optimized for $210$ micron. The KID consists of a lens-coupled aluminum inductor-absorber connected to a niobium interdigitated capacitor to form a 2 GHz resonator. We have fabricated a small array with 28 KIDs, and we measure the performance of one of these detectors with an optical loading in the $0.01 - 300$ aW range. At low loading the detector achieves an NEP of $9\times10^{-20}$ W Hz$^{-1/2}$ at a 10 Hz readout frequency. An extrapolation of these measurements suggests this detector may remain photon noise limited at up to 20 fW of loading, offering a high dynamic range for PRIMA observations of bright astronomical sources.
△ Less
Submitted 5 May, 2025; v1 submitted 6 November, 2023;
originally announced November 2023.
-
Lens Absorber Coupled MKIDs for Far Infrared Imaging Spectroscopy
Authors:
Shahab O. Dabironezare,
Sven van Berkel,
Pierre M. Echternach,
Peter K. Day,
Charles M. Bradford,
Jochem J. A. Baselmans
Abstract:
Future generation of astronomical imaging spectrometers are targeting the far infrared wavelengths to close the THz astronomy gap. Similar to lens antenna coupled Microwave Kinetic Inductance Detectors (MKIDs), lens absorber coupled MKIDs are a candidate for highly sensitive large format detector arrays. However, the latter is more robust to misalignment and assembly issues at THz frequencies due…
▽ More
Future generation of astronomical imaging spectrometers are targeting the far infrared wavelengths to close the THz astronomy gap. Similar to lens antenna coupled Microwave Kinetic Inductance Detectors (MKIDs), lens absorber coupled MKIDs are a candidate for highly sensitive large format detector arrays. However, the latter is more robust to misalignment and assembly issues at THz frequencies due to its incoherent detection mechanism while requiring a less complex fabrication process. In this work, the performance of such detectors is investigated. The fabrication and sensitivity measurement of several lens absorber coupled MKID array prototypes operating at 6.98 and 12 THz central frequencies is on-going.
△ Less
Submitted 27 October, 2023;
originally announced October 2023.
-
DESHIMA 2.0: development of an integrated superconducting spectrometer for science-grade astronomical observations
Authors:
Akio Taniguchi,
Tom J. L. C. Bakx,
Jochem J. A. Baselmans,
Robert Huiting,
Kenichi Karatsu,
Nuria Llombart,
Matus Rybak,
Tatsuya Takekoshi,
Yoichi Tamura,
Hiroki Akamatsu,
Stefanie Brackenhoff,
Juan Bueno,
Bruno T. Buijtendorp,
Shahab Dabironezare,
Anne-Kee Doing,
Yasunori Fujii,
Kazuyuki Fujita,
Matthijs Gouwerok,
Sebastian Hähnle,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Tetsu Kitayama,
Kotaro Kohno,
Akira Kouchi
, et al. (10 additional authors not shown)
Abstract:
Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed…
▽ More
Integrated superconducting spectrometer (ISS) technology will enable ultra-wideband, integral-field spectroscopy for (sub)millimeter-wave astronomy, in particular, for uncovering the dust-obscured cosmic star formation and galaxy evolution over cosmic time. Here we present the development of DESHIMA 2.0, an ISS for ultra-wideband spectroscopy toward high-redshift galaxies. DESHIMA 2.0 is designed to observe the 220-440 GHz band in a single shot, corresponding to a redshift range of $z$=3.3-7.6 for the ionized carbon emission ([C II] 158 $μ$m). The first-light experiment of DESHIMA 1.0, using the 332-377 GHz band, has shown an excellent agreement among the on-sky measurements, the lab measurements, and the design. As a successor to DESHIMA 1.0, we plan the commissioning and the scientific observation campaign of DESHIMA 2.0 on the ASTE 10-m telescope in 2023. Ongoing upgrades for the full octave-bandwidth system include the wideband 347-channel chip design and the wideband quasi-optical system. For efficient measurements, we also develop the observation strategy using the mechanical fast sky-position chopper and the sky-noise removal technique based on a novel data-scientific approach. In the paper, we show the recent status of the upgrades and the plans for the scientific observation campaign.
△ Less
Submitted 4 October, 2022; v1 submitted 27 October, 2021;
originally announced October 2021.