UCGretina GEANT4 Simulation of the GRETINA Gamma-Ray Energy Tracking Array
Authors:
L. A. Riley,
D. Weisshaar,
H. L. Crawford,
M. L. Agiorgousis,
C. M. Campbell,
M. Cromaz,
P. Fallon,
A. Gade,
S. D. Gregory,
E. B. Haldeman,
L. R. Jarvis,
E. D. Lawson-John,
B. Roberts,
B. V. Sadler,
C. G. Stine
Abstract:
UCGretina, a GEANT4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton co…
▽ More
UCGretina, a GEANT4 simulation of the GRETINA gamma-ray tracking array of highly-segmented high-purity germanium detectors is described. We have developed a model of the array, in particular of the Quad Module and the capsules, that gives good agreement between simulated and measured photopeak efficiencies over a broad range of gamma-ray energies and reproduces the shape of the measured Compton continuum. Both of these features are needed in order to accurately extract gamma-ray yields from spectra collected in in-beam gamma-ray spectroscopy measurements with beams traveling at $v/c \gtrsim 0.3$ at the National Superconducting Cyclotron Laboratory and the Facility for Rare Isotope Beams. In the process of developing the model, we determined that millimeter-scale layers of passive germanium surrounding the active volumes of the simulated crystals must be included in order to reproduce measured photopeak efficiencies. We adopted a simple model of effective passive layers and developed heuristic methods of determining passive-layer thicknesses by comparison of simulations and measurements for a single crystal and for the full array. Prospects for future development of the model are discussed.
△ Less
Submitted 17 April, 2021;
originally announced April 2021.
Experimental Constraint on Stellar Electron-Capture Rates from the ${}^{88}\text{Sr}(t,{}^{3}\text{He}+γ){}^{88}\text{Rb}$ reaction at 115 MeV/u
Authors:
J. C. Zamora,
R. G. T. Zegers,
Sam M. Austin,
D. Bazin,
B. A. Brown,
P. C. Bender,
H. L. Crawford,
J. Engel,
A. Falduto,
A. Gade,
P. Gastis,
B. Gao,
T. Ginter,
C. J. Guess,
S. Lipschutz,
B. Longfellow,
A. O. Macchiavelli,
K. Miki,
E. Ney,
S. Noji,
J. Pereira,
J. Schmitt,
C. Sullivan,
R. Titus,
D. Weisshaar
Abstract:
The Gamow-Teller strength distribution from ${}^{88}$Sr was extracted from a $(t,{}^{3}\text{He}+γ)$ experiment at 115 MeV/$u$ to constrain estimates for the electron-capture rates on nuclei around $N=50$, between and including $^{78}$Ni and $^{88}$Sr, which are important for the late evolution of core-collapse supernovae. The observed strength below an excitation energy of 8 MeV was consistent wi…
▽ More
The Gamow-Teller strength distribution from ${}^{88}$Sr was extracted from a $(t,{}^{3}\text{He}+γ)$ experiment at 115 MeV/$u$ to constrain estimates for the electron-capture rates on nuclei around $N=50$, between and including $^{78}$Ni and $^{88}$Sr, which are important for the late evolution of core-collapse supernovae. The observed strength below an excitation energy of 8 MeV was consistent with zero and below 10 MeV amounted to $0.1\pm0.05$. Except for a very-weak transition that could come from the 2.231-MeV $1^{+}$ state, no $γ$ lines that could be associated with the decay of known $1^{+}$ states were identified. The derived electron-capture rate from the measured strength distribution is more than an order of magnitude smaller than rates based on the single-state approximation presently used in astrophysical simulations for most nuclei near $N=50$. Rates based on shell-model and quasiparticle random-phase approximation calculations that account for Pauli blocking and core-polarization effects provide better estimates than the single-state approximation, although a relatively strong transition to the first $1^{+}$ state in $^{88}$Rb is not observed in the data. Pauli unblocking effects due to high stellar temperatures could partially counter the low electron-capture rates. The new data serves as a zero-temperature benchmark for constraining models used to estimate such effects.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.