Background Rejection in the DMTPC Dark Matter Search Using Charge Signals
Authors:
J. P. Lopez,
S. Ahlen,
J. Battat,
T. Caldwell,
M. Chernicoff,
C. Deaconu,
D. Dujmic,
A. Dushkin,
W. Fedus,
P. Fisher,
F. Golub,
S. Henderson,
A. Inglis,
A. Kaboth,
G. Kohse,
L. Kirsch,
R. Lanza,
A. Lee,
J. Monroe,
H. Ouyang,
T. Sahin,
G. Sciolla,
N. Skvorodnev,
H. Tomita,
H. Wellenstein
, et al. (3 additional authors not shown)
Abstract:
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that…
▽ More
The Dark Matter Time Projection Chamber (DMTPC) collaboration is developing low-pressure gas TPC detectors for measuring WIMP-nucleon interactions. Optical readout with CCD cameras allows for the detection for the daily modulation in the direction of the dark matter wind, while several charge readout channels allow for the measurement of additional recoil properties. In this article, we show that the addition of the charge readout analysis to the CCD allows us too obtain a statistics-limited 90% C.L. upper limit on the $e^-$ rejection factor of $5.6\times10^{-6}$ for recoils with energies between 40 and 200 keV$_{\mathrm{ee}}$. In addition, requiring coincidence between charge signals and light in the CCD reduces CCD-specific backgrounds by more than two orders of magnitude.
△ Less
Submitted 15 September, 2011;
originally announced September 2011.
Dark Matter Time Projection Chamber: Recent R&D Results
Authors:
J. B. R. Battat,
S. Ahlen,
M. Chernicoff,
C. Deaconu,
D. Dujmic,
A. Dushkin,
P. Fisher,
S. Henderson,
A. Inglis,
A. Kaboth,
L. Kirsch,
J. P. Lopez,
J. Monroe,
H. Ouyang,
G. Sciolla,
H. Tomita,
H. Wellenstein
Abstract:
The Dark Matter Time Projection Chamber collaboration recently reported a dark matter limit obtained with a 10 liter time projection chamber filled with CF4 gas. The 10 liter detector was capable of 2D tracking (perpendicular to the drift direction) and 2D fiducialization, and only used information from two CCD cameras when identifying tracks and rejecting backgrounds. Since that time, the collabo…
▽ More
The Dark Matter Time Projection Chamber collaboration recently reported a dark matter limit obtained with a 10 liter time projection chamber filled with CF4 gas. The 10 liter detector was capable of 2D tracking (perpendicular to the drift direction) and 2D fiducialization, and only used information from two CCD cameras when identifying tracks and rejecting backgrounds. Since that time, the collaboration has explored the potential benefits of photomultiplier tube and electronic charge readout to achieve 3D tracking, and particle identification for background rejection. The latest results of this effort is described here.
△ Less
Submitted 18 September, 2011; v1 submitted 15 September, 2011;
originally announced September 2011.