-
High-Spectral Resolution Dark Holes: Concept, Results, and Promise
Authors:
William Thompson,
Adam B. Johnson,
Christian Marois,
Olivier Lardière,
Frédéric Grandmont,
Tim Hardy,
Kris Caputa,
Colin Bradley,
Garima Singh
Abstract:
Next generation high contrast imaging instruments face a challenging trade off: they will be required to deliver data with high spectral resolution at a relatively fast cadence (minutes) and across a wide field of view (arcseconds). For instruments that employ focal plane wavefront sensing and therefore require super-Nyquist sampling, these requirements cannot simultaneously be met with a traditio…
▽ More
Next generation high contrast imaging instruments face a challenging trade off: they will be required to deliver data with high spectral resolution at a relatively fast cadence (minutes) and across a wide field of view (arcseconds). For instruments that employ focal plane wavefront sensing and therefore require super-Nyquist sampling, these requirements cannot simultaneously be met with a traditional lenslet integral field spectrograph (IFU). For the SPIDERS pathfinder instrument, we are demonstrating an imaging Fourier transform spectrograph (IFTS) that offers a different set of tradeoffs than a lenslet IFU, delivering up to R20,000 spectral resolution across a dark hole. We present preliminary results from the SPIDERS IFTS including a chromaticity analysis of its dark hole and demonstrate a spectral differential imaging (SDI) improvement of up to 40 $\times$, and a first application of spectro-coherent differential imaging, combining both coherent differential imaging (CDI) and SDI.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
Sample clock frequency offset (SCFO) Resolution Team 3 (RT-3) investigation
Authors:
Brent Carlson,
Paul Boven,
Kris Caputa
Abstract:
This Resolution Team 3 (RT-3) report contains the results of the investigation of key aspects of the proposed Sample Clock Frequency Offset (SCFO) scheme for the Mid SKA1 telescope. This is a scheme, first proposed by one author (Carlson) at a meeting at the SKAO 25-Jan-2013, to digitize the analog signal at each antenna at a slightly different sample rate and transmit the data to the CSP Mid.CBF…
▽ More
This Resolution Team 3 (RT-3) report contains the results of the investigation of key aspects of the proposed Sample Clock Frequency Offset (SCFO) scheme for the Mid SKA1 telescope. This is a scheme, first proposed by one author (Carlson) at a meeting at the SKAO 25-Jan-2013, to digitize the analog signal at each antenna at a slightly different sample rate and transmit the data to the CSP Mid.CBF for subsequent digital re-sampling to a common sample clock frequency before channelization, correlation, and beamforming. The primary purpose for doing this is to cause de-correlation of sample clock-related self-interference to be able to improve correlated and beamformed signal quality. This report includes an investigation of the efficacy of the method, investigation of its implementation by SADT, DISH, and CSP, presentation of further supporting modeling results augmenting the original modeling work, a note on expansion to SKA-2, as well as possible draw-backs and concerns. Finally, there are potential additional benefits in signal quality in implementing the SCFO scheme, in particular de-correlation of aliased RFI (particularly for Nyquist Zone-2 digitized signals) as well as relaxation of signal-chain anti-aliasing filters transition band roll-off and reject band attenuation prior to digitization in the antenna.
△ Less
Submitted 18 December, 2018;
originally announced December 2018.
-
NFIRAOS First Facility AO System for the Thirty Meter Telescope
Authors:
Glen Herriot,
David Andersen,
Jenny Atwood,
Corinne Boyer,
Peter Byrnes,
Kris Caputa,
Brent Ellerbroek,
Luc Gilles,
Alexis Hill,
Zoran Ljusic,
John Pazder,
Matthias Rosensteiner,
Malcolm Smith,
Paolo Spano,
Kei Szeto,
Jean-Pierre Véran,
Ivan Wevers,
Lianqi Wang,
Robert Wooff
Abstract:
NFIRAOS, the Thirty Meter Telescope's first adaptive optics system is an order 60x60 Multi-Conjugate AO system with two deformable mirrors. Although most observing will use 6 laser guide stars, it also has an NGS-only mode. Uniquely, NFIRAOS is cooled to -30 C to reduce thermal background. NFIRAOS delivers a 2-arcminute beam to three client instruments, and relies on up to three IR WFSs in each in…
▽ More
NFIRAOS, the Thirty Meter Telescope's first adaptive optics system is an order 60x60 Multi-Conjugate AO system with two deformable mirrors. Although most observing will use 6 laser guide stars, it also has an NGS-only mode. Uniquely, NFIRAOS is cooled to -30 C to reduce thermal background. NFIRAOS delivers a 2-arcminute beam to three client instruments, and relies on up to three IR WFSs in each instrument. We present recent work including: robust automated acquisition on these IR WFSs; trade-off studies for a common-size of deformable mirror; real-time computing architectures; simplified designs for high-order NGS-mode wavefront sensing; modest upgrade concepts for high-contrast imaging.
△ Less
Submitted 19 August, 2014;
originally announced August 2014.