Cosmic ray susceptibility of the Terahertz Intensity Mapper detector arrays
Authors:
Lun-Jun Liu,
Reinier M. J. Janssen,
Bruce Bumble,
Elijah Kane,
Logan M. Foote,
Charles M. Bradford,
Steven Hailey-Dunsheath,
Shubh Agrawal,
James E. Aguirre,
Hrushi Athreya,
Justin S. Bracks,
Brockton S. Brendal,
Anthony J. Corso,
Jeffrey P. Filippini,
Jianyang Fu,
Christopher E. Groppi,
Dylan Joralmon,
Ryan P. Keenan,
Mikolaj Kowalik,
Ian N. Lowe,
Alex Manduca,
Daniel P. Marrone,
Philip D. Mauskopf,
Evan C. Mayer,
Rong Nie
, et al. (4 additional authors not shown)
Abstract:
We report on the effects of cosmic ray interactions with the Kinetic Inductance Detector (KID) based focal plane array for the Terahertz Intensity Mapper (TIM). TIM is a NASA-funded balloon-borne experiment designed to probe the peak of the star formation in the Universe. It employs two spectroscopic bands, each equipped with a focal plane of four $\sim\,$900-pixel, KID-based array chips. Measurem…
▽ More
We report on the effects of cosmic ray interactions with the Kinetic Inductance Detector (KID) based focal plane array for the Terahertz Intensity Mapper (TIM). TIM is a NASA-funded balloon-borne experiment designed to probe the peak of the star formation in the Universe. It employs two spectroscopic bands, each equipped with a focal plane of four $\sim\,$900-pixel, KID-based array chips. Measurements of an 864-pixel TIM array shows 791 resonators in a 0.5$\,$GHz bandwidth. We discuss challenges with resonator calibration caused by this high multiplexing density. We robustly identify the physical positions of 788 (99.6$\,$%) detectors using a custom LED-based identification scheme. Using this information we show that cosmic ray events occur at a rate of 2.1$\,\mathrm{events/min/cm^2}$ in our array. 66$\,$% of the events affect a single pixel, and another 33$\,$% affect $<\,$5 KIDs per event spread over a 0.66$\,\mathrm{cm^2}$ region (2 pixel pitches in radius). We observe a total cosmic ray dead fraction of 0.0011$\,$%, and predict that the maximum possible in-flight dead fraction is $\sim\,$0.165$\,$%, which demonstrates our design will be robust against these high-energy events.
△ Less
Submitted 24 July, 2024;
originally announced July 2024.
-
Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier
Authors:
Karthik Ramanathan,
Osmond Wen,
Taylor Aralis,
Ritoban Basu Thakur,
Bruce Bumble,
Yen-Yung Chang,
Peter K. Day,
Byeong Ho Eom,
Henry G. LeDuc,
Brandon J. Sandoval,
Ryan Stephenson,
Sunil R. Golwala
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers,…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Travelling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ~5x improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing O(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.
△ Less
Submitted 8 February, 2024;
originally announced February 2024.
-
SCExAO and Keck Direct Imaging Discovery of a Low-Mass Companion Around the Accelerating F5 Star HIP 5319
Authors:
Noah Swimmer,
Thayne Currie,
Sarah Steiger,
Gregory Mirek Brandt,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Taylor Tobin,
Tyler D. Groff,
Julien Lozi,
John I. Bailey III,
Alexander B. Walter,
Neelay Fruitwala,
Nicholas Zobrist,
Jennifer Pearl Smith,
Gregoire Coiffard,
Rupert Dodkins,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Nour Skaf,
Vincent Deo,
Nemanja Jovanovic
, et al. (4 additional authors not shown)
Abstract:
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of…
▽ More
We present the direct imaging discovery of a low-mass companion to the nearby accelerating F star, HIP 5319, using SCExAO coupled with the CHARIS, VAMPIRES, and MEC instruments in addition to Keck/NIRC2 imaging. CHARIS $JHK$ (1.1-2.4 $μ$m) spectroscopic data combined with VAMPIRES 750 nm, MEC $Y$, and NIRC2 $L_{\rm p}$ photometry is best matched by an M3--M7 object with an effective temperature of T=3200 K and surface gravity log($g$)=5.5. Using the relative astrometry for HIP 5319 B from CHARIS and NIRC2 and absolute astrometry for the primary from $Gaia$ and $Hipparcos$ and adopting a log-normal prior assumption for the companion mass, we measure a dynamical mass for HIP 5319 B of $31^{+35}_{-11}M_{\rm J}$, a semimajor axis of $18.6^{+10}_{-4.1}$ au, an inclination of $69.4^{+5.6}_{-15}$ degrees, and an eccentricity of $0.42^{+0.39}_{-0.29}$. However, using an alternate prior for our dynamical model yields a much higher mass of 128$^{+127}_{-88}M_{\rm J}$. Using data taken with the LCOGT NRES instrument we also show that the primary HIP 5319 A is a single star in contrast to previous characterizations of the system as a spectroscopic binary. This work underscores the importance of assumed priors in dynamical models for companions detected with imaging and astrometry and the need to have an updated inventory of system measurements.
△ Less
Submitted 30 July, 2022;
originally announced August 2022.
-
Identifying drivers of energy resolution variation in multi-KID phonon-mediated detectors
Authors:
Karthik Ramanathan,
Taylor Aralis,
Ritoban Basu Thakur,
Bruce Bumble,
Yen-Yung Chang,
Osmond Wen,
Sunil Golwala
Abstract:
Phonon-mediated particle detectors employing Kinetic Inductance Detectors (KIDs) on Silicon substrates have demonstrated both O(10) eV energy resolution and mm position resolution, making them strong candidates for instrumenting next generation rare-event experiments such as in looking for dark matter or in neutrino measurements. Previous work has demonstrated the performance of an 80-KID array on…
▽ More
Phonon-mediated particle detectors employing Kinetic Inductance Detectors (KIDs) on Silicon substrates have demonstrated both O(10) eV energy resolution and mm position resolution, making them strong candidates for instrumenting next generation rare-event experiments such as in looking for dark matter or in neutrino measurements. Previous work has demonstrated the performance of an 80-KID array on a Si wafer, however current energy resolution measurements show a 25x difference between otherwise identical KIDs on the same wafer - between 5 to 125 eV on energy absorbed by the KID. Here, we use a first principles approach and attempt to identify the drivers behind the resolution variation. In particular, we analyze a subset of 8 KIDs using the unique approach of pulsing neighboring KIDs to generate signals in the target. We tentatively identify differences in quality factor terms as the likely culprit for the observed variation.
△ Less
Submitted 8 June, 2022; v1 submitted 3 November, 2021;
originally announced November 2021.
-
SCExAO/MEC and CHARIS Discovery of a Low Mass, 6 AU-Separation Companion to HIP 109427 using Stochastic Speckle Discrimination and High-Contrast Spectroscopy
Authors:
Sarah Steiger,
Thayne Currie,
Timothy D. Brandt,
Olivier Guyon,
Masayuki Kuzuhara,
Jeffrey Chilcote,
Tyler D. Groff,
Julien Lozi,
Alexander B. Walter,
Neelay Fruitwala,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Clint Bockstiegel,
Seth R. Meeker,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Sebastien Vievard,
Ananya Sahoo
, et al. (6 additional authors not shown)
Abstract:
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band a…
▽ More
We report the direct imaging discovery of a low-mass companion to the nearby accelerating A star, HIP 109427, with the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument coupled with the MKID Exoplanet Camera (MEC) and CHARIS integral field spectrograph. CHARIS data reduced with reference star PSF subtraction yield 1.1-2.4 $μ$m spectra. MEC reveals the companion in $Y$ and $J$ band at a comparable signal-to-noise ratio using stochastic speckle discrimination, with no PSF subtraction techniques. Combined with complementary follow-up $L_{\rm p}$ photometry from Keck/NIRC2, the SCExAO data favors a spectral type, effective temperature, and luminosity of M4-M5.5, 3000-3200 $K$, and $\log_{10}(L/L_{\rm \odot}) = -2.28^{+0.04}_{-0.04}$, respectively. Relative astrometry of HIP 109427 B from SCExAO/CHARIS and Keck/NIRC2, and complementary Gaia-Hipparcos absolute astrometry of the primary favor a semimajor axis of $6.55^{+3.0}_{-0.48}$ au, an eccentricity of $0.54^{+0.28}_{-0.15}$, an inclination of $66.7^{+8.5}_{-14}$ degrees, and a dynamical mass of $0.280^{+0.18}_{-0.059}$ $M_{\odot}$. This work shows the potential for extreme AO systems to utilize speckle statistics in addition to widely-used post-processing methods to directly image faint companions to nearby stars near the telescope diffraction limit.
△ Less
Submitted 12 July, 2021; v1 submitted 11 March, 2021;
originally announced March 2021.
-
Improving the dynamic range of single photon counting kinetic inductance detectors
Authors:
Nicholas Zobrist,
Nikita Klimovich,
Byeong Ho Eom,
Grégoire Coiffard,
Miguel Daal,
Noah Swimmer,
Sarah Steiger,
Bruce Bumble,
Henry G. LeDuc,
Peter Day,
Benjamin A. Mazin
Abstract:
We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the c…
▽ More
We develop a simple coordinate transformation which can be employed to compensate for the nonlinearity introduced by a Microwave Kinetic Inductance Detector's (MKID) homodyne readout scheme. This coordinate system is compared to the canonically used polar coordinates and is shown to improve the performance of the filtering method often used to estimate a photon's energy. For a detector where the coordinate nonlinearity is primarily responsible for limiting its resolving power, this technique leads to increased dynamic range, which we show by applying the transformation to data from a hafnium MKID designed to be sensitive to photons with wavelengths in the 800 to 1300 nm range. The new coordinates allow the detector to resolve photons with wavelengths down to 400 nm, raising the resolving power at that wavelength from 6.8 to 17.
△ Less
Submitted 9 December, 2020;
originally announced December 2020.
-
The MKID Exoplanet Camera for Subaru SCExAO
Authors:
Alexander B. Walter,
Neelay Fruitwala,
Sarah Steiger,
John I. Bailey III,
Nicholas Zobrist,
Noah Swimmer,
Isabel Lipartito,
Jennifer Pearl Smith,
Seth R. Meeker,
Clint Bockstiegel,
Gregoire Coiffard,
Rupert Dodkins,
Paul Szypryt,
Kristina K. Davis,
Miguel Daal,
Bruce Bumble,
Giulia Collura,
Olivier Guyon,
Julien Lozi,
Sebastien Vievard,
Nemanja Jovanovic,
Frantz Martinache,
Thayne Currie,
Benjamin A. Mazin
Abstract:
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument a…
▽ More
We present the MKID Exoplanet Camera (MEC), a z through J band (800 - 1400 nm) integral field spectrograph located behind The Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) at the Subaru Telescope on Maunakea that utilizes Microwave Kinetic Inductance Detectors (MKIDs) as the enabling technology for high contrast imaging. MEC is the first permanently deployed near-infrared MKID instrument and is designed to operate both as an IFU, and as a focal plane wavefront sensor in a multi-kHz feedback loop with SCExAO. The read noise free, fast time domain information attainable by MKIDs allows for the direct probing of fast speckle fluctuations that currently limit the performance of most high contrast imaging systems on the ground and will help MEC achieve its ultimate goal of reaching contrasts of $10^{-7}$ at 2$λ/ D$. Here we outline the instrument details of MEC including the hardware, firmware, and data reduction and analysis pipeline. We then discuss MEC's current on-sky performance and end with future upgrades and plans.
△ Less
Submitted 23 October, 2020;
originally announced October 2020.
-
Characterization of sputtered hafnium thin films for high quality factor microwave kinetic inductance detectors
Authors:
G. Coiffard,
M. Daal,
N. Zobrist,
N. Swimmer,
S. Steiger,
B. Bumble,
B. A. Mazin
Abstract:
Hafnium is an elemental superconductor which crystallizes in a hexagonal close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and has a high normal state resistivity around $90 μΩ. cm$. In Microwave Kinetic Inductance Detectors (MKIDs), these properties are advantageous since they allow for creating detectors sensitive to optical and near infra-red radiation. In this work, w…
▽ More
Hafnium is an elemental superconductor which crystallizes in a hexagonal close packed structure, has a transition temperature $T_{C} \simeq 400 mK$, and has a high normal state resistivity around $90 μΩ. cm$. In Microwave Kinetic Inductance Detectors (MKIDs), these properties are advantageous since they allow for creating detectors sensitive to optical and near infra-red radiation. In this work, we study how sputter conditions and especially the power applied to the target during the deposition, affect the hafnium $T_{C}$, resistivity, stress, texture and preferred crystal orientation. We find that the position of the target with respect to the substrate strongly affects the orientation of the crystallites in the films and the internal quality factor, $Q_{i}$, of MKIDs fabricated from the films. In particular, we demonstrate that a DC magnetron sputter deposition at a normal angle of incidence, low pressure, and low plasma power promotes the growth of compressive (002)-oriented films and that such films can be used to make high quality factor MKIDs with $Q_{i}$ up to 600,000.
△ Less
Submitted 1 April, 2020;
originally announced April 2020.
-
Design and Performance of Hafnium Optical and Near-IR Kinetic Inductance Detectors
Authors:
Nicholas Zobrist,
Grégoire Coiffard,
Bruce Bumble,
Noah Swimmer,
Sarah Steiger,
Miguel Daal,
Giulia Collura,
Alex B. Walter,
Clint Bockstiegel,
Neelay Fruitwala,
Isabel Lipartito,
Benjamin A. Mazin
Abstract:
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $μΩ$ cm with an RRR = 1.6. Resonators on the device displayed internal quality fa…
▽ More
We report on the design and performance of Microwave Kinetic Inductance Detectors (MKIDs) sensitive to single photons in the optical to near-infrared range using hafnium as the sensor material. Our test device had a superconducting transition temperature of 395 mK and a room temperature normal state resistivity of 97 $μΩ$ cm with an RRR = 1.6. Resonators on the device displayed internal quality factors of around 200,000. Similar to the analysis of MKIDs made from other highly resistive superconductors, we find that modeling the temperature response of the detector requires an extra broadening parameter in the superconducting density of states. Finally, we show that this material and design is compatible with a full-array fabrication process which resulted in pixels with decay times of about 40 $μ$s and resolving powers of ~9 at 800 nm.
△ Less
Submitted 14 November, 2019;
originally announced November 2019.
-
Optical and Near-IR Microwave Kinetic Inductance Detectors (MKIDs) in the 2020s
Authors:
Benjamin A. Mazin,
Jeb Bailey,
Jo Bartlett,
Clint Bockstiegel,
Bruce Bumble,
Gregoire Coiffard,
Thayne Currie,
Miguel Daal,
Kristina Davis,
Rupert Dodkins,
Neelay Fruitwala,
Nemanja Jovanovic,
Isabel Lipartito,
Julien Lozi,
Jared Males,
Dimitri Mawet,
Seth Meeker,
Kieran O'Brien,
Michael Rich,
Jenny Smith,
Sarah Steiger,
Noah Swimmer,
Alex Walter,
Nick Zobrist,
Jonas Zmuidzinas
Abstract:
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
Optical and near-IR Microwave Kinetic Inductance Detectors, or MKIDs, are superconducting photon counting detectors capable of measuring the energy and arrival time of individual OIR photons without read noise or dark current. In this whitepaper we will discuss the current status of OIR MKIDs and MKID-based instruments.
△ Less
Submitted 7 August, 2019;
originally announced August 2019.
-
Wide-band Parametric Amplifier Readout and Resolution of Optical Microwave Kinetic Inductance Detectors
Authors:
Nicholas Zobrist,
Byeong Ho Eom,
Peter Day,
Benjamin A. Mazin,
Seth R. Meeker,
Bruce Bumble,
Henry G. LeDuc,
Gérgoire Coiffard,
Paul Szypryt,
Neelay Fruitwala,
Isabel Lipartito,
Clint Bockstiegel
Abstract:
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based trav…
▽ More
The energy resolution of a single photon counting Microwave Kinetic Inductance Detector (MKID) can be degraded by noise coming from the primary low temperature amplifier in the detector's readout system. Until recently, quantum limited amplifiers have been incompatible with these detectors due to dynamic range, power, and bandwidth constraints. However, we show that a kinetic inductance based traveling wave parametric amplifier can be used for this application and reaches the quantum limit. The total system noise for this readout scheme was equal to ~2.1 in units of quanta. For incident photons in the 800 to 1300 nm range, the amplifier increased the average resolving power of the detector from ~6.7 to 9.3 at which point the resolution becomes limited by noise on the pulse height of the signal. Noise measurements suggest that a resolving power of up to 25 is possible if redesigned detectors can remove this additional noise source.
△ Less
Submitted 6 July, 2019;
originally announced July 2019.
-
DARKNESS: A Microwave Kinetic Inductance Detector Integral Field Spectrograph for High-Contrast Astronomy
Authors:
Seth R. Meeker,
Benjamin A. Mazin,
Alex B. Walter,
Paschal Strader,
Neelay Fruitwala,
Clint Bockstiegel,
Paul Szypryt,
Gerhard Ulbricht,
Gregoire Coiffard,
Bruce Bumble,
Gustavo Cancelo,
Ted Zmuda,
Ken Treptow,
Neal Wilcer,
Giulia Collura,
Rupert Dodkins,
Isabel Lipartito,
Nicholas Zobrist,
Michael Bottom,
J. Chris Shelton,
Dimitri Mawet,
Julian C. van Eyken,
Gautam Vasisht,
Eugene Serabyn
Abstract:
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques an…
▽ More
We present DARKNESS (the DARK-speckle Near-infrared Energy-resolving Superconducting Spectrophotometer), the first of several planned integral field spectrographs to use optical/near-infrared Microwave Kinetic Inductance Detectors (MKIDs) for high-contrast imaging. The photon counting and simultaneous low-resolution spectroscopy provided by MKIDs will enable real-time speckle control techniques and post-processing speckle suppression at framerates capable of resolving the atmospheric speckles that currently limit high-contrast imaging from the ground. DARKNESS is now operational behind the PALM-3000 extreme adaptive optics system and the Stellar Double Coronagraph at Palomar Observatory. Here we describe the motivation, design, and characterization of the instrument, early on-sky results, and future prospects.
△ Less
Submitted 16 April, 2018; v1 submitted 28 March, 2018;
originally announced March 2018.
-
Large-format platinum silicide microwave kinetic inductance detectors for optical to near-IR astronomy
Authors:
P. Szypryt,
S. R. Meeker,
G. Coiffard,
N. Fruitwala,
B. Bumble,
G. Ulbricht,
A. B. Walter,
M. Daal,
C. Bockstiegel,
G. Collura,
N. Zobrist,
I. Lipartito,
B. A. Mazin
Abstract:
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical…
▽ More
We have fabricated and characterized 10,000 and 20,440 pixel Microwave Kinetic Inductance Detector (MKID) arrays for the Dark-speckle Near-IR Energy-resolved Superconducting Spectrophotometer (DARKNESS) and the MKID Exoplanet Camera (MEC). These instruments are designed to sit behind adaptive optics systems with the goal of directly imaging exoplanets in a 800-1400 nm band. Previous large optical and near-IR MKID arrays were fabricated using substoichiometric titanium nitride (TiN) on a silicon substrate. These arrays, however, suffered from severe non-uniformities in the TiN critical temperature, causing resonances to shift away from their designed values and lowering usable detector yield. We have begun fabricating DARKNESS and MEC arrays using platinum silicide (PtSi) on sapphire instead of TiN. Not only do these arrays have much higher uniformity than the TiN arrays, resulting in higher pixel yields, they have demonstrated better spectral resolution than TiN MKIDs of similar design. PtSi MKIDs also do not display the hot pixel effects seen when illuminating TiN on silicon MKIDs with photons with wavelengths shorter than 1 um.
△ Less
Submitted 19 October, 2017;
originally announced October 2017.
-
High Quality Factor Platinum Silicide Microwave Kinetic Inductance Detectors
Authors:
P. Szypryt,
B. A. Mazin,
G. Ulbricht,
B. Bumble,
S. R. Meeker,
C. Bockstiegel,
A. B. Walter
Abstract:
We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nit…
▽ More
We report on the development of Microwave Kinetic Inductance Detectors (MKIDs) using platinum silicide as the sensor material. MKIDs are an emerging superconducting detector technology, capable of measuring the arrival times of single photons to better than two microseconds and their energies to around ten percent. Previously, MKIDs have been fabricated using either sub-stoichiometric titanium nitride or aluminum, but TiN suffers from spatial inhomogeneities in the superconducting critical temperature and Al has a low kinetic inductance fraction, causing low detector sensitivity. To address these issues, we have instead fabricated PtSi microresonators with superconducting critical temperatures of 944$\pm$12~mK and high internal quality factors ($Q_i \gtrsim 10^6$). These devices show typical quasiparticle lifetimes of $τ_{qp} \approx 30$--$40~μ$s and spectral resolution, $R = λ/ Δλ$, of 8 at 406.6~nm. We compare PtSi MKIDs to those fabricated with TiN and detail the substantial advantages that PtSi MKIDs have to offer.
△ Less
Submitted 3 October, 2016;
originally announced October 2016.
-
Search for Optical Pulsations in PSR J0337+1715
Authors:
M. J. Strader,
A. M. Archibald,
S. R. Meeker,
P. Szypryt,
A. B. Walter,
J. C. van Eyken,
G. Ulbricht,
C. Stoughton,
B. Bumble,
D. L. Kaplan,
B. A. Mazin
Abstract:
We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telesc…
▽ More
We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telescope at Palomar Observatory. No significant pulsations were found in the range 4000-11000 angstroms, and we can limit pulsed emission in g-band to be fainter than 25 mag.
△ Less
Submitted 16 March, 2016;
originally announced March 2016.
-
Highly Multiplexible Thermal Kinetic Inductance Detectors for X-Ray Imaging Spectroscopy
Authors:
Gerhard Ulbricht,
Benjamin A. Mazin,
Paul Szypryt,
Alex B. Walter,
Clint Bockstiegel,
Bruce Bumble
Abstract:
For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus pr…
▽ More
For X-ray imaging spectroscopy, high spatial resolution over a large field of view is often as important as high energy resolution, but current X-ray detectors do not provide both in the same device. Thermal Kinetic Inductance Detectors (TKIDs) are being developed as they offer a feasible way to combine the energy resolution of transition edge sensors with pixel counts approaching CCDs and thus promise significant improvements for many X-ray spectroscopy applications. TKIDs are a variation of Microwave Kinetic Inductance Detectors (MKIDs) and share their multiplexibility: working MKID arrays with 2024 pixels have recently been demonstrated and much bigger arrays are under development. In this work, we present our first working TKID prototypes which are able to achieve an energy resolution of 75 eV at 5.9 keV, even though their general design still has to be optimized. We further describe TKID fabrication, characterization, multiplexing and working principle and demonstrate the necessity of a data fitting algorithm in order to extract photon energies. With further design optimizations we expect to be able to improve our TKID energy resolution to less than 10 eV at 5.9 keV.
△ Less
Submitted 24 June, 2015;
originally announced June 2015.
-
Performance of the Caltech Submillimeter Observatory Dual-Color 180-720 GHz Balanced SIS Receivers
Authors:
J. W. Kooi,
R. A. Chamberlin,
R. Monje,
A. Kovacs,
F. Rice,
H. Yoshida,
B. Force,
K. Cooper,
D. Miller,
M. Gould,
D. Lis,
B. Bumble,
R. LeDuc,
J. A. Stern,
T. G. Phillips
Abstract:
We report on balanced SIS receivers covering the astronomical important 180-720 GHz submillimeter atmospheric window. To facilitate remote observations and automated spectral line surveys, fully synthesized local oscillators are employed. High-current-density Nb-AlN-Nb superconducting-insulating-superconducting (SIS) tunnel junctions are used as the mixing element. The measured double-sideband (DS…
▽ More
We report on balanced SIS receivers covering the astronomical important 180-720 GHz submillimeter atmospheric window. To facilitate remote observations and automated spectral line surveys, fully synthesized local oscillators are employed. High-current-density Nb-AlN-Nb superconducting-insulating-superconducting (SIS) tunnel junctions are used as the mixing element. The measured double-sideband (DSB) 230 GHz receiver noise temperature, uncorrected for optics loss, ranges from 50K at 185 GHz, 33K at 246 GHz, to 51K at 280 GHz. In this frequency range the mixer has a DSB conversion gain of 0 +- 1.5 dB. The measured 460 GHz double-sideband receiver noise temperature, uncorrected for optics loss, is 32K at 400 GHz, 34K at 460 GHz, and 61K at 520 GHz. Similar to the 230 GHz balanced mixer, the DSB mixer conversion gain is 1 +- 1 dB. To help optimize performance, the mixer IF circuits and bias injection are entirely planar by design. Dual-frequency observation, by means of separating the incoming circular polarized electric field into two orthogonal components, is another important mode of operation offered by the new facility instrumentation. Instrumental stability is excellent supporting the LO noise cancellation properties of the balanced mixer configuration. In the spring of 2012 the dual-frequency 230/460 SIS receiver was successfully installed at Caltech Submillimeter Observatory (CSO), Mauna Kea, HI.
△ Less
Submitted 5 February, 2014;
originally announced February 2014.
-
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Authors:
P. Szypryt,
G. E. Duggan,
B. A. Mazin,
S. R. Meeker,
M. J. Strader,
J. C. van Eyken,
D. Marsden,
K. O'Brien,
A. B. Walter,
G. Ulbricht,
T. A. Prince,
C. Stoughton,
B. Bumble
Abstract:
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" tele…
▽ More
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS, sensitive to radiation from 350 to 1100 nm, has a time resolution of several microseconds and can measure the energy of a photon to $\sim10%$. We present the light curves for these observations and examine changes in orbital period from prior observations. Using a quadratic ephemeris model, we measure a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use the high timing resolution of ARCONS to examine the system's high frequency variations and search for possible quasi-periodic oscillations (QPOs). Finally, we use the instrument's spectral resolution to examine the light curves in various wavelength bands. We do not find any high frequency QPOs or significant spectral variability throughout an eclipse.
△ Less
Submitted 16 September, 2013;
originally announced September 2013.
-
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant Pulses
Authors:
M. J. Strader,
M. D. Johnson,
B. A. Mazin,
G. V. Spiro Jaeger,
C. R. Gwinn,
S. R. Meeker,
P. Szypryt,
J. C. van Eyken,
D. Marsden,
K. O'Brien,
A. B. Walter,
G. Ulbricht,
C. Stoughton,
B. Bumble
Abstract:
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C.…
▽ More
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an $11.3\pm2.5\%$ increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.
△ Less
Submitted 8 November, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
Authors:
B. A. Mazin,
S. R. Meeker,
M. J. Strader,
B. Bumble,
K. O'Brien,
P. Szypryt,
D. Marsden,
J. C. van Eyken,
G. E. Duggan,
G. Ulbricht,
C. Stoughton,
M. Johnson
Abstract:
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without fi…
▽ More
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs are nearly ideal, noiseless photon detectors, as they do not suffer from read noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID array yielding a 20"x20" field of view, and has been deployed on the Palomar 200" and Lick 120" telescopes for 24 nights of observing. We present initial results showing that ARCONS and its MKID arrays are now a fully operational and powerful tool for astronomical observations.
△ Less
Submitted 19 June, 2013;
originally announced June 2013.
-
Position and energy-resolved particle detection using phonon-mediated microwave kinetic inductance detectors
Authors:
D. C. Moore,
S. R. Golwala,
B. Bumble,
B. Cornell,
P. K. Day,
H. G. LeDuc,
J. Zmuidzinas
Abstract:
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations…
▽ More
We demonstrate position and energy-resolved phonon-mediated detection of particle interactions in a silicon substrate instrumented with an array of microwave kinetic inductance detectors (MKIDs). The relative magnitude and delay of the signal received in each sensor allows the location of the interaction to be determined with < 1 mm precision at 30 keV. Using this position information, variations in the detector response with position can be removed, and an energy resolution of σ_E = 0.55 keV at 30 keV was measured. Since MKIDs can be fabricated from a single deposited film and are naturally multiplexed in the frequency domain, this technology can be extended to provide highly-pixelized athermal phonon sensors for ~1 kg scale detector elements. Such high-resolution, massive particle detectors would be applicable to next-generation rare-event searches such as the direct detection of dark matter, neutrinoless double-beta decay, or coherent neutrino-nucleus scattering.
△ Less
Submitted 10 June, 2012; v1 submitted 20 March, 2012;
originally announced March 2012.
-
ARCONS: a highly multiplexed superconducting UV to near-IR camera
Authors:
Kieran O'Brien,
Benjamin A. Mazin,
Sean McHugh,
Seth Meeker,
Bruce Bumble
Abstract:
ARCONS, the Array Camera for Optical to Near-infrared Spectrophotometry, was recently commissioned at the Coude focus of the 200-inch Hale Telescope at the Palomar Observatory. At the heart of this unique instrument is a 1024-pixel Microwave Kinetic Inductance Detector (MKID), exploiting the Kinetic Inductance effect to measure the energy of the incoming photon to better than several percent. The…
▽ More
ARCONS, the Array Camera for Optical to Near-infrared Spectrophotometry, was recently commissioned at the Coude focus of the 200-inch Hale Telescope at the Palomar Observatory. At the heart of this unique instrument is a 1024-pixel Microwave Kinetic Inductance Detector (MKID), exploiting the Kinetic Inductance effect to measure the energy of the incoming photon to better than several percent. The ground-breaking instrument is lens-coupled with a pixel scale of 0.23"/pixel, with each pixel recording the arrival time (<2 microsec) and energy of a photon (~10%) in the optical to near-IR (0.4-1.1 microns) range. The scientific objectives of the instrument include the rapid follow-up and classification of the transient phenomena.
△ Less
Submitted 27 January, 2012;
originally announced January 2012.
-
A superconducting focal plane array for ultraviolet, optical, and near-infrared astrophysics
Authors:
Benjamin A. Mazin,
Bruce Bumble,
Seth R. Meeker,
Kieran O'Brien,
Sean McHugh,
Eric Langman
Abstract:
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a photon-variable superconducting inductance in a lithographed microresonator, and is capable of functioning as a photon detector across the electromagnetic spectr…
▽ More
Microwave Kinetic Inductance Detectors, or MKIDs, have proven to be a powerful cryogenic detector technology due to their sensitivity and the ease with which they can be multiplexed into large arrays. A MKID is an energy sensor based on a photon-variable superconducting inductance in a lithographed microresonator, and is capable of functioning as a photon detector across the electromagnetic spectrum as well as a particle detector. Here we describe the first successful effort to create a photon-counting, energy-resolving ultraviolet, optical, and near infrared MKID focal plane array. These new Optical Lumped Element (OLE) MKID arrays have significant advantages over semiconductor detectors like charge coupled devices (CCDs). They can count individual photons with essentially no false counts and determine the energy and arrival time of every photon with good quantum efficiency. Their physical pixel size and maximum count rate is well matched with large telescopes. These capabilities enable powerful new astrophysical instruments usable from the ground and space. MKIDs could eventually supplant semiconductor detectors for most astronomical instrumentation, and will be useful for other disciplines such as quantum optics and biological imaging.
△ Less
Submitted 30 November, 2011;
originally announced December 2011.
-
Herschel observations of EXtra-Ordinary Sources: The Terahertz spectrum of Orion KL seen at high spectral resolution
Authors:
N. R. Crockett,
E. A. Bergin,
S. Wang,
D. C. Lis,
T. A. Bell,
G. A. Blake,
A. Boogert,
B. Bumble,
S. Cabrit,
E. Caux,
C. Ceccarelli,
J. Cernicharo,
C. Comito,
F. Daniel,
M. -L. Dubernet,
M. Emprechtinger,
P. Encrenaz,
E. Falgarone,
M. Gerin,
T. F. Giesen,
J. R. Goicoechea,
P. F. Goldsmith,
H. Gupta,
R. Gusten,
P. Hartogh
, et al. (38 additional authors not shown)
Abstract:
We present the first high spectral resolution observations of Orion KL in the frequency ranges 1573.4 - 1702.8 GHz (band 6b) and 1788.4 - 1906.8 GHz (band 7b) obtained using the HIFI instrument on board the Herschel Space Observatory. We characterize the main emission lines found in the spectrum, which primarily arise from a range of components associated with Orion KL including the hot core, but…
▽ More
We present the first high spectral resolution observations of Orion KL in the frequency ranges 1573.4 - 1702.8 GHz (band 6b) and 1788.4 - 1906.8 GHz (band 7b) obtained using the HIFI instrument on board the Herschel Space Observatory. We characterize the main emission lines found in the spectrum, which primarily arise from a range of components associated with Orion KL including the hot core, but also see widespread emission from components associated with molecular outflows traced by H2O, SO2, and OH. We find that the density of observed emission lines is significantly diminished in these bands compared to lower frequency Herschel/HIFI bands.
△ Less
Submitted 26 July, 2010;
originally announced July 2010.
-
Herschel observations of EXtra-Ordinary Sources: the present and future of spectral surveys with Herschel/HIFI
Authors:
E. A. Bergin,
T. G. Phillips,
C. Comito,
N. R. Crockett,
D. C. Lis,
P. Schilke,
S. Wang,
T. A. Bell,
G. A. Blake,
B. Bumble,
E. Caux,
S. Cabrit,
C. Ceccarelli,
J. Cernicharo,
F. Daniel,
Th. de Graauw,
M. -L. Dubernet,
M. Emprechtinger,
P. Encrenaz,
E. Falgarone,
M. Gerin,
T. F. Giesen,
J. R. Goicoechea,
P. F. Goldsmith,
H. Gupta
, et al. (34 additional authors not shown)
Abstract:
We present initial results from the Herschel GT key program: Herschel observations of EXtra-Ordinary Sources (HEXOS) and outline the promise and potential of spectral surveys with Herschel/HIFI. The HIFI instrument offers unprecedented sensitivity, as well as continuous spectral coverage across the gaps imposed by the atmosphere, opening up a largely unexplored wavelength regime to high-resolution…
▽ More
We present initial results from the Herschel GT key program: Herschel observations of EXtra-Ordinary Sources (HEXOS) and outline the promise and potential of spectral surveys with Herschel/HIFI. The HIFI instrument offers unprecedented sensitivity, as well as continuous spectral coverage across the gaps imposed by the atmosphere, opening up a largely unexplored wavelength regime to high-resolution spectroscopy. We show the spectrum of Orion KL between 480 and 560 GHz and from 1.06 to 1.115 THz. From these data, we confirm that HIFI separately measures the dust continuum and spectrally resolves emission lines in Orion KL. Based on this capability we demonstrate that the line contribution to the broad-band continuum in this molecule-rich source is ~20-40% below 1 THz and declines to a few percent at higher frequencies. We also tentatively identify multiple transitions of HD18O in the spectra. The first detection of this rare isotopologue in the interstellar medium suggests that HDO emission is optically thick in the Orion hot core with HDO/H2O ~ 0.02. We discuss the implications of this detection for the water D/H ratio in hot cores.
△ Less
Submitted 13 July, 2010;
originally announced July 2010.
-
ARCONS: A highly multiplexed superconducting optical to near-IR camera
Authors:
Benjamin A. Mazin,
Kieran O'Brien,
Sean McHugh,
Bruce Bumble,
David Moore,
Sunil Golwala,
Jonas Zmuidzinas
Abstract:
We report on the development of ARCONS, the ARray Camera for Optical to Near-IR Spectrophotometry. This photon counting integral field unit (IFU), being built at UCSB and Caltech with detectors fabricated at JPL, will use a unique, highly multiplexed low temperature detector technology known as Microwave Kinetic Inductance Detectors (MKIDs). These detectors, which operate at 100 mK, should provide…
▽ More
We report on the development of ARCONS, the ARray Camera for Optical to Near-IR Spectrophotometry. This photon counting integral field unit (IFU), being built at UCSB and Caltech with detectors fabricated at JPL, will use a unique, highly multiplexed low temperature detector technology known as Microwave Kinetic Inductance Detectors (MKIDs). These detectors, which operate at 100 mK, should provide photon counting with energy resolution of R = E/δE > 20 and time resolution of a microsecond, with a quantum efficiency of around 50%. We expect to field the instrument at the Palomar 200" telescope in the first quarter of 2011 with an array containing 1024 pixels in a 32x32 pixel form factor to yield a field of view of approximately 10x10 arcseconds. The bandwidth of the camera is limited by the rising sky count rate at longer wavelengths, but we anticipate a bandwidth of 0.35 to 1.35 μm will be achievable. A simple optical path and compact dewar utilizing a cryogen-free adiabatic demagnetization refridgerator (ADR) allows the camera to be deployed quickly at Naysmith or Coude foci at a variety of telescopes. A highly expandable software defined radio (SDR) readout that can scale up to much larger arrays has been developed.
△ Less
Submitted 5 July, 2010;
originally announced July 2010.
-
HIFI observations of warm gas in DR21: Shock versus radiative heating
Authors:
V. Ossenkopf,
M. Röllig,
R. Simon,
N. Schneider,
Y. Okada,
J. Stutzki,
M. Gerin,
M. Akyilmaz,
D. Beintema,
A. O. Benz,
O. Berne,
F. Boulanger,
B. Bumble,
O. Coeur-Joly,
C. Dedes,
M. C. Diez-Gonzalez,
K. France,
A. Fuente,
J. D. Gallego,
J. R. Goicoechea,
R. Güsten,
A. Harris,
R. Higgins,
B. Jackson,
C. Jarchow
, et al. (13 additional authors not shown)
Abstract:
The molecular gas in the DR21 massive star formation region is known to be affected by the strong UV field from the central star cluster and by a fast outflow creating a bright shock. The relative contribution of both heating mechanisms is the matter of a long debate. By better sampling the excitation ladder of various tracers we provide a quantitative distinction between the different heating mec…
▽ More
The molecular gas in the DR21 massive star formation region is known to be affected by the strong UV field from the central star cluster and by a fast outflow creating a bright shock. The relative contribution of both heating mechanisms is the matter of a long debate. By better sampling the excitation ladder of various tracers we provide a quantitative distinction between the different heating mechanisms. HIFI observations of mid-J transitions of CO and HCO+ isotopes allow us to bridge the gap in excitation energies between observations from the ground, characterizing the cooler gas, and existing ISO LWS spectra, constraining the properties of the hot gas. Comparing the detailed line profiles allows to identify the physical structure of the different components. In spite of the known shock-excitation of H2 and the clearly visible strong outflow, we find that the emission of all lines up to > 2 THz can be explained by purely radiative heating of the material. However, the new Herschel/HIFI observations reveal two types of excitation conditions. We find hot and dense clumps close to the central cluster, probably dynamically affected by the outflow, and a more widespread distribution of cooler, but nevertheless dense, molecular clumps.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
A Position Sensitive X-ray Spectrophotometer using Microwave Kinetic Inductance Detectors
Authors:
Benjamin A. Mazin,
Megan E. Eckart,
Bruce Bumble,
Sunil Golwala,
Peter K. Day,
Jonas Zmuidzinas,
Fiona A. Harrison
Abstract:
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon e…
▽ More
The surface impedance of a superconductor changes when energy is absorbed and Cooper pairs are broken to produce single electron (quasiparticle) excitations. This change may be sensitively measured using a thin-film resonant circuit called a microwave kinetic inductance detector (MKID). The practical application of MKIDs for photon detection requires a method of efficiently coupling the photon energy to the MKID. We present results on position sensitive X-ray detectors made by using two aluminum MKIDs on either side of a tantalum photon absorber strip. Diffusion constants, recombination times, and energy resolution are reported. MKIDs can easily be scaled into large arrays.
△ Less
Submitted 4 October, 2006;
originally announced October 2006.