DESHIMA on ASTE: On-sky Responsivity Calibration of the Integrated Superconducting Spectrometer
Authors:
Tatsuya Takekoshi,
Kenichi Karatsu,
Junya Suzuki,
Yoichi Tamura,
Tai Oshima,
Akio Taniguchi,
Shin'ichiro Asayama,
Tom J. L. C. Bakx,
Jochem J. A. Baselmans,
Sjoerd Bosma,
Juan Bueno,
Kah Wuy Chin,
Yasunori Fujii,
Kazuyuki Fujita,
Robert Huiting,
Soh Ikarashi,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Teun M. Klapwijk,
Kotaro Kohno,
Akira Kouchi,
Nuria Llombart,
Jun Maekawa,
Vignesh Murugesan
, et al. (14 additional authors not shown)
Abstract:
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope.…
▽ More
We are developing an ultra-wideband spectroscopic instrument, DESHIMA (DEep Spectroscopic HIgh-redshift MApper), based on the technologies of an on-chip filter-bank and Microwave Kinetic Inductance Detector (MKID) to investigate dusty star-burst galaxies in the distant universe at millimeter and submillimeter wavelength. An on-site experiment of DESHIMA was performed using the ASTE 10-m telescope. We established a responsivity model that converts frequency responses of the MKIDs to line-of-sight brightness temperature. We estimated two parameters of the responsivity model using a set of skydip data taken under various precipitable water vapor (PWV, 0.4-3.0 mm) conditions for each MKID. The line-of-sight brightness temperature of sky is estimated using an atmospheric transmission model and the PWVs. As a result, we obtain an average temperature calibration uncertainty of $1σ=4$%, which is smaller than other photometric biases. In addition, the average forward efficiency of 0.88 in our responsivity model is consistent with the value expected from the geometrical support structure of the telescope. We also estimate line-of-sight PWVs of each skydip observation using the frequency response of MKIDs, and confirm the consistency with PWVs reported by the Atacama Large Millimeter/submillimeter Array.
△ Less
Submitted 15 January, 2020;
originally announced January 2020.
-
First light demonstration of the integrated superconducting spectrometer
Authors:
Akira Endo,
Kenichi Karatsu,
Yoichi Tamura,
Tai Oshima,
Akio Taniguchi,
Tatsuya Takekoshi,
Shin'ichiro Asayama,
Tom J. L. C. Bakx,
Sjoerd Bosma,
Juan Bueno,
Kah Wuy Chin,
Yasunori Fujii,
Kazuyuki Fujita,
Robert Huiting,
Soh Ikarashi,
Tsuyoshi Ishida,
Shun Ishii,
Ryohei Kawabe,
Teun M. Klapwijk,
Kotaro Kohno,
Akira Kouchi,
Nuria Llombart,
Jun Maekawa,
Vignesh Murugesan,
Shunichi Nakatsubo
, et al. (14 additional authors not shown)
Abstract:
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pix…
▽ More
Ultra-wideband 3D imaging spectrometry in the millimeter-submillimeter (mm-submm) band is an essential tool for uncovering the dust-enshrouded portion of the cosmic history of star formation and galaxy evolution. However, it is challenging to scale up conventional coherent heterodyne receivers or free-space diffraction techniques to sufficient bandwidths ($\geq$1 octave) and numbers of spatial pixels (>$10^2$). Here we present the design and first astronomical spectra of an intrinsically scalable, integrated superconducting spectrometer, which covers 332-377 GHz with a spectral resolution of $F/ΔF \sim 380$. It combines the multiplexing advantage of microwave kinetic inductance detectors (MKIDs) with planar superconducting filters for dispersing the signal in a single, small superconducting integrated circuit. We demonstrate the two key applications for an instrument of this type: as an efficient redshift machine, and as a fast multi-line spectral mapper of extended areas. The line detection sensitivity is in excellent agreement with the instrument design and laboratory performance, reaching the atmospheric foreground photon noise limit on sky. The design can be scaled to bandwidths in excess of an octave, spectral resolution up to a few thousand and frequencies up to $\sim$1.1 THz. The miniature chip footprint of a few $\mathrm{cm^2}$ allows for compact multi-pixel spectral imagers, which would enable spectroscopic direct imaging and large volume spectroscopic surveys that are several orders of magnitude faster than what is currently possible.
△ Less
Submitted 18 September, 2019; v1 submitted 24 June, 2019;
originally announced June 2019.
-
Wideband on-chip terahertz spectrometer based on a superconducting filterbank
Authors:
Akira Endo,
Kenichi Karatsu,
Alejandro Pascual Laguna,
Behnam Mirzaei,
Robert Huiting,
David J. Thoen,
Vignesh Murugesan,
Stephen J. C. Yates,
Juan Bueno,
Nuri van Marrewijk,
Sjoerd Bosma,
Ozan Yurduseven,
Nuria Llombart,
Junya Suzuki,
Masato Naruse,
Pieter J. de Visser,
Paul P. van der Werf,
Teun M. Klapwijk,
Jochem J. A. Baselmans
Abstract:
Terahertz spectrometers with a wide instantaneous frequency coverage for passive remote sensing are enormously attractive for many terahertz applications, such as astronomy, atmospheric science and security. Here we demonstrate a wide-band terahertz spectrometer based on a single superconducting chip. The chip consists of an antenna coupled to a transmission line filterbank, with a microwave kinet…
▽ More
Terahertz spectrometers with a wide instantaneous frequency coverage for passive remote sensing are enormously attractive for many terahertz applications, such as astronomy, atmospheric science and security. Here we demonstrate a wide-band terahertz spectrometer based on a single superconducting chip. The chip consists of an antenna coupled to a transmission line filterbank, with a microwave kinetic inductance detector behind each filter. Using frequency division multiplexing, all detectors are read-out simultaneously creating a wide-band spectrometer with an instantaneous bandwidth of 45 GHz centered around 350 GHz. The spectrometer has a spectral resolution of $F/ΔF=380$ and reaches photon-noise limited sensitivity. We discuss the chip design and fabrication, as well as the system integration and testing. We confirm full system operation by the detection of an emission line spectrum of methanol gas. The proposed concept allows for spectroscopic radiation detection over large bandwidths and resolutions up to $F/ΔF\sim1000$, all using a chip area of a few $\mathrm{cm^2}$. This will allow the construction of medium resolution imaging spectrometers with unprecedented speed and sensitivity.
△ Less
Submitted 21 June, 2019; v1 submitted 21 January, 2019;