-
The LOFT Ground Segment
Authors:
E. Bozzo,
A. Antonelli,
A. Argan,
D. Barret,
P. Binko,
S. Brandt,
E. Cavazzuti,
T. Courvoisier,
J. W. den Herder,
M. Feroci,
C. Ferrigno,
P. Giommi,
D. Götz,
L. Guy,
M. Hernanz,
J. J. M. in't Zand,
D. Klochkov,
E. Kuulkers,
C. Motch,
D. Lumb,
A. Papitto,
C. Pittori,
R. Rohlfs,
A. Santangelo,
C. Schmid
, et al. (5 additional authors not shown)
Abstract:
LOFT, the Large Observatory For X-ray Timing, was one of the ESA M3 mission candidates that completed their assessment phase at the end of 2013. LOFT is equipped with two instruments, the Large Area Detector (LAD) and the Wide Field Monitor (WFM). The LAD performs pointed observations of several targets per orbit (~90 minutes), providing roughly ~80 GB of proprietary data per day (the proprietary…
▽ More
LOFT, the Large Observatory For X-ray Timing, was one of the ESA M3 mission candidates that completed their assessment phase at the end of 2013. LOFT is equipped with two instruments, the Large Area Detector (LAD) and the Wide Field Monitor (WFM). The LAD performs pointed observations of several targets per orbit (~90 minutes), providing roughly ~80 GB of proprietary data per day (the proprietary period will be 12 months). The WFM continuously monitors about 1/3 of the sky at a time and provides data for about ~100 sources a day, resulting in a total of ~20 GB of additional telemetry. The LOFT Burst alert System additionally identifies on-board bright impulsive events (e.g., Gamma-ray Bursts, GRBs) and broadcasts the corresponding position and trigger time to the ground using a dedicated system of ~15 VHF receivers. All WFM data are planned to be made public immediately. In this contribution we summarize the planned organization of the LOFT ground segment (GS), as established in the mission Yellow Book 1 . We describe the expected GS contributions from ESA and the LOFT consortium. A review is provided of the planned LOFT data products and the details of the data flow, archiving and distribution. Despite LOFT was not selected for launch within the M3 call, its long assessment phase (> 2 years) led to a very solid mission design and an efficient planning of its ground operations.
△ Less
Submitted 27 August, 2014;
originally announced August 2014.
-
The Large Observatory For x-ray Timing
Authors:
M. Feroci,
J. W. den Herder,
E. Bozzo,
D. Barret,
S. Brandt,
M. Hernanz,
M. van der Klis,
M. Pohl,
A. Santangelo,
L. Stella,
A. Watts,
J. Wilms,
S. Zane,
M. Ahangarianabhari,
C. Albertus,
M. Alford,
A. Alpar,
D. Altamirano,
L. Alvarez,
L. Amati,
C. Amoros,
N. Andersson,
A. Antonelli,
A. Argan,
R. Artigue
, et al. (320 additional authors not shown)
Abstract:
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost…
▽ More
The Large Observatory For x-ray Timing (LOFT) was studied within ESA M3 Cosmic Vision framework and participated in the final down-selection for a launch slot in 2022-2024. Thanks to the unprecedented combination of effective area and spectral resolution of its main instrument, LOFT will study the behaviour of matter under extreme conditions, such as the strong gravitational field in the innermost regions of accretion flows close to black holes and neutron stars, and the supra-nuclear densities in the interior of neutron stars. The science payload is based on a Large Area Detector (LAD, 10 m 2 effective area, 2-30 keV, 240 eV spectral resolution, 1 deg collimated field of view) and a WideField Monitor (WFM, 2-50 keV, 4 steradian field of view, 1 arcmin source location accuracy, 300 eV spectral resolution). The WFM is equipped with an on-board system for bright events (e.g. GRB) localization. The trigger time and position of these events are broadcast to the ground within 30 s from discovery. In this paper we present the status of the mission at the end of its Phase A study.
△ Less
Submitted 29 August, 2014; v1 submitted 27 August, 2014;
originally announced August 2014.
-
Planck Early Results. V. The Low Frequency Instrument data processing
Authors:
A. Zacchei,
D. Maino,
C. Baccigalupi,
M. Bersanelli,
A. Bonaldi,
L. Bonavera,
C. Burigana,
R. C. Butler,
F. Cuttaia,
G. de Zotti,
J. Dick,
M. Frailis,
S. Galeotta,
J. González-Nuevo,
K. M. Górski,
A. Gregorio,
E. Keihänen,
R. Keskitalo,
J. Knoche,
H. Kurki-Suonio,
C. R. Lawrence,
S. Leach,
J. P. Leahy,
M. López-Caniego,
N. Mandolesi
, et al. (124 additional authors not shown)
Abstract:
We describe the processing of data from the Low Frequency Instrument (LFI) used in production of the Planck Early Release Compact Source Catalogue (ERCSC). In particular, we discuss the steps involved in reducing the data from telemetry packets to cleaned, calibrated, time-ordered data (TOD) and frequency maps. Data are continuously calibrated using the modulation of the temperature of the cosmic…
▽ More
We describe the processing of data from the Low Frequency Instrument (LFI) used in production of the Planck Early Release Compact Source Catalogue (ERCSC). In particular, we discuss the steps involved in reducing the data from telemetry packets to cleaned, calibrated, time-ordered data (TOD) and frequency maps. Data are continuously calibrated using the modulation of the temperature of the cosmic microwave background radiation induced by the motion of the spacecraft. Noise properties are estimated from TOD from which the sky signal has been removed using a generalized least square map-making algorithm. Measured 1/f noise knee-frequencies range from 100mHz at 30GHz to a few tens of mHz at 70GHz. A destriping code (Madam) is employed to combine radiometric data and pointing information into sky maps, minimizing the variance of correlated noise. Noise covariance matrices required to compute statistical uncertainties on LFI and Planck products are also produced. Main beams are estimated down to the approx -10dB level using Jupiter transits, which are also used for geometrical calibration of the focal plane.
△ Less
Submitted 7 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
A systematic approach to the Planck LFI end-to-end test and its application to the DPC Level 1 pipeline
Authors:
M. Frailis,
M. Maris,
A. Zacchei,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
S. R. Lowe,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
F. Pasian,
F. Perrotta,
M. Sandri,
L. Terenzi,
M. Tomasi
, et al. (1 additional authors not shown)
Abstract:
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekeeping telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and…
▽ More
The Level 1 of the Planck LFI Data Processing Centre (DPC) is devoted to the handling of the scientific and housekeeping telemetry. It is a critical component of the Planck ground segment which has to strictly commit to the project schedule to be ready for the launch and flight operations. In order to guarantee the quality necessary to achieve the objectives of the Planck mission, the design and development of the Level 1 software has followed the ESA Software Engineering Standards. A fundamental step in the software life cycle is the Verification and Validation of the software. The purpose of this work is to show an example of procedures, test development and analysis successfully applied to a key software project of an ESA mission. We present the end-to-end validation tests performed on the Level 1 of the LFI-DPC, by detailing the methods used and the results obtained. Different approaches have been used to test the scientific and housekeeping data processing. Scientific data processing has been tested by injecting signals with known properties directly into the acquisition electronics, in order to generate a test dataset of real telemetry data and reproduce as much as possible nominal conditions. For the HK telemetry processing, validation software have been developed to inject known parameter values into a set of real housekeeping packets and perform a comparison with the corresponding timelines generated by the Level 1. With the proposed validation and verification procedure, where the on-board and ground processing are viewed as a single pipeline, we demonstrated that the scientific and housekeeping processing of the Planck-LFI raw data is correct and meets the project requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
LFI Radiometric Chain Assembly (RCA) data handling "Rachel"
Authors:
M. Malaspina,
E. Franceschi,
P. Battaglia,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
C. Franceschet,
S. Galeotta,
F. Gasparo,
A. Gregorio,
M. Lapolla,
R. Leonardi,
G. Maggio,
N. Mandolesi,
P. Manzato,
M. Maris,
M. Meharga,
P. Meinhold,
N. Morisset,
F. Pasian,
F. Perrotta,
R. Rohlfs,
M. Sandri
, et al. (4 additional authors not shown)
Abstract:
This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiomete…
▽ More
This paper is part of the Prelaunch status LFI papers published on JINST (http://www.iop.org/EJ/journal/-page=extra.proc5/1748-0221).
Planck's Low Frequency Instrument is an array of 22 pseudo-correlation radiometers at 30, 44, and 70 GHz. Before integrating the overall array assembly, a first set of tests has been performed for each radiometer chain assembly (RCA), consisting of two radiometers. In this paper, we describe Rachel, a software application which has been purposely developed and used during the RCA test campaign to carry out both near-realtime on-line data analysis and data storage (in FITS format) of the raw output from the radiometric chains.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Optimization of Planck/LFI on--board data handling
Authors:
M. Maris,
M. Tomasi,
S. Galeotta,
M. Miccolis,
S. Hildebrandt,
M. Frailis,
R. Rohlfs,
N. Morisset,
A. Zacchei,
M. Bersanelli,
P. Binko,
C. Burigana,
R. C. Butler,
F. Cuttaia,
H. Chulani,
O. D'Arcangelo,
S. Fogliani,
E. Franceschi,
F. Gasparo,
F. Gomez,
A. Gregorio,
J. M. Herreros,
R. Leonardi,
P. Leutenegger,
G. Maggio
, et al. (12 additional authors not shown)
Abstract:
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy…
▽ More
To asses stability against 1/f noise, the Low Frequency Instrument (LFI) onboard the Planck mission will acquire data at a rate much higher than the data rate allowed by its telemetry bandwith of 35.5 kbps. The data are processed by an onboard pipeline, followed onground by a reversing step. This paper illustrates the LFI scientific onboard processing to fit the allowed datarate. This is a lossy process tuned by using a set of 5 parameters Naver, r1, r2, q, O for each of the 44 LFI detectors. The paper quantifies the level of distortion introduced by the onboard processing, EpsilonQ, as a function of these parameters. It describes the method of optimizing the onboard processing chain. The tuning procedure is based on a optimization algorithm applied to unprocessed and uncompressed raw data provided either by simulations, prelaunch tests or data taken from LFI operating in diagnostic mode. All the needed optimization steps are performed by an automated tool, OCA2, which ends with optimized parameters and produces a set of statistical indicators, among them the compression rate Cr and EpsilonQ. For Planck/LFI the requirements are Cr = 2.4 and EpsilonQ <= 10% of the rms of the instrumental white noise. To speedup the process an analytical model is developed that is able to extract most of the relevant information on EpsilonQ and Cr as a function of the signal statistics and the processing parameters. This model will be of interest for the instrument data analysis. The method was applied during ground tests when the instrument was operating in conditions representative of flight. Optimized parameters were obtained and the performance has been verified, the required data rate of 35.5 Kbps has been achieved while keeping EpsilonQ at a level of 3.8% of white noise rms well within the requirements.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Level 1 on-ground telemetry handling in Planck LFI
Authors:
A. Zacchei,
M. Frailis,
M. Maris,
N. Morisset,
R. Rohlfs,
M. Meharga,
P. Binko,
M. Turler,
S. Galeotta,
F. Gasparo,
E. Franceschi,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
S. Fogliani,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
D. Maino,
G. Maggio,
M. Malaspina,
N. Mandolesi,
P. Manzato,
P. Meinhold,
L. Mendes
, et al. (9 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeepin…
▽ More
The Planck Low Frequency Instrument (LFI) will observe the Cosmic Microwave Background (CMB) by covering the frequency range 30-70 GHz in three bands. The primary instrument data source are the temperature samples acquired by the 22 radiometers mounted on the Planck focal plane. Such samples represent the scientific data of LFI. In addition, the LFI instrument generates the so called housekeeping data by sampling regularly the on-board sensors and registers. The housekeeping data provides information on the overall health status of the instrument and on the scientific data quality. The scientific and housekeeping data are collected on-board into telemetry packets compliant with the ESA Packet Telemetry standards. They represent the primary input to the first processing level of the LFI Data Processing Centre. In this work we show the software systems which build the LFI Level 1. A real-time assessment system, based on the ESA SCOS 2000 generic mission control system, has the main purpose of monitoring the housekeeping parameters of LFI and detect possible anomalies. A telemetry handler system processes the housekeeping and scientific telemetry of LFI, generating timelines for each acquisition chain and each housekeeping parameter. Such timelines represent the main input to the subsequent processing levels of the LFI DPC. A telemetry quick-look system allows the real-time visualization of the LFI scientific and housekeeping data, by also calculating quick statistical functions and fast Fourier transforms. The LFI Level 1 has been designed to support all the mission phases, from the instrument ground tests and calibration to the flight operations, and developed according to the ESA engineering standards.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Off-line radiometric analysis of Planck/LFI data
Authors:
M. Tomasi,
A. Mennella,
S. Galeotta,
S. R. Lowe,
L. Mendes,
R. Leonardi,
F. Villa,
B. Cappellini,
A. Gregorio,
P. Meinhold,
M. Sandri,
F. Cuttaia,
L. Terenzi,
M. Maris,
L. Valenziano,
M. J. Salmon,
M. Bersanelli,
P. Binko,
R. C. Butler,
O. D'Arcangelo,
S. Fogliani,
M. Frailis,
E. Franceschi,
F. Gasparo,
G. Maggio
, et al. (13 additional authors not shown)
Abstract:
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common pla…
▽ More
The Planck Low Frequency Instrument (LFI) is an array of 22 pseudo-correlation radiometers on-board the Planck satellite to measure temperature and polarization anisotropies in the Cosmic Microwave Background (CMB) in three frequency bands (30, 44 and 70 GHz). To calibrate and verify the performances of the LFI, a software suite named LIFE has been developed. Its aims are to provide a common platform to use for analyzing the results of the tests performed on the single components of the instrument (RCAs, Radiometric Chain Assemblies) and on the integrated Radiometric Array Assembly (RAA). Moreover, its analysis tools are designed to be used during the flight as well to produce periodic reports on the status of the instrument. The LIFE suite has been developed using a multi-layered, cross-platform approach. It implements a number of analysis modules written in RSI IDL, each accessing the data through a portable and heavily optimized library of functions written in C and C++. One of the most important features of LIFE is its ability to run the same data analysis codes both using ground test data and real flight data as input. The LIFE software suite has been successfully used during the RCA/RAA tests and the Planck Integrated System Tests. Moreover, the software has also passed the verification for its in-flight use during the System Operations Verification Tests, held in October 2008.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.