-
Limitations to the energy resolution of single-photon sensitive Microwave Kinetic Inductance Detectors
Authors:
Mario De Lucia,
Gerhard Ulbricht,
Eoin Baldwin,
Jack Piercy,
Colm Bracken,
Oisin Creaner,
Tom Ray
Abstract:
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier no…
▽ More
This paper describes the energy resolution of Microwave Kinetic Inductance Detectors (MKIDs), and models some limiting factors to it. Energy resolution is a measure of the smallest possible difference in energy of the impinging photons, Delta E, that the detector can identify and is of critical importance for many applications. Limits to the energy resolution cause by the Fano effect, amplifier noise, current inhomogeneities, and readout sampling frequency are taken into consideration for this model. This paper describes an approach to combine all of these limitations and predict a wavelength dependency of the upper limit to the resolving power.
△ Less
Submitted 15 February, 2024;
originally announced February 2024.
-
Frequency Domain Multiplexing for MKIDs: Comparing the Xilinx ZCU111 RFSoC with their new 2x2 RFSoC board
Authors:
Eoin Baldwin,
Mario De Lucia,
Colm Bracken,
Gerhard Ulbricht,
Oisin Creaner,
Jack Piercy,
Tom Ray
Abstract:
The Xilinx ZCU111 Radio Frequency System on Chip (RFSoC) is a promising solution for reading out large arrays of microwave kinetic inductance detectors (MKIDs). The board boasts eight on-chip 12-bit / 4.096 GSPS analogue-to-digital converters (ADCs) and eight 14-bit / 6.554 GSPS digital-to-analogue converters (DACs), as well as field programmable gate array (FPGA) resources of 930,000 logic cells…
▽ More
The Xilinx ZCU111 Radio Frequency System on Chip (RFSoC) is a promising solution for reading out large arrays of microwave kinetic inductance detectors (MKIDs). The board boasts eight on-chip 12-bit / 4.096 GSPS analogue-to-digital converters (ADCs) and eight 14-bit / 6.554 GSPS digital-to-analogue converters (DACs), as well as field programmable gate array (FPGA) resources of 930,000 logic cells and 4,272 digital signal processing (DSP) slices. While this is sufficient data converter bandwidth for the readout of 8,000 MKIDs, with a 2 MHz channel-spacing, and a 1 MHz sampling rate (per channel), additional FPGA resources are needed to perform the DSP needed to process this large number of MKIDs. A solution to this problem is the new Xilinx RFSoC 2x2 board. This board costs only one fifth of the ZCU111 while still providing the same logic resources as the ZCU111, albeit with only a quarter of the data converter resources. Thus, using multiple RFSoC 2x2 boards would provide a better balance between FPGA resources and data converters, allowing the full utilization of the RF bandwidth provided by the data converters, while also lowering the cost per pixel value of the readout system, from approximately EUR2.50 per pixel with the ZCU111, to EUR1 per pixel.
△ Less
Submitted 23 January, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
High-uniformity TiN/Ti/TiN multilayers for the development of Microwave Kinetic Inductance Detector
Authors:
Mario De Lucia,
E. Baldwin,
G. Ulbricht,
J. D. Piercy,
O. Creaner,
C. Bracken,
T. P. Ray
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are a class of superconducting cryogenic detectors that simultaneously exhibit energy resolution, time resolution and spatial resolution. The pixel yield of MKID arrays is usually a critical figure of merit in the characterisation of an MKIDs array. Currently, for MKIDs intended for the detection of optical and near-infrared photons, only the best arr…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are a class of superconducting cryogenic detectors that simultaneously exhibit energy resolution, time resolution and spatial resolution. The pixel yield of MKID arrays is usually a critical figure of merit in the characterisation of an MKIDs array. Currently, for MKIDs intended for the detection of optical and near-infrared photons, only the best arrays exhibit a pixel yield as high as 75-80%. The uniformity of the superconducting film used for the fabrication of MKIDs arrays is often regarded as the main limiting factor to the pixel yield of an array. In this paper we will present data on the uniformity of the TiN/Ti/TiN multilayers deposited at the Tyndall National Institute and compare these results with a statistical model that evaluates how inhomogeneities affect the pixel yield of an array.
△ Less
Submitted 19 January, 2023; v1 submitted 18 January, 2023;
originally announced January 2023.
-
Repurposing ROACH-1 boards for prototyping of readout systems for optical-NIR MKIDs
Authors:
Oisín Creaner,
Colm Bracken,
Jack Piercy,
Gerhard Ulbricht,
Eoin Baldwin,
Mario De Lucia,
Tom Ray
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are cryogenic photon detectors and are attractive because they permit simultaneous time, energy and spatial resolution of faint astronomical sources. We present a cost-effective alternative to dedicated (e.g. analogue) electronics for prototyping readout of single-pixel Optical/NIR MKIDs by repurposing existing and well-known ROACH-1 boards. We also p…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are cryogenic photon detectors and are attractive because they permit simultaneous time, energy and spatial resolution of faint astronomical sources. We present a cost-effective alternative to dedicated (e.g. analogue) electronics for prototyping readout of single-pixel Optical/NIR MKIDs by repurposing existing and well-known ROACH-1 boards. We also present a pipeline that modernises previously-developed software and data frameworks to allow for extensiblity to new applications and portability to new hardware (e.g. Xilinx ZCU111 or 2x2 RFSoC boards).
△ Less
Submitted 17 January, 2023;
originally announced January 2023.
-
Modeling Results and Baseline Design for an RF-SoC-Based Readout System for Microwave Kinetic Inductance Detectors
Authors:
Colm Bracken,
Eoin Baldwin,
Gerhard Ulbricht,
Mario de Lucia,
Tom Ray
Abstract:
Building upon existing signal processing techniques and open-source software, this paper presents a baseline design for an RF System-on-Chip Frequency Division Multiplexed readout for a spatio-spectral focal plane instrument based on low temperature detectors. A trade-off analysis of different FPGA carrier boards is presented in an attempt to find an optimum next-generation solution for reading ou…
▽ More
Building upon existing signal processing techniques and open-source software, this paper presents a baseline design for an RF System-on-Chip Frequency Division Multiplexed readout for a spatio-spectral focal plane instrument based on low temperature detectors. A trade-off analysis of different FPGA carrier boards is presented in an attempt to find an optimum next-generation solution for reading out larger arrays of Microwave Kinetic Inductance Detectors (MKIDs). The ZCU111 RF SoC FPGA board from Xilinx was selected, and it is shown how this integrated system promises to increase the number of pixels that can be read out (per board) which enables a reduction in the readout cost per pixel, the mass and volume, and power consumption, all of which are important in making MKID instruments more feasible for both ground-based and space-based astrophysics. The on-chip logic capacity is shown to form a primary constraint on the number of MKIDs which can be read, channelised, and processed with this new system. As such, novel signal processing techniques are analysed, including Digitally Down Converted (DDC)-corrected sub-maximally decimated sampling, in an effort to reduce logic requirements without compromising signal to noise ratio. It is also shown how combining the ZCU111 board with a secondary FPGA board will allow all 8 ADCs and 8 DACs to be utilised, providing enough bandwidth to read up to 8,000 MKIDs per board-set, an eight-fold improvement over the state-of-the-art, and important in pursuing 100,000 pixel arrays. Finally, the feasibility of extending the operational frequency range of MKIDs to the 5 - 10 GHz regime (or possibly beyond) is investigated, and some benefits and consequences of doing so are presented.
△ Less
Submitted 9 February, 2023; v1 submitted 15 December, 2022;
originally announced December 2022.
-
Multiplexable frequency retuning of MKID arrays using their non-linear kinetic inductance
Authors:
Mario De Lucia,
Eoin Baldwin,
Gerhard Ulbricht,
Colm Bracken,
Plamen Stamenov,
Tom Ray
Abstract:
Microwave Kinetic Inductance Detector (MKID) arrays are currently being developed and deployed for astronomical applications in the visible and near infrared and for sub-millimetre astronomy. One of the main drawbacks of MKIDs is that large arrays would exhibit a pixel yield, the percentage of individually distinguishable pixels to the total number of pixels, of 75 - 80 %. Imperfections arising du…
▽ More
Microwave Kinetic Inductance Detector (MKID) arrays are currently being developed and deployed for astronomical applications in the visible and near infrared and for sub-millimetre astronomy. One of the main drawbacks of MKIDs is that large arrays would exhibit a pixel yield, the percentage of individually distinguishable pixels to the total number of pixels, of 75 - 80 %. Imperfections arising during the fabrication can induce an uncontrolled shift in the resonance frequency of individual resonators which can end up resonating at the same frequency of a different resonator. This makes a number of resonators indistinguishable and therefore unusable for imaging. This paper proposes an approach to individually re-tune the colliding resonators in order to remove the degeneracy and increase the number of MKIDs with unique resonant frequencies. The frequency re-tuning is achieved through a DC bias of the resonator, the kinetic inductance of a superconducting thin film is current dependent and its dependence is non linear. Even though this approach has been already proposed, an innovative pixel design, described in this paper, may solve two issues previously described in literature such as increased electromagnetic losses to the DC-bias line, and the multiplexibility of multiple resonators on a single feedline.
△ Less
Submitted 12 April, 2022;
originally announced April 2022.
-
Applications for Microwave Kinetic Induction Detectors in Advanced Instrumentation
Authors:
Gerhard Ulbricht,
Mario De Lucia,
Eoin Baldwin
Abstract:
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKI…
▽ More
In recent years Microwave Kinetic Inductance Detectors (MKIDs) have emerged as one of the most promising novel low temperature detector technologies. Their unrivaled scalability makes them very attractive for many modern applications and scientific instruments. In this paper we intend to give an overview of how and where MKIDs are currently being used or are suggested to be used in the future. MKID based projects are ongoing or proposed for observational astronomy, particle physics, material science and THz imaging, and the goal of this review is to provide an easily usable and thorough list of possible starting points for more in-depth literature research on the many areas profiting from kinetic inductance detectors.
△ Less
Submitted 16 November, 2021;
originally announced November 2021.
-
10 New Very Low Mass Close Binaries Resolved in the Visible
Authors:
Nicholas M. Law,
Simon T. Hodgkin,
Craig D. Mackay,
John E. Baldwin
Abstract:
We present preliminary results from the first part of the LuckyCam late M-dwarf binarity survey. We survey a sample of 48 nearby ($<$40 pc) and red (M5-M9) stars with the novel high angular resolution visible light imaging technique Lucky Imaging, in only 8 hours of 2.5m telescope time. We discover 10 new binaries; although the survey is sensitive to brown dwarf companions none are detected. The…
▽ More
We present preliminary results from the first part of the LuckyCam late M-dwarf binarity survey. We survey a sample of 48 nearby ($<$40 pc) and red (M5-M9) stars with the novel high angular resolution visible light imaging technique Lucky Imaging, in only 8 hours of 2.5m telescope time. We discover 10 new binaries; although the survey is sensitive to brown dwarf companions none are detected. The orbital radius distribution of the newly discovered binaries broadly matches that of previous detections by other groups, although we do discover one wide binary at ~40AU.
△ Less
Submitted 7 December, 2005;
originally announced December 2005.
-
Lucky Imaging: High Angular Resolution Imaging in the Visible from the Ground
Authors:
Nicholas M. Law,
Craig D. Mackay,
John E. Baldwin
Abstract:
We use a Lucky Imaging system to obtain I-band images with much improved angular resolution on a ground-based 2.5m telescope. We present results from a 10-night assessment campaign on the 2.56m Nordic Optical Telescope and quantify the performance of our system in seeings better than 1.0''. In good seeing we have acquired near diffraction-limited images; in poorer seeing the angular resolution h…
▽ More
We use a Lucky Imaging system to obtain I-band images with much improved angular resolution on a ground-based 2.5m telescope. We present results from a 10-night assessment campaign on the 2.56m Nordic Optical Telescope and quantify the performance of our system in seeings better than 1.0''. In good seeing we have acquired near diffraction-limited images; in poorer seeing the angular resolution has been routinely improved by factors of 2.5-4. The system can use guide stars as faint as I=16 with full performance and its useful field of view is consistently larger than 40" diameter. The technique shows promise for a number of science programmes, both galactic (eg. binary candidates, brown dwarfs, globular cluster cores) and extragalactic (eg. quasar host galaxies, damped Lyman-alpha absorbers).
△ Less
Submitted 13 July, 2005;
originally announced July 2005.
-
The Changing Blazhko Effect of XZ Cygni
Authors:
Aaron LaCluyze,
Horace A. Smith,
E. -M. Gill,
A. Hedden,
Karen Kinemuchi,
A. M. Rosas,
Barton J. Pritzl,
Brian Sharpee,
Christopher Wilkinson,
K. W. Robinson,
Marvin E. Baldwin,
Gerard Samolyk
Abstract:
New CCD photometry has been obtained for the RR Lyrae variable star XZ Cygni. An analysis of old and new photometry confirms earlier results that XZ Cygni exhibits the Blazhko Effect and that its Blazhko period has changed over time. These changes in the Blazhko period are anticorrelated with observed changes in the primary period of XZ Cygni. During the first half of the twentieth century, XZ C…
▽ More
New CCD photometry has been obtained for the RR Lyrae variable star XZ Cygni. An analysis of old and new photometry confirms earlier results that XZ Cygni exhibits the Blazhko Effect and that its Blazhko period has changed over time. These changes in the Blazhko period are anticorrelated with observed changes in the primary period of XZ Cygni. During the first half of the twentieth century, XZ Cygni had a Blazhko period of approximately 57.4 d. Beginning in 1965, its primary period underwent a steep decline in several steps. Coincidentally, its Blazhko period increased to about 58.5 d. In 1979, the primary period suddenly increased again. After an interval in which the Blazhko Effect was small, the Blazhko Effect re-established itself, with a period of approximately 57.5 d. When its Blazhko period is near 57.5 d, XZ Cygni has also shown a tertiary period of 41.6 d. We confirm that there is evidence for a longer 3540 d period in photometry obtained during the first half of the twentieth century. XZ Cygni is compared with three other RR Lyrae stars which also appear to show changing Blazhko periods. The observed changes in the length of the Blazhko period of XZ Cygni constrain possible explanations for the Blazhko Effect. In particular, they argue against any theoretical explanation which requires that the Blazhko period be exactly equal to or directly proportional to the rotation period of the star.
△ Less
Submitted 20 January, 2004; v1 submitted 15 January, 2004;
originally announced January 2004.
-
Diffraction-limited CCD imaging with faint reference stars
Authors:
R. N. Tubbs,
J. E. Baldwin,
C. D. Mackay,
G. C. Cox
Abstract:
By selecting short exposure images taken using a CCD with negligible readout noise we obtained essentially diffraction-limited 810 nm images of faint objects using nearby reference stars brighter than I=16 at a 2.56 m telescope. The FWHM of the isoplanatic patch for the technique is found to be 50 arcseconds, providing ~20% sky coverage around suitable reference stars.
By selecting short exposure images taken using a CCD with negligible readout noise we obtained essentially diffraction-limited 810 nm images of faint objects using nearby reference stars brighter than I=16 at a 2.56 m telescope. The FWHM of the isoplanatic patch for the technique is found to be 50 arcseconds, providing ~20% sky coverage around suitable reference stars.
△ Less
Submitted 26 March, 2002;
originally announced March 2002.
-
Diffraction-limited 800nm imaging with the 2.56m Nordic Optical Telescope
Authors:
J. E. Baldwin,
R. N. Tubbs,
G. C. Cox,
C. D. Mackay,
R. W. Wilson,
M. I. Andersen
Abstract:
A quantitative assessment is presented of diffraction-limited stellar images with Strehl ratios of 0.25-0.30 obtained by selection of short-exposure CCD images of stars brighter than +6m at 810nm with the Nordic Optical Telescope.
A quantitative assessment is presented of diffraction-limited stellar images with Strehl ratios of 0.25-0.30 obtained by selection of short-exposure CCD images of stars brighter than +6m at 810nm with the Nordic Optical Telescope.
△ Less
Submitted 23 January, 2001;
originally announced January 2001.