In-orbit Performance of the Soft X-ray Imaging Telescope Xtend aboard XRISM
Authors:
Hiroyuki Uchida,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroshi Murakami,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Kawabata Nobukawa,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Go Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Tessei Yoshida,
Yoshiaki Kanemaru,
Daiki Ishi,
Tadayasu Dotani
, et al. (40 additional authors not shown)
Abstract:
We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy ran…
▽ More
We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy range of 0.4--13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170--180 eV at 6 keV, which meets the mission requirement and enables to resolve He-like and H-like Fe K$α$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in SXI onboard the previous Hitomi mission -- light leakage and crosstalk events -- are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C273 results in an effective area measured to be $\sim420$ cm$^{2}[email protected] keV and $\sim310$ cm$^{2}[email protected] keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations: the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared to other major X-ray instruments onboard satellites, combined with the largest grasp ($Ω_{\rm eff}\sim60$ ${\rm cm^2~degree^2}$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.
△ Less
Submitted 25 March, 2025;
originally announced March 2025.
-
New CCD Driving Technique to Suppress Anomalous Charge Intrusion from Outside the Imaging Area for Soft X-ray Imager of Xtend onboard XRISM
Authors:
Hirofumi Noda,
Mio Aoyagi,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiromasa Suzuki,
Hiroshi Murakami,
Hiroyuki Uchida,
Takeshi G. Tsuru,
Keitaro Miyazaki,
Kohei Kusunoki,
Yoshiaki Kanemaru,
Yuma Aoki,
Kumiko Nobukawa,
Masayoshi Nobukawa,
Kohei Shima,
Marina Yoshimoto,
Kazunori Asakura,
Hironori Matsumoto,
Tomokage Yoneyama,
Shogo B. Kobayashi,
Kouichi Hagino,
Hideki Uchiyama,
Kiyoshi Hayashida
Abstract:
The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside…
▽ More
The Soft X-ray Imager (SXI) is an X-ray CCD camera of the Xtend system onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), which was successfully launched on September 7, 2023 (JST). During ground cooling tests of the CCDs in 2020/2021, using the flight-model detector housing, electronic boards, and a mechanical cooler, we encountered an unexpected issue. Anomalous charges appeared outside the imaging area of the CCDs and intruded into the imaging area, causing pulse heights to stick to the maximum value over a wide region. Although this issue has not occurred in subsequent tests or in orbit so far, it could seriously affect the imaging and spectroscopic performance of the SXI if it were to happen in the future. Through experiments with non-flight-model detector components, we successfully reproduced the issue and identified that the anomalous charges intrude via the potential structure created by the charge injection electrode at the top of the imaging area. To prevent anomalous charge intrusion and maintain imaging and spectroscopic performance that satisfies the requirements, even if this issue occurs in orbit, we developed a new CCD driving technique. This technique is different from the normal operation in terms of potential structure and its changes during imaging and charge injection. In this paper, we report an overview of the anomalous charge issue, the related potential structures, the development of the new CCD driving technique to prevent the issue, the imaging and spectroscopic performance of the new technique, and the results of experiments to investigate the cause of anomalous charges.
△ Less
Submitted 9 March, 2025;
originally announced March 2025.
-
Soft X-ray Imager of the Xtend system onboard XRISM
Authors:
Hirofumi Noda,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Go Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Tessei Yoshida,
Yoshiaki Kanemaru,
Junko Hiraga,
Tadayasu Dotani
, et al. (35 additional authors not shown)
Abstract:
The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and…
▽ More
The Soft X-ray Imager (SXI) is the X-ray charge-coupled device (CCD) camera for the soft X-ray imaging telescope Xtend installed on the X-ray Imaging and Spectroscopy Mission (XRISM), which was adopted as a recovery mission for the Hitomi X-ray satellite and was successfully launched on 2023 September 7 (JST). In order to maximize the science output of XRISM, we set the requirements for Xtend and find that the CCD set employed in the Hitomi/SXI or similar, i.e., a $2 \times 2$ array of back-illuminated CCDs with a $200~μ$m-thick depletion layer, would be practically best among available choices, when used in combination with the X-ray mirror assembly. We design the XRISM/SXI, based on the Hitomi/SXI, to have a wide field of view of $38' \times 38'$ in the $0.4-13$ keV energy range. We incorporated several significant improvements from the Hitomi/SXI into the CCD chip design to enhance the optical-light blocking capability and to increase the cosmic-ray tolerance, reducing the degradation of charge-transfer efficiency in orbit. By the time of the launch of XRISM, the imaging and spectroscopic capabilities of the SXI has been extensively studied in on-ground experiments with the full flight-model configuration or equivalent setups and confirmed to meet the requirements. The optical blocking capability, the cooling and temperature control performance, and the transmissivity and quantum efficiency to incident X-rays of the CCDs are also all confirmed to meet the requirements. Thus, we successfully complete the pre-flight development of the SXI for XRISM.
△ Less
Submitted 11 February, 2025;
originally announced February 2025.
-
Feasibility study of upper atmosphere density measurement on the ISS by observations of the CXB transmitted through the Earth rim
Authors:
Takumi Kishimoto,
Kumiko K. Nobukawa,
Ayaki Takeda,
Takeshi G. Tsuru,
Satoru Katsuda,
Nakazawa Kazuhiro,
Koji Mori,
Masayoshi Nobukawa,
Hiroyuki Uchida,
Yoshihisa Kawabe,
Satoru Kuwano,
Eisuke Kurogi,
Yamato Ito,
Yuma Aoki
Abstract:
Measurements of the upper atmosphere at ~100 km are important to investigate climate change, space weather forecasting, and the interaction between the Sun and the Earth. Atmospheric occultations of cosmic X-ray sources are an effective technique to measure the neutral density in the upper atmosphere. We are developing the instrument SUIM dedicated to continuous observations of atmospheric occulta…
▽ More
Measurements of the upper atmosphere at ~100 km are important to investigate climate change, space weather forecasting, and the interaction between the Sun and the Earth. Atmospheric occultations of cosmic X-ray sources are an effective technique to measure the neutral density in the upper atmosphere. We are developing the instrument SUIM dedicated to continuous observations of atmospheric occultations. SUIM will be mounted on a platform on the exterior of the International Space Station for six months and pointed at the Earth's rim to observe atmospheric absorption of the cosmic X-ray background (CXB). In this paper, we conducted a feasibility study of SUIM by estimating the CXB statistics and the fraction of the non-X-ray background (NXB) in the observed data. The estimated CXB statistics are enough to evaluate the atmospheric absorption of CXB for every 15 km of altitude. On the other hand, the NXB will be dominant in the X-ray spectra of SUIM. Assuming that the NXB per detection area of SUIM is comparable to that of the soft X-ray Imager onboard Hitomi, the NXB level will be much higher than the CXB one and account for ~80% of the total SUIM spectra.
△ Less
Submitted 26 July, 2024;
originally announced July 2024.
-
SUIM project: measuring the upper atmosphere from the ISS by observations of the CXB transmitted through the Earth rim
Authors:
Kumiko K. Nobukawa,
Ayaki Takeda,
Satoru Katsuda,
Takeshi G. Tsuru,
Kazuhiro Nakazawa,
Koji Mori,
Hiroyuki Uchida,
Masayoshi Nobukawa,
Eisuke Kurogi,
Takumi Kishimoto,
Reo Matsui,
Yuma Aoki,
Yamato Ito,
Satoru Kuwano,
Tomitaka Tanaka,
Mizuki Uenomachi,
Masamune Matsuda,
Takaya Yamawaki,
Takayoshi Kohmura
Abstract:
The upper atmosphere at the altitude of 60-110 km, the mesosphere and lower thermosphere (MLT), has the least observational data of all atmospheres due to the difficulties of in-situ observations. Previous studies demonstrated that atmospheric occultation of cosmic X-ray sources is an effective technique to investigate the MLT. Aiming to measure the atmospheric density of the MLT continuously, we…
▽ More
The upper atmosphere at the altitude of 60-110 km, the mesosphere and lower thermosphere (MLT), has the least observational data of all atmospheres due to the difficulties of in-situ observations. Previous studies demonstrated that atmospheric occultation of cosmic X-ray sources is an effective technique to investigate the MLT. Aiming to measure the atmospheric density of the MLT continuously, we are developing an X-ray camera, "Soipix for observing Upper atmosphere as Iss experiment Mission (SUIM)", dedicated to atmospheric observations. SUIM will be installed on the exposed area of the International Space Station (ISS) and face the ram direction of the ISS to point toward the Earth rim. Observing the cosmic X-ray background (CXB) transmitted through the atmosphere, we will measure the absorption column density via spectroscopy and thus obtain the density of the upper atmosphere. The X-ray camera is composed of a slit collimator and two X-ray SOI-CMOS pixel sensors (SOIPIX), and will stand on its own and make observations, controlled by a CPU-embedded FPGA "Zynq". We plan to install the SUIM payload on the ISS in 2025 during the solar maximum. In this paper, we report the overview and the development status of this project.
△ Less
Submitted 23 July, 2024;
originally announced July 2024.
-
Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Hiroyuki Uchida,
Hiromasa Suzuki,
Shogo Benjamin Kobayashi,
Tomokage Yoneyama,
Kouichi Hagino,
Kumiko Nobukawa,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Hirokazu Odaka,
Takayoshi Kohmura,
Kazutaka Yamaoka,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi
, et al. (38 additional authors not shown)
Abstract:
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is…
▽ More
Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.
△ Less
Submitted 28 June, 2024;
originally announced June 2024.
-
Initial operations of the Soft X-ray Imager onboard XRISM
Authors:
Hiromasa Suzuki,
Tomokage Yoneyama,
Shogo B. Kobayashi,
Hirofumi Noda,
Hiroyuki Uchida,
Kumiko K. Nobukawa,
Kouichi Hagino,
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takaaki Tanaka,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Yoshiaki Kanemaru,
Yoshinori Otsuka,
Haruhiko Yokosu,
Wakana Yonemaru,
Hanako Nakano,
Kazuhiro Ichikawa,
Reo Takemoto,
Tsukasa Matsushima,
Marina Yoshimoto,
Mio Aoyagi,
Kohei Shima
, et al. (30 additional authors not shown)
Abstract:
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and…
▽ More
XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the small window modes, and event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.
△ Less
Submitted 14 February, 2025; v1 submitted 28 June, 2024;
originally announced June 2024.
-
Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)
Authors:
Koji Mori,
Hiroshi Tomida,
Hiroshi Nakajima,
Takashi Okajima,
Hirofumi Noda,
Takaaki Tanaka,
Hiroyuki Uchida,
Kouichi Hagino,
Shogo Benjamin Kobayashi,
Hiromasa Suzuki,
Tessei Yoshida,
Hiroshi Murakami,
Hideki Uchiyama,
Masayoshi Nobukawa,
Kumiko Nobukawa,
Tomokage Yoneyama,
Hironori Matsumoto,
Takeshi Tsuru,
Makoto Yamauchi,
Isamu Hatsukade,
Manabu Ishida,
Yoshitomo Maeda,
Takayuki Hayashi,
Keisuke Tamura,
Rozenn Boissay-Malaquin
, et al. (30 additional authors not shown)
Abstract:
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an…
▽ More
Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.
△ Less
Submitted 13 March, 2023;
originally announced March 2023.