-
Galactic Cosmic Rays at Mars and Venus: Temporal Variations from Hours to Decades Measured as the Background Signal of Onboard Micro-Channel Plates
Authors:
Yoshifumi Futaana,
Manabu Shimoyama,
Martin Wieser,
Stefan Karlsson,
Herman Andersson,
Hans Nilsson,
Xiao-Dong Wang,
Andrey Fedorov,
Nicolas Andre,
Mats Holmström,
Stas Barabash
Abstract:
A Micro-Channel Plate (MCP) is a widely used component for counting particles in space. Using the background counts of MCPs on Mars Express and Venus Express orbiters operated over 17 years and 8 years, respectively, we investigate the galactic cosmic ray (GCR) characteristics in the inner solar system. The MCP background counts at Mars and Venus on a solar cycle time scale exhibit clear anti-corr…
▽ More
A Micro-Channel Plate (MCP) is a widely used component for counting particles in space. Using the background counts of MCPs on Mars Express and Venus Express orbiters operated over 17 years and 8 years, respectively, we investigate the galactic cosmic ray (GCR) characteristics in the inner solar system. The MCP background counts at Mars and Venus on a solar cycle time scale exhibit clear anti-correlation to the sunspot number. We conclude that the measured MCP background contain the GCR information. The GCR characteristics measured using the MCP background at Mars show features that are consistent with the ground-based measurement in solar cycle 24. The time lag between the sunspot number and the MCP background at Mars is found ~9 months. The shorter-term background data recorded along the orbits (with a time scale of several hours) also show evident depletion of the background counts due to the absorption of the GCR particles by the planets. Thanks to the visible planetary size change along an orbit, the GCR contribution to the MCP background can be separated from the internal contribution due to the \b{eta}-decay. Our statistical analysis of the GCR absorption signatures at Mars implies that the effective absorption size of Mars for the GCR particles have a >100 km larger radius than the solid Martian body.
△ Less
Submitted 4 April, 2022;
originally announced April 2022.
-
The Instrument of the Imaging X-ray Polarimetry Explorer
Authors:
Paolo Soffitta,
Luca Baldini,
Ronaldo Bellazzini,
Enrico Costa,
Luca Latronico,
Fabio Muleri,
Ettore Del Monte,
Sergio Fabiani,
Massimo Minuti,
Michele Pinchera,
Carmelo Sgrò,
Gloria Spandre,
Alessio Trois,
Fabrizio Amici,
Hans Andersson,
Primo Attinà,
Matteo Bachetti,
Mattia Barbanera,
Fabio Borotto,
Alessandro Brez,
Daniele Brienza,
Ciro Caporale,
Claudia Cardelli,
Rita Carpentiero,
Simone Castellano
, et al. (56 additional authors not shown)
Abstract:
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detecto…
▽ More
While X-ray Spectroscopy, Timing and Imaging have improved verymuch since 1962, when the first astronomical non-solar source was discovered, especially with the launch of Newton/X-ray Multi-Mirror Mission, Rossi/X-ray Timing Explorer and Chandra/Advanced X-ray Astrophysics Facility, the progress of X-ray polarimetry has been meager. This is in part due to the lack of sensitive polarization detectors, in part due to the fate of approved missions and in part because the celestial X-ray sources appeared less polarized than expected. Only one positive measurement has been available until now. Indeed the eight Orbiting Solar Observatory measured the polarization of the Crab nebula in the 70s.
The advent of techniques of microelectronics allowed for designing a detector based on the photoelectric effect in gas in an energy range where the optics are efficient in focusing X-rays. Herewe describe the Instrument, which is the major contribution of the Italian collaboration to the SmallExplorer mission called IXPE, the Imaging X-ray Polarimetry Explorer, which will be flown in late 2021. The instrument, is composed of three Detector Units, based on this technique, and a Detector Service Unit. Three Mirror Modules provided by Marshall Space Flight Center focus X-rays onto the detectors. In the following we will show the technological choices, their scientific motivation and the results from the calibration of the Instrument.
IXPE will perform imaging, timing and energy resolved polarimetry in the 2-8 keV energy band opening this window of X-ray astronomy to tens of celestial sources of almost all classes.
△ Less
Submitted 31 July, 2021;
originally announced August 2021.
-
Design, Construction, and Test of the Gas Pixel Detectors for the IXPE Mission
Authors:
L. Baldini,
M. Barbanera,
R. Bellazzini,
R. Bonino,
F. Borotto,
A. Brez,
C. Caporale,
C. Cardelli,
S. Castellano,
M. Ceccanti,
S. Citraro,
N. Di Lalla,
L. Latronico,
L. Lucchesi,
C. Magazzù,
G. Magazzù,
S. Maldera,
A. Manfreda,
M. Marengo,
A. Marrocchesi,
P. Mereu,
M. Minuti,
F. Mosti,
H. Nasimi,
A. Nuti
, et al. (69 additional authors not shown)
Abstract:
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collectin…
▽ More
Due to be launched in late 2021, the Imaging X-Ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission designed to perform polarization measurements in the 2-8 keV band, complemented with imaging, spectroscopy and timing capabilities. At the heart of the focal plane is a set of three polarization-sensitive Gas Pixel Detectors (GPD), each based on a custom ASIC acting as a charge-collecting anode. In this paper we shall review the design, manufacturing, and test of the IXPE focal-plane detectors, with particular emphasis on the connection between the science drivers, the performance metrics and the operational aspects. We shall present a thorough characterization of the GPDs in terms of effective noise, trigger efficiency, dead time, uniformity of response, and spectral and polarimetric performance. In addition, we shall discuss in detail a number of instrumental effects that are relevant for high-level science analysis -- particularly as far as the response to unpolarized radiation and the stability in time are concerned.
△ Less
Submitted 12 July, 2021;
originally announced July 2021.
-
Double-Layer Silicon PIN Photodiode X-Ray Detector for a Future X-ray Timing Mission
Authors:
Hua Feng,
Philip Kaaret,
Hans Andersson
Abstract:
A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective area of 6 mm^2. The detector performs best at -35 C with an energy resolution of 220 eV (FWHM, full width at half maximum) at 5.9 keV, and is able to operate at…
▽ More
A double-layer silicon detector consisting of two 500micron-thick silicon PIN photodiodes with independent readouts was mounted in a vacuum chamber and tested with X-ray sources. The detector is sensitive from 1-30 keV with an effective area of 6 mm^2. The detector performs best at -35 C with an energy resolution of 220 eV (FWHM, full width at half maximum) at 5.9 keV, and is able to operate at room temperature, +25 C, with moderate resolution around 760 eV (FWHM). The response of the top layer sensor is highly uniform across the sensitive area. This large-format silicon detector is appropriate for future X-ray timing missions.
△ Less
Submitted 1 June, 2006;
originally announced June 2006.
-
Carbon Abundances in F and G Dwarfs
Authors:
Helena Andersson,
Bengt Edvardsson
Abstract:
We have determined carbon abundances or upper limits from the forbidden [C I] line at 8727.13 A for 85 F and early G type main sequence stars, with metallicities ranging between [Fe/H] = -1.0 and [Fe/H] = +0.25. The [C I] line has not been previously used for a study of this size. We find that the C/Fe abundance ratio is slowly decreasing with time and increasing metallicity in the disk, but wit…
▽ More
We have determined carbon abundances or upper limits from the forbidden [C I] line at 8727.13 A for 85 F and early G type main sequence stars, with metallicities ranging between [Fe/H] = -1.0 and [Fe/H] = +0.25. The [C I] line has not been previously used for a study of this size. We find that the C/Fe abundance ratio is slowly decreasing with time and increasing metallicity in the disk, but with considerable observational scatter. A discussion of results in the literature supports this result. Our data do not reveal any gradients with galactocentric birth distance for our stars, but more accurate observations are desirable since possible gradients should be important to the question of the synthesis of C and Fe in the disk. (Accepted for publication in A&A. Postscript text and figures available via anonymous ftp to "chiron.astro.uu.se", in directory "pub/articles/atmos/P89")
△ Less
Submitted 22 June, 1994;
originally announced June 1994.