-
A torsion-balance search for ultra low-mass bosonic dark matter
Authors:
E. A. Shaw,
M. P. Ross,
C. A. Hagedorn,
E. G. Adelberger,
J. H. Gundlach
Abstract:
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining…
▽ More
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining $g_{B-L}(\hbar c)^{-1/2} < 1 \times 10^{-25}$. This provides a complimentary limit to equivalence-principle experiments that search for ultra low-mass bosons as force-mediating particles.
△ Less
Submitted 10 January, 2022; v1 submitted 17 September, 2021;
originally announced September 2021.
-
Constraints on axionlike dark matter with masses down to $10^{-23}$ eV/c$^2$
Authors:
William A. Terrano,
Eric G. Adelberger,
Charles A. Hagedorn,
Blayne R. Heckel
Abstract:
We analyzed an 6.7-year span of data from a rotating torsion-pendulum containing $\approx 10^{23}$ polarized electrons to search for the "wind" arising from ultralight, axionlike dark matter with masses between $10^{-23}$ and $10^{-18}$ eV/c$^2$. Over most of this range we obtain a 95\% confidence limit $F_{\rm a}/C_{\rm e} \geq 1 \times 10^{15}$ eV on the axionlike decay constant.
We analyzed an 6.7-year span of data from a rotating torsion-pendulum containing $\approx 10^{23}$ polarized electrons to search for the "wind" arising from ultralight, axionlike dark matter with masses between $10^{-23}$ and $10^{-18}$ eV/c$^2$. Over most of this range we obtain a 95\% confidence limit $F_{\rm a}/C_{\rm e} \geq 1 \times 10^{15}$ eV on the axionlike decay constant.
△ Less
Submitted 28 May, 2019; v1 submitted 12 February, 2019;
originally announced February 2019.
-
An absolute calibration system for millimeter-accuracy APOLLO measurements
Authors:
E. G. Adelberger,
J. B. R. Battat,
K. J. Birkmeier,
N. R. Colmenares,
R. Davis,
C. D. Hoyle,
L. R. Huang,
R. J. McMillan,
T. W. Murphy Jr.,
E. Schlerman,
C. Skrobol,
C. W. Stubbs,
A. Zach
Abstract:
Lunar laser ranging provides a number of leading experimental tests of gravitation -- important in our quest to unify General Relativity and the Standard Model of physics. The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) has for years achieved median range precision at the ~2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the q…
▽ More
Lunar laser ranging provides a number of leading experimental tests of gravitation -- important in our quest to unify General Relativity and the Standard Model of physics. The Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) has for years achieved median range precision at the ~2 mm level. Yet residuals in model-measurement comparisons are an order-of-magnitude larger, raising the question of whether the ranging data are not nearly as accurate as they are precise, or if the models are incomplete or ill-conditioned. This paper describes a new absolute calibration system (ACS) intended both as a tool for exposing and eliminating sources of systematic error, and also as a means to directly calibrate ranging data in-situ. The system consists of a high-repetition-rate (80 MHz) laser emitting short (< 10 ps) pulses that are locked to a cesium clock. In essence, the ACS delivers photons to the APOLLO detector at exquisitely well-defined time intervals as a "truth" input against which APOLLO's timing performance may be judged and corrected. Preliminary analysis indicates no inaccuracies in APOLLO data beyond the ~3 mm level, suggesting that historical APOLLO data are of high quality and motivating continued work on model capabilities. The ACS provides the means to deliver APOLLO data both accurate and precise below the 2 mm level.
△ Less
Submitted 28 June, 2017;
originally announced June 2017.
-
Laser Ranging to the Lost Lunokhod~1 Reflector
Authors:
T. W. Murphy Jr,
E. G. Adelberger,
J. B. R. Battat,
C. D. Hoyle,
N. H. Johnson,
R. J. McMillan,
E. L. Michelsen,
C. W. Stubbs,
H. E. Swanson
Abstract:
In 1970, the Soviet Lunokhod 1 rover delivered a French-built laser reflector to the Moon. Although a few range measurements were made within three months of its landing, these measurements---and any that may have followed---are unpublished and unavailable. The Lunokhod 1 reflector was, therefore, effectively lost until March of 2010 when images from the Lunar Reconnaissance Orbiter (LRO) provided…
▽ More
In 1970, the Soviet Lunokhod 1 rover delivered a French-built laser reflector to the Moon. Although a few range measurements were made within three months of its landing, these measurements---and any that may have followed---are unpublished and unavailable. The Lunokhod 1 reflector was, therefore, effectively lost until March of 2010 when images from the Lunar Reconnaissance Orbiter (LRO) provided a positive identification of the rover and determined its coordinates with uncertainties of about 100 m. This allowed the Apache Point Observatory Lunar Laser-ranging Operation (APOLLO) to quickly acquire a laser signal. The reflector appears to be in excellent condition, delivering a signal roughly four times stronger than its twin reflector on the Lunokhod 2 rover. The Lunokhod 1 reflector is especially valuable for science because it is closer to the Moon's limb than any of the other reflectors and, unlike the Lunokhod 2 reflector, we find that it is usable during the lunar day. We report the selenographic position of the reflector to few-centimeter accuracy, comment on the health of the reflector, and illustrate the value of this reflector for achieving science goals.
△ Less
Submitted 4 November, 2010; v1 submitted 28 September, 2010;
originally announced September 2010.
-
Solar fusion cross sections II: the pp chain and CNO cycles
Authors:
E. G. Adelberger,
A. B. Balantekin,
D. Bemmerer,
C. A. Bertulani,
J. -W. Chen,
H. Costantini,
M. Couder,
R. Cyburt,
B. Davids,
S. J. Freedman,
M. Gai,
A. Garcia,
D. Gazit,
L. Gialanella,
U. Greife,
M. Hass,
K. Heeger,
W. C. Haxton,
G. Imbriani,
T. Itahashi,
A. Junghans,
K. Kubodera,
K. Langanke,
D. Leitner,
M. Leitner
, et al. (23 additional authors not shown)
Abstract:
We summarize and critically evaluate the available data on nuclear fusion cross sections important to energy generation in the Sun and other hydrogen-burning stars and to solar neutrino production. Recommended values and uncertainties are provided for key cross sections, and a recommended spectrum is given for 8B solar neutrinos. We also discuss opportunities for further increasing the precision o…
▽ More
We summarize and critically evaluate the available data on nuclear fusion cross sections important to energy generation in the Sun and other hydrogen-burning stars and to solar neutrino production. Recommended values and uncertainties are provided for key cross sections, and a recommended spectrum is given for 8B solar neutrinos. We also discuss opportunities for further increasing the precision of key rates, including new facilities, new experimental techniques, and improvements in theory. This review, which summarizes the conclusions of a workshop held at the Institute for Nuclear Theory, Seattle, in January 2009, is intended as a 10-year update and supplement to Reviews of Modern Physics 70 (1998) 1265.
△ Less
Submitted 10 October, 2010; v1 submitted 14 April, 2010;
originally announced April 2010.
-
Long-term degradation of optical devices on the moon
Authors:
T. W. Murphy, Jr.,
E. G. Adelberger,
J. B. R. Battat,
C. D. Hoyle,
R. J. McMillan,
E. L. Michelsen,
R. Samad,
C. W. Stubbs,
H. E. Swanson
Abstract:
Forty years ago, Apollo astronauts placed the first of several retroreflector arrays on the lunar surface. Their continued usefulness for laser-ranging might suggest that the lunar environment does not damage optical devices. However, new laser ranging data reveal that the efficiency of the three Apollo reflector arrays is now diminished by a factor of ten at all lunar phases and by an additiona…
▽ More
Forty years ago, Apollo astronauts placed the first of several retroreflector arrays on the lunar surface. Their continued usefulness for laser-ranging might suggest that the lunar environment does not damage optical devices. However, new laser ranging data reveal that the efficiency of the three Apollo reflector arrays is now diminished by a factor of ten at all lunar phases and by an additional factor of ten when the lunar phase is near full moon. These deficits did not exist in the earliest years of lunar ranging, indicating that the lunar environment damages optical equipment on the timescale of decades. Dust or abrasion on the front faces of the corner-cube prisms may be responsible, reducing their reflectivity and degrading their thermal performance when exposed to face-on sunlight at full moon. These mechanisms can be tested using laboratory simulations and must be understood before designing equipment destined for the moon.
△ Less
Submitted 2 March, 2010;
originally announced March 2010.
-
APOLLO: the Apache Point Observatory Lunar Laser-ranging Operation: Instrument Description and First Detections
Authors:
T. W. Murphy, Jr.,
E. G. Adelberger,
J. B. R. Battat,
L. N. Carey,
C. D. Hoyle,
P. LeBlanc,
E. L. Michelsen,
K. Nordtvedt,
A. E. Orin,
J. D. Strasburg,
C. W. Stubbs,
H. E. Swanson,
E. Williams
Abstract:
A next-generation lunar laser ranging apparatus using the 3.5 m telescope at the Apache Point Observatory in southern New Mexico has begun science operation. APOLLO (the Apache Point Observatory Lunar Laser-ranging Operation) has achieved one-millimeter range precision to the moon which should lead to approximately one-order-of-magnitude improvements in the precision of several tests of fundamen…
▽ More
A next-generation lunar laser ranging apparatus using the 3.5 m telescope at the Apache Point Observatory in southern New Mexico has begun science operation. APOLLO (the Apache Point Observatory Lunar Laser-ranging Operation) has achieved one-millimeter range precision to the moon which should lead to approximately one-order-of-magnitude improvements in the precision of several tests of fundamental properties of gravity. We briefly motivate the scientific goals, and then give a detailed discussion of the APOLLO instrumentation.
△ Less
Submitted 7 November, 2007; v1 submitted 3 October, 2007;
originally announced October 2007.
-
Tests of the Gravitational Inverse-Square Law
Authors:
E. G. Adelberger,
B. R. Heckel,
A. E. Nelson
Abstract:
We review recent experimental tests of the gravitational inverse-square law and the wide variety of theoretical considerations that suggest the law may break down in experimentally accessible regions.
We review recent experimental tests of the gravitational inverse-square law and the wide variety of theoretical considerations that suggest the law may break down in experimentally accessible regions.
△ Less
Submitted 22 July, 2003;
originally announced July 2003.
-
7Be(p,gamma)8B astrophysical S-factor from precision cross section measurements
Authors:
A. R. Junghans,
E. C. Mohrmann,
K. A. Snover,
T. D. Steiger,
E. G. Adelberger,
J. -M. Casandjian,
H. E. Swanson,
L. Buchmann,
S. H. Park,
A. Zyuzin
Abstract:
We measured the 7Be(p,gamma)8B cross section from E_cm = 186 to 1200 keV, with a statistical-plus-systematic precision per point of better than +- 5%. All important systematic errors were measured including 8B backscattering losses. We obtain S_17(0) = 22.3 +- 0.7(expt) +- 0.5(theor) eV-b from our data at E_cm <= 300 keV and the theory of Descouvemont and Baye.
We measured the 7Be(p,gamma)8B cross section from E_cm = 186 to 1200 keV, with a statistical-plus-systematic precision per point of better than +- 5%. All important systematic errors were measured including 8B backscattering losses. We obtain S_17(0) = 22.3 +- 0.7(expt) +- 0.5(theor) eV-b from our data at E_cm <= 300 keV and the theory of Descouvemont and Baye.
△ Less
Submitted 16 November, 2001;
originally announced November 2001.