Project TAIPAN: Results from a Novel Gravity Gradiometer Field Test
Authors:
Alexey V. Veryaskin,
Howard C. Golden,
Khyl J. McMahon,
Neil M. Provins,
Frank J. van Kann,
Thomas J. Meyer
Abstract:
Project TAIPAN has been carried out jointly by Trinity Research Lab and the Frequency and Quantum Metrology Research Group located at the School of Physics, Mathematics and Computing of the University of Western Australia (UWA). Lockheed Martin Corporation (USA) has also been a partner in this joint collaboration providing financial backing to the project and other support including advanced model…
▽ More
Project TAIPAN has been carried out jointly by Trinity Research Lab and the Frequency and Quantum Metrology Research Group located at the School of Physics, Mathematics and Computing of the University of Western Australia (UWA). Lockheed Martin Corporation (USA) has also been a partner in this joint collaboration providing financial backing to the project and other support including advanced modelling, assessment of laboratory tests and data analysis. The project aim was to develop a miniaturised gravity gradiometer to measure horizontal mixed gradient components of the Earth gravity in a small, lightweight package that can be deployed in a fixed 4D mode, in a borehole, or on moving exploration platforms including ground-based, airborne and submersible. The gradiometer design has evolved through a few prototypes combining the design of its sensing element with ultra low noise microwave and capacitive read out. The most recent prototype of the gradiometer using novel ultra sensitive capacitive pick off metrology has been trialled in the harsh environment of Outback Western Australia over a known gravity anomaly displaying steep gradients. Despite adverse weather conditions, results of the trial indicate that the gradiometer operated as expected, closely replicating the gravity gradient profile extrapolated from a regional gravity survey.
△ Less
Submitted 23 November, 2024;
originally announced November 2024.
-
A Novel Capacitance-to-Phase Transducer Based on a Simple Resonant Circuit
Authors:
Frank J. van Kann,
Alexey V. Veryaskin
Abstract:
A novel room temperature capacitance-to-phase transducer is described, which uses a modified All-Pass filter architecture combined with a simple series resonant tank circuit with a moderate Q-factor. It is fashioned from a discrete inductor with small dissipation resonating with a grounded capacitor acting as the sensor, to obtain a relative resolution equal to or better than 10-11 in a 1 Hz bandw…
▽ More
A novel room temperature capacitance-to-phase transducer is described, which uses a modified All-Pass filter architecture combined with a simple series resonant tank circuit with a moderate Q-factor. It is fashioned from a discrete inductor with small dissipation resonating with a grounded capacitor acting as the sensor, to obtain a relative resolution equal to or better than 10-11 in a 1 Hz bandwidth. The transducer converts the change in capacitance to the change in the phase of a carrier signal at the resonance frequency and is configured to act as a close approximation of the almost ideal All-Pass filter. This cancels out the effects of amplitude modulation when the carrier signal is imperfectly tuned to the resonance. When used as a mechanical displacement-to-phase transducer, the predicted position noise was approximately 3 femtometre/rootHz. Other applications of the proposed circuit include the measurement of the electric field, where the sensing capacitor depends on the applied electric field. In addition, the circuit can be easily adapted to function with very small capacitance values (1 - 2 pF) as is typical in MEMS-based transducers.
△ Less
Submitted 27 December, 2023; v1 submitted 6 October, 2023;
originally announced October 2023.
-
Intercombination line frequencies in $^{171}$Yb validated with the clock transition
Authors:
Daniel M. Jones,
Frank van Kann,
John J. McFerran
Abstract:
We have carried absolute frequency measurements of the $(6s^{2})\,^{1}S_{0}$ $-$ $(6s6p)\,^{3}P_{1}$ transition in $^{171}$Yb (the intercombination line), where the spin-1/2 isotope yields two hyperfine lines. The measurements rely on sub-Doppler spectroscopy to yield a discriminator to which a 556 nm laser is locked. The frequency reference for the optical frequency measurements is a high-quality…
▽ More
We have carried absolute frequency measurements of the $(6s^{2})\,^{1}S_{0}$ $-$ $(6s6p)\,^{3}P_{1}$ transition in $^{171}$Yb (the intercombination line), where the spin-1/2 isotope yields two hyperfine lines. The measurements rely on sub-Doppler spectroscopy to yield a discriminator to which a 556 nm laser is locked. The frequency reference for the optical frequency measurements is a high-quality quartz oscillator steered to the GNSS timescale that is bridged with a frequency comb. The reference is validated to $\sim3\times10^{-12}$ by spectroscopy on the $^{1}S_{0}-\,^{3}P_{0}$ (clock) line in laser cooled and trapped $^{171}$Yb atoms. From the hyperfine separation between the $F=1/2$ and $F=3/2$ levels of $^{3}P_{1}$ we determine the hyperfine constant to be $A(^3P_1)= 3\,957\,833\,(28)$ kHz.
△ Less
Submitted 15 March, 2023;
originally announced March 2023.
-
Observation of the Fundamental Nyquist Noise Limit in an Ultra-High $Q$-Factor Cryogenic Bulk Acoustic Wave Cavity
Authors:
Maxim Goryachev,
Eugene N. Ivanov,
Frank van Kann,
Serge Galliou,
Michael E. Tobar
Abstract:
Thermal Nyquist noise fluctuations of high-$Q$ Bulk Acoustic Wave (BAW) cavities have been observed at cryogenic temperatures with a DC Superconducting Quantum Interference Device (SQUID) amplifier. High $Q$ modes with bandwidths of few tens of milliHz produce thermal fluctuations with a Signal-To-Noise ratio of up to 23dB. The estimated effective temperature from the Nyquist noise is in good agre…
▽ More
Thermal Nyquist noise fluctuations of high-$Q$ Bulk Acoustic Wave (BAW) cavities have been observed at cryogenic temperatures with a DC Superconducting Quantum Interference Device (SQUID) amplifier. High $Q$ modes with bandwidths of few tens of milliHz produce thermal fluctuations with a Signal-To-Noise ratio of up to 23dB. The estimated effective temperature from the Nyquist noise is in good agreement with the physical temperature of the device, confirming the validity of the equivalent circuit model and the non-existence of any excess resonator self-noise. The measurements also confirm that the quality factor remains extremely high ($Q>10^8$ at low order overtones) for very weak (thermal) system motion at low temperatures, when compared to values measured with relatively strong external excitation. This result represents an enabling step towards operating such a high-Q acoustic device at the standard quantum limit.
△ Less
Submitted 16 October, 2014;
originally announced October 2014.
-
Test of Lorentz Invariance in Electrodynamics Using Rotating Cryogenic Sapphire Microwave Oscillators
Authors:
Paul L. Stanwix,
Michael E. Tobar,
Peter Wolf,
Mohamad Susli,
Clayton R. Locke,
Eugene N. Ivanov,
John Winterflood,
Frank van Kann
Abstract:
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Man…
▽ More
We present the first results from a rotating Michelson-Morley experiment that uses two orthogonally orientated cryogenic sapphire resonator-oscillators operating in whispering gallery modes near 10 GHz. The experiment is used to test for violations of Lorentz Invariance in the frame-work of the photon sector of the Standard Model Extension (SME), as well as the isotropy term of the Robertson-Mansouri-Sexl (RMS) framework. In the SME we set a new bound on the previously unmeasured $\tildeκ_{e-}^{ZZ}$ component of $2.1(5.7)\times10^{-14}$, and set more stringent bounds by up to a factor of 7 on seven other components. In the RMS a more stringent bound of $-0.9(2.0)\times 10^{-10}$ on the isotropy parameter, $P_{MM}=δ- β+ {1/2}$ is set, which is more than a factor of 7 improvement. More detailed description of the experiment and calculations can be found in: hep-ph/0506200
△ Less
Submitted 21 July, 2005; v1 submitted 7 June, 2005;
originally announced June 2005.