-
An air-spaced virtually imaged phased array with 94 MHz resolution for precision spectroscopy
Authors:
Ibrahim Sadiek,
Norbert Lang,
Jean-Pierre H. van Helden
Abstract:
We report on an air-spaced virtually imaged phased array (VIPA) spectrometer that resolves the modes of a mid-infrared frequency comb with a repetition rate of 250 MHz, without an optical filter cavity. With a record spectral resolution of 94 MHz for VIPA, the spectrometer enables precision molecular spectroscopy with high resolution, broad spectral coverage and fast data acquisition. We demonstra…
▽ More
We report on an air-spaced virtually imaged phased array (VIPA) spectrometer that resolves the modes of a mid-infrared frequency comb with a repetition rate of 250 MHz, without an optical filter cavity. With a record spectral resolution of 94 MHz for VIPA, the spectrometer enables precision molecular spectroscopy with high resolution, broad spectral coverage and fast data acquisition. We demonstrate the capabilities of the spectrometer by measuring the absorption spectra of molecular species generated in plasmas. Using plasmas of a mixture of nitrogen, hydrogen, and methane at a low pressure of 1.5 mbar, we obtained high-resolution spectra of methane, around 3017 cm$^{-1}$, as well as hydrogen cyanide and ammonia, around 3240 cm$^{-1}$, demonstrating a wide spectral coverage over 290 cm$^{-1}$ (equivalent to 8.7 THz). The spectrometer performance in terms of Allan-Werle deviation and noise-equivalent absorption is discussed. The air-spaced VIPA concept offers a compact and practical spectrometer that harnesses the full potential of a stabilized frequency comb, making it suitable for a wide range of high-precision spectroscopic applications.
△ Less
Submitted 20 November, 2024;
originally announced November 2024.
-
Precision spectroscopy of non-thermal molecular plasmas using mid-infrared optical frequency comb Fourier transform spectroscopy
Authors:
Ibrahim Sadiek,
Alexander Puth,
Grzegorz Kowzan,
Akiko Nishiyama,
Sarah-Johanna Klose,
Jürgen Röpcke,
Norbert Lang,
Piotr Masłowski,
Jean-Pierre H. van Helden
Abstract:
Non-thermal molecular plasmas play a crucial role in numerous industrial processes and hold significant potential for driving essential chemical transformations. Accurate information about the molecular composition of the plasmas and the distribution of populations among quantum states is essential for understanding and optimizing plasma processes. Here, we apply a mid-infrared frequency comb-base…
▽ More
Non-thermal molecular plasmas play a crucial role in numerous industrial processes and hold significant potential for driving essential chemical transformations. Accurate information about the molecular composition of the plasmas and the distribution of populations among quantum states is essential for understanding and optimizing plasma processes. Here, we apply a mid-infrared frequency comb-based Fourier transform spectrometer to measure high-resolution spectra of plasmas containing hydrogen, nitrogen, and a carbon source in the 2800 - 3400 cm$^{-1}$ range. The spectrally broadband and high-resolution capabilities of this technique enable quantum-state-resolved spectroscopy of multiple plasma-generated species simultaneously, including CH$_4$, C$_2$H$_2$, C$_2$H$_6$, NH$_3$, and HCN, providing detailed information beyond the limitations of current methods. Using a line-by-line fitting approach, we analyzed 548 resolved transitions across five vibrational bands of plasma-generated HCN. The results indicate a significant non-thermal distribution of the populations among the quantum states, with distinct temperatures observed for lower and higher rotational quantum numbers, with a temperature difference of about 62 K. Broadband state-resolved-spectroscopy via comb-based methods provides unprecedented fundamental insights into the non-thermal nature of molecular plasmas - a detailed picture that has never been accomplished before for such complex non-thermal environment.
△ Less
Submitted 22 March, 2024;
originally announced March 2024.
-
Dual-comb Spectroscopy of Ammonia Formation in Non-thermal Plasmas
Authors:
Ibrahim Sadiek,
Adam J. Fleisher,
Jakob Hayden,
Xinyi Huang,
Andreas Hugi,
Richard Engeln,
Norbert Lang,
Jean-Pierre H. van Helden
Abstract:
Plasma-activated chemical transformations promise the efficient synthesis of salient chemical products. However, the reaction pathways that lead to desirable products are often unknown, and key quantum-state-resolved information regarding the involved molecular species is lacking. Here we use quantum cascade laser dual-comb spectroscopy (QCL-DCS) to probe plasma-activated NH$_3$ generation with ro…
▽ More
Plasma-activated chemical transformations promise the efficient synthesis of salient chemical products. However, the reaction pathways that lead to desirable products are often unknown, and key quantum-state-resolved information regarding the involved molecular species is lacking. Here we use quantum cascade laser dual-comb spectroscopy (QCL-DCS) to probe plasma-activated NH$_3$ generation with rotational and vibrational state resolution, quantifying state-specific number densities via broadband spectral analysis. The measurements reveal unique translational, rotational and vibrational temperatures for NH$_3$ products, indicative of a highly reactive, non-thermal environment. Ultimately, we postulate on the energy transfer mechanisms that explain trends in temperatures and number densities observed for NH$_3$ generated in low-pressure nitrogen-hydrogen (N$_2$-H$_2$) plasmas.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.