Log Skeletons: A Classification Approach to Process Discovery
Authors:
H. M. W. Verbeek,
R. Medeiros de Carvalho
Abstract:
To test the effectiveness of process discovery algorithms, a Process Discovery Contest (PDC) has been set up. This PDC uses a classification approach to measure this effectiveness: The better the discovered model can classify whether or not a new trace conforms to the event log, the better the discovery algorithm is supposed to be. Unfortunately, even the state-of-the-art fully-automated discovery…
▽ More
To test the effectiveness of process discovery algorithms, a Process Discovery Contest (PDC) has been set up. This PDC uses a classification approach to measure this effectiveness: The better the discovered model can classify whether or not a new trace conforms to the event log, the better the discovery algorithm is supposed to be. Unfortunately, even the state-of-the-art fully-automated discovery algorithms score poorly on this classification. Even the best of these algorithms, the Inductive Miner, scored only 147 correct classified traces out of 200 traces on the PDC of 2017. This paper introduces the rule-based log skeleton model, which is closely related to the Declare constraint model, together with a way to classify traces using this model. This classification using log skeletons is shown to score better on the PDC of 2017 than state-of-the-art discovery algorithms: 194 out of 200. As a result, one can argue that the fully-automated algorithm to construct (or: discover) a log skeleton from an event log outperforms existing state-of-the-art fully-automated discovery algorithms.
△ Less
Submitted 21 June, 2018;
originally announced June 2018.
Microemulsification: An Approach for Analytical Determinations
Authors:
Renato S. Lima,
Leandro Y. Shiroma,
Alvaro V. N. C. Teixeira,
José R. de Toledo,
Bruno C. do Couto,
Rogério M. de Carvalho,
Emanuel Carrilho,
Lauro T. Kubota,
Angelo L. Gobbi
Abstract:
We address a novel method for analytical determinations that combines simplicity, rapidity, low consumption of chemicals, and portability with high analytical performance taking into account parameters such as precision, linearity, robustness, and accuracy. This approach relies on the effect of the analyte content over the Gibbs free energy of dispersions, affecting the thermodynamic stabilization…
▽ More
We address a novel method for analytical determinations that combines simplicity, rapidity, low consumption of chemicals, and portability with high analytical performance taking into account parameters such as precision, linearity, robustness, and accuracy. This approach relies on the effect of the analyte content over the Gibbs free energy of dispersions, affecting the thermodynamic stabilization of emulsions or Winsor systems to form microemulsions (MEs). Such phenomenon was expressed by the minimum volume fraction of amphiphile required to form microemulsion, which was the analytical signal of the method. The performed studies were: phase behavior, droplet dimension by dynamic light scattering, analytical curve, and robustness tests. The reliability of the method was evaluated by determining water in ethanol fuels and monoethylene glycol in complex samples of liquefied natural gas. The dispersions were composed of water-chlorobenzene (water analysis) and water-oleic acid (monoethylene glycol analysis) with ethanol as the hydrotrope phase. The experiments to determine water demonstrated that the analytical performance depends on the composition of ME. The linear range was fairly broad with limits of linearity up to 70.00% water in ethanol. For monoethylene glycol in water the linear range was observed throughout the volume fraction of analyte. The natural gas samples provided by the Petrobras exhibited color, particulate material, high ionic strength, and diverse compounds as metals, carboxylic acids, and anions. The method allowed accurate measures bypassing steps such as extraction, preconcentration, and dilution of the sample. In addition, the levels of robustness were promising. This parameter was evaluated by investigating the effect of (i) deviations in volumetric preparation of the dispersions and (ii) changes in temperature over the analyte contents recorded by the method.
△ Less
Submitted 8 September, 2014;
originally announced September 2014.