-
Automated pulse discrimination of two freely-swimming weakly electric fish and analysis of their electrical behavior during a dominance contest
Authors:
Rafael Tuma Guariento,
Thiago Schiavo Mosqueiro,
Paulo Matias,
Vinicius Burani Cesarino,
Lirio Onofre Baptista de Almeida,
Jan Frans Willem Slaets,
Leonardo Paulo Maia,
Reynaldo Daniel Pinto
Abstract:
Electric fishes modulate their electric organ discharges with a remarkable variability. Some patterns can be easily identified, such as pulse rate changes, offs and chirps, which are often associated with important behavioral contexts, including aggression, hiding and mating. However, these behaviors are only observed when at least two fish are freely interacting. Although their electrical pulses…
▽ More
Electric fishes modulate their electric organ discharges with a remarkable variability. Some patterns can be easily identified, such as pulse rate changes, offs and chirps, which are often associated with important behavioral contexts, including aggression, hiding and mating. However, these behaviors are only observed when at least two fish are freely interacting. Although their electrical pulses can be easily recorded by non-invasive techniques, discriminating the emitter of each pulse is challenging when physically similar fish are allowed to freely move and interact. Here we optimized a custom-made software recently designed to identify the emitter of pulses by using automated chirp detection, adaptive threshold for pulse detection and slightly changing how the recorded signals are integrated. With these optimizations, we performed a quantitative analysis of the statistical changes throughout the dominance contest with respect to Inter Pulse Intervals, Chirps and Offs dyads of freely moving Gymnotus carapo. In all dyads, chirps were signatures of subsequent submission, even when they occurred early in the contest. Although offs were observed in both dominant and submissive fish, they were substantially more frequent in submissive individuals, in agreement with the idea from previous studies that offs are electric cues of submission. In general, after the dominance is established the submissive fish significantly changes its average pulse rate, while the pulse rate of the dominant remained unchanged. Additionally, no chirps or offs were observed when two fish were manually kept in direct physical contact, suggesting that these electric behaviors are not automatic responses to physical contact.
△ Less
Submitted 22 March, 2017; v1 submitted 1 July, 2016;
originally announced July 2016.
-
Modular Acquisition and Stimulation System for Timestamp-Driven Neuroscience Experiments
Authors:
Paulo Matias,
Rafael Tuma Guariento,
Lirio Onofre Baptista de Almeida,
Jan Frans Willem Slaets
Abstract:
Dedicated systems are fundamental for neuroscience experimental protocols that require timing determinism and synchronous stimuli generation. We developed a data acquisition and stimuli generator system for neuroscience research, optimized for recording timestamps from up to 6 spiking neurons and entirely specified in a high-level Hardware Description Language (HDL). Despite the logic complexity p…
▽ More
Dedicated systems are fundamental for neuroscience experimental protocols that require timing determinism and synchronous stimuli generation. We developed a data acquisition and stimuli generator system for neuroscience research, optimized for recording timestamps from up to 6 spiking neurons and entirely specified in a high-level Hardware Description Language (HDL). Despite the logic complexity penalty of synthesizing from such a language, it was possible to implement our design in a low-cost small reconfigurable device. Under a modular framework, we explored two different memory arbitration schemes for our system, evaluating both their logic element usage and resilience to input activity bursts. One of them was designed with a decoupled and latency insensitive approach, allowing for easier code reuse, while the other adopted a centralized scheme, constructed specifically for our application. The usage of a high-level HDL allowed straightforward and stepwise code modifications to transform one architecture into the other. The achieved modularity is very useful for rapidly prototyping novel electronic instrumentation systems tailored to scientific research.
△ Less
Submitted 7 April, 2015;
originally announced April 2015.
-
An embedded system for real-time feedback neuroscience experiments
Authors:
Lirio Onofre Baptista de Almeida,
Paulo Matias,
Rafael Tuma Guariento
Abstract:
A complete data acquisition and signal output control system for synchronous stimuli generation, geared towards in vivo neuroscience experiments, was developed using the Terasic DE2i-150 board. All emotions and thoughts are an emergent property of the chemical and electrical activity of neurons. Most of these cells are regarded as excitable cells (spiking neurons), which produce temporally localiz…
▽ More
A complete data acquisition and signal output control system for synchronous stimuli generation, geared towards in vivo neuroscience experiments, was developed using the Terasic DE2i-150 board. All emotions and thoughts are an emergent property of the chemical and electrical activity of neurons. Most of these cells are regarded as excitable cells (spiking neurons), which produce temporally localized electric patterns (spikes). Researchers usually consider that only the instant of occurrence (timestamp) of these spikes encodes information. Registering neural activity evoked by stimuli demands timing determinism and data storage capabilities that cannot be met without dedicated hardware and a hard real-time operational system (RTOS). Indeed, research in neuroscience usually requires dedicated electronic instrumentation for studies in neural coding, brain machine interfaces and closed loop in vivo or in vitro experiments. We developed a complete embedded system solution consisting of a hardware/software co-design with the Intel Atom processor running a free RTOS and a FPGA communicating via a PCIe-to-Avalon bridge. Our system is capable of registering input event timestamps with 1μs precision and digitally generating stimuli output in hard real-time. The whole system is controlled by a Linux-based Graphical User Interface (GUI). Collected results are simultaneously saved in a local file and broadcasted wirelessly to mobile device web-browsers in an user-friendly graphic format, enhanced by HTML5 technology. The developed system is low-cost and highly configurable, enabling various neuroscience experimental setups, while the commercial off-the-shelf systems have low availability and are less flexible to adapt to specific experimental configurations.
△ Less
Submitted 3 April, 2015;
originally announced April 2015.