-
$β$-nuclear-recoil correlation from $^6$He decay in a laser trap
Authors:
P. Müller,
Y. Bagdasarova,
R. Hong,
A. Leredde,
K. G. Bailey,
X. Fléchard,
A. García,
B. Graner,
A. Knecht,
O. Naviliat-Cuncic,
T. P. O'Connor,
M. G. Sternberg,
D. W. Storm,
H. E. Swanson,
F. Wauters,
D. W. Zumwalt
Abstract:
We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for…
▽ More
We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for left-handed neutrinos the limits are $0.007< C_T/C_A <0.111$~(90\%\ C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the micro-channel plate used for recoil ion detection.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
High accuracy position response calibration method for a micro-channel plate ion detector
Authors:
Ran Hong,
Arnaud Leredde,
Yelena Bagdasarova,
Xavier Flechard,
Alejandro Garcia,
Peter Mueller,
Andreas Knecht,
Etienne Lienard,
Michael Kossin,
Matthew G. Sternberg,
H. E. Swanson,
David W. Zumwalt
Abstract:
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position r…
▽ More
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position responses to high-energy $α$ particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear $β$-decay experiment.
△ Less
Submitted 8 September, 2016; v1 submitted 27 May, 2016;
originally announced May 2016.
-
Weak Interaction Studies with 6He
Authors:
A. Knecht,
Z. T. Alexander,
Y. Bagdasarova,
T. M. Cope,
B. G. Delbridge,
X. Flechard,
A. Garcia,
R. Hong,
E. Lienard,
P. Mueller,
O. Naviliat-Cuncic,
A. S. C. Palmer,
R. G. H. Robertson,
D. W. Storm,
H. E. Swanson,
S. Utsuno,
F. Wauters,
W. Williams,
C. Wrede,
D. W. Zumwalt
Abstract:
The 6He nucleus is an ideal candidate to study the weak interaction. To this end we have built a high-intensity source of 6He delivering ~10^10 atoms/s to experiments. Taking full advantage of that available intensity we have performed a high-precision measurement of the 6He half-life that directly probes the axial part of the nuclear Hamiltonian. Currently, we are preparing a measurement of the b…
▽ More
The 6He nucleus is an ideal candidate to study the weak interaction. To this end we have built a high-intensity source of 6He delivering ~10^10 atoms/s to experiments. Taking full advantage of that available intensity we have performed a high-precision measurement of the 6He half-life that directly probes the axial part of the nuclear Hamiltonian. Currently, we are preparing a measurement of the beta-neutrino angular correlation in 6He beta decay that will allow to search for new physics beyond the Standard Model in the form of tensor currents.
△ Less
Submitted 19 October, 2012; v1 submitted 31 August, 2012;
originally announced August 2012.
-
Precision Measurement of the 6He Half-Life and the Weak Axial Current in Nuclei
Authors:
A. Knecht,
R. Hong,
D. W. Zumwalt,
B. G. Delbridge,
A. Garcia,
P. Mueller,
H. E. Swanson,
I. S. Towner,
S. Utsuno,
W. Williams,
C. Wrede
Abstract:
Studies of 6He beta decay along with tritium can play an important role in testing ab-initio nuclear wave-function calculations and may allow for fixing low-energy constants in effective field theories. Here, we present an improved determination of the 6He half-life to a relative precision of 3x10^(-4). Our value of 806.89 \pm 0.11(stat)^{+0.23}_{-0.19}(syst) ms resolves a major discrepancy betwee…
▽ More
Studies of 6He beta decay along with tritium can play an important role in testing ab-initio nuclear wave-function calculations and may allow for fixing low-energy constants in effective field theories. Here, we present an improved determination of the 6He half-life to a relative precision of 3x10^(-4). Our value of 806.89 \pm 0.11(stat)^{+0.23}_{-0.19}(syst) ms resolves a major discrepancy between previous measurements. Calculating the statistical rate function we determined the ft-value to be 803.04 ^{+0.26}_{-0.23} s. The extracted Gamow-Teller matrix element agrees within a few percent with ab-initio calculations.
△ Less
Submitted 23 March, 2012; v1 submitted 25 October, 2011;
originally announced October 2011.