-
Reducing the Dynamic State Index to its main information using Principal Component Analysis
Authors:
Annette Müller,
Nikolai Spaeth,
Johanna Bollow,
Iris Eder,
Alina Fischer,
Jana Frenzel,
Annika Görnt,
Kunyan Hao,
Johanne Ilchmann,
Isabel Kasner,
Corinna Langwald,
Steffen Laube,
Flavio Maggioni,
Beatrice Neiszt-Pllana,
Daniel A. Redant,
Lisa Rogge,
Sus Sama,
David Scheer,
Inga Spreen,
Patrick W. Varchmin,
Vanessa R. Zabel,
Wei Zhang,
Anika Zibell
Abstract:
The Dynamic State Index is a scalar quantity designed to identify atmospheric developments such as fronts, hurricanes or specific weather pattern. The DSI is defined as Jacobian-determinant of three constitutive quantities that characterize three-dimensional fluid flows: the Bernoulli stream function, the potential vorticity (PV) and the potential temperature. Here, we tackle the questions (i) if…
▽ More
The Dynamic State Index is a scalar quantity designed to identify atmospheric developments such as fronts, hurricanes or specific weather pattern. The DSI is defined as Jacobian-determinant of three constitutive quantities that characterize three-dimensional fluid flows: the Bernoulli stream function, the potential vorticity (PV) and the potential temperature. Here, we tackle the questions (i) if the mathematical formulation of the DSI can be reduced, while keeping the main information, and (ii) does the reduction of the DSI depend on the spatial scale? Applying principle component analysis we find that three of six DSI terms that sum up to the Jacobi-determinant are sufficient for future DSI calculations.
△ Less
Submitted 6 March, 2022;
originally announced March 2022.
-
Development of Fast High-Resolution Muon Drift-Tube Detectors for High Counting Rates
Authors:
B. Bittner,
J. Dubbert,
S. Horvat,
O. Kortner,
H. Kroha,
F. Legger,
R. Richter,
S. Adomeit,
O. Biebel,
A. Engl,
R. Hertenberger,
F. Rauscher,
A. Zibell
Abstract:
Pressurized drift-tube chambers are efficient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial resolution of 35 micons and almost 100% tracking efficiency with 6 layers of 30 mm diameter drift tubes operated with Ar:CO2 (93:7) gas mixture at 3 bar and a g…
▽ More
Pressurized drift-tube chambers are efficient detectors for high-precision tracking over large areas. The Monitored Drift-Tube (MDT) chambers of the muon spectrometer of the ATLAS detector at the Large Hadron Collider (LHC) reach a spatial resolution of 35 micons and almost 100% tracking efficiency with 6 layers of 30 mm diameter drift tubes operated with Ar:CO2 (93:7) gas mixture at 3 bar and a gas gain of 20000. The ATLAS MDT chambers are designed to cope with background counting rates due to neutrons and gamma-rays of up to about 300 kHz per tube which will be exceeded for LHC luminosities larger than the design value of 10-34 per square cm and second. Decreasing the drift-tube diameter to 15 mm while keeping the other parameters, including the gas gain, unchanged reduces the maximum drift time from about 700 ns to 200 ns and the drift-tube occupancy by a factor of 7. New drift-tube chambers for the endcap regions of the ATLAS muon spectrometer have been designed. A prototype chamber consisting of 12 times 8 layers of 15 mm diameter drift tubes of 1 m length has been constructed with a sense wire positioning accuracy of 20 microns. The 15 mm diameter drift-tubes have been tested with cosmic rays in the Gamma Irradiation Facility at CERN at counting rates of up to 1.85 MHz.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades
Authors:
Bernhard Bittner,
Joerg Dubbert,
Oliver Kortner,
Hubert Kroha,
Alessandro Manfredini,
Sebastian Nowak,
Sebastian Ott,
Robert Richter,
Philipp Schwegler,
Daniele Zanzi,
Otmar Biebel,
Ralf Hertenberger,
Alexander Ruschke,
Andre Zibell
Abstract:
The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm…
▽ More
The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking efficiency and spatial resolution at high counting rates will be achieved with upgraded readout electronics employing improved signal shaping for high counting rates.
△ Less
Submitted 31 March, 2016;
originally announced March 2016.
-
High-Rate Capable Floating Strip Micromegas
Authors:
Jonathan Bortfeldt,
Michael Bender,
Otmar Biebel,
Helge Danger,
Bernhard Flierl,
Ralf Hertenberger,
Philipp Lösel,
Samuel Moll,
Katia Parodi,
Ilaria Rinaldi,
Alexander Ruschke,
André Zibell
Abstract:
We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm$^2$. Measurement and simulation of the microscopic discharge behavior have demonstrated the ex…
▽ More
We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm$^2$. Measurement and simulation of the microscopic discharge behavior have demonstrated the excellent discharge tolerance. A floating strip Micromegas with an active area of 48cm$\times$50cm with 1920 copper anode strips exhibits in 120GeV pion beams a spatial resolution of 50$μ$m at detection efficiencies above 95%. Pulse height, spatial resolution and detection efficiency are homogeneous over the detector. Reconstruction of particle track inclination in a single detector plane is discussed, optimum angular resolutions below $5^\circ$ are observed. Systematic deviations of this $μ$TPC-method are fully understood. The reconstruction capabilities for minimum ionizing muons are investigated in a 6.4cm$\times$6.4cm floating strip Micromegas under intense background irradiation of the whole active area with 20MeV protons at a rate of 550kHz. The spatial resolution for muons is not distorted by space charge effects. A 6.4cm$\times$6.4cm floating strip Micromegas doublet with low material budget is investigated in highly ionizing proton and carbon ion beams at particle rates between 2MHz and 2GHz. Stable operation up to the highest rates is observed, spatial resolution, detection efficiencies, the multi-hit and high-rate capability are discussed.
△ Less
Submitted 4 August, 2015;
originally announced August 2015.
-
High Rate Proton Irradiation of 15mm Muon Drifttubes
Authors:
Andre Zibell,
Otmar Biebel,
Ralf Hertenberger,
Alexander Ruschke,
Christopher Schmitt,
Hubert Kroha,
Bernhard Bittner,
Philipp Schwegler,
Jörg Dubbert,
Sebastian Ott
Abstract:
Future LHC luminosity upgrades will significantly increase the amount of background hits from photons, neutrons and protons in the detectors of the ATLAS muon spectrometer. At the proposed LHC peak luminosity of 5*10^34 1/cm^2s, background hit rates of more than 10 kHz/cm^2 are expected in the innermost forward region, leading to a loss of performance of the current tracking chambers. Based on the…
▽ More
Future LHC luminosity upgrades will significantly increase the amount of background hits from photons, neutrons and protons in the detectors of the ATLAS muon spectrometer. At the proposed LHC peak luminosity of 5*10^34 1/cm^2s, background hit rates of more than 10 kHz/cm^2 are expected in the innermost forward region, leading to a loss of performance of the current tracking chambers. Based on the ATLAS Monitored Drift Tube chambers, a new high rate capable drift tube detecor using tubes with a reduced diameter of 15mm was developed. To test the response to highly ionizing particles, a prototype chamber of 46 15mm drift tubes was irradiated with a 20 MeV proton beam at the tandem accelerator at the Maier-Leibnitz Laboratory, Munich. Three tubes in a planar layer were irradiated while all other tubes were used for reconstruction of cosmic muon tracks through irradiated and non-irradiated parts of the chamber. To determine the rate capability of the 15mm drift-tubes we investigated the effect of the proton hit rate on pulse height, efficiency and spatial resolution of the cosmic muon signals.
△ Less
Submitted 13 March, 2012;
originally announced March 2012.