Deep Learning-based Assessment of Hepatic Steatosis on chest CT
Authors:
Zhongyi Zhang,
Jakob Weiss,
Jana Taron,
Roman Zeleznik,
Michael T. Lu,
Hugo J. W. L. Aerts
Abstract:
Purpose: Automatic methods are required for the early detection of hepatic steatosis to avoid progression to cirrhosis and cancer. Here, we developed a fully automated deep learning pipeline to quantify hepatic steatosis on non-contrast enhanced chest computed tomography (CT) scans. Materials and Methods: We developed and evaluated our pipeline on chest CT images of 1,431 randomly selected Nationa…
▽ More
Purpose: Automatic methods are required for the early detection of hepatic steatosis to avoid progression to cirrhosis and cancer. Here, we developed a fully automated deep learning pipeline to quantify hepatic steatosis on non-contrast enhanced chest computed tomography (CT) scans. Materials and Methods: We developed and evaluated our pipeline on chest CT images of 1,431 randomly selected National Lung Screening Trial (NLST) participants. A dataset of 451 CT scans with volumetric liver segmentations of expert readers was used for training a deep learning model. For testing, in an independent dataset of 980 CT scans hepatic attenuation was manually measured by an expert reader on three cross-sectional images at different hepatic levels by selecting three circular regions of interest. Additionally, 100 randomly selected cases of the test set were volumetrically segmented by expert readers. Hepatic steatosis on the test set was defined as mean hepatic attenuation of < 40 Hounsfield unit. Spearman correlation was conducted to analyze liver fat quantification accuracy and the Cohen's Kappa coefficient was calculated for hepatic steatosis prediction reliability. Results: Our pipeline demonstrated strong performance and achieved a mean dice score of 0.970 for the volumetric liver segmentation. The spearman correlation of the liver fat quantification was 0.954 (P <0.0001) between the automated and expert reader measurements. The cohen's kappa coefficient was 0.875 for automatic assessment of hepatic steatosis. Conclusion: We developed a fully automatic deep learning-based pipeline for the assessment of hepatic steatosis in chest CT images. With the fast and cheap screening of hepatic steatosis, our pipeline has the potential to help initiate preventive measures to avoid progression to cirrhosis and cancer.
△ Less
Submitted 4 February, 2022;
originally announced February 2022.
Deep learning-based detection of intravenous contrast in computed tomography scans
Authors:
Zezhong Ye,
Jack M. Qian,
Ahmed Hosny,
Roman Zeleznik,
Deborah Plana,
Jirapat Likitlersuang,
Zhongyi Zhang,
Raymond H. Mak,
Hugo J. W. L. Aerts,
Benjamin H. Kann
Abstract:
Purpose: Identifying intravenous (IV) contrast use within CT scans is a key component of data curation for model development and testing. Currently, IV contrast is poorly documented in imaging metadata and necessitates manual correction and annotation by clinician experts, presenting a major barrier to imaging analyses and algorithm deployment. We sought to develop and validate a convolutional neu…
▽ More
Purpose: Identifying intravenous (IV) contrast use within CT scans is a key component of data curation for model development and testing. Currently, IV contrast is poorly documented in imaging metadata and necessitates manual correction and annotation by clinician experts, presenting a major barrier to imaging analyses and algorithm deployment. We sought to develop and validate a convolutional neural network (CNN)-based deep learning (DL) platform to identify IV contrast within CT scans. Methods: For model development and evaluation, we used independent datasets of CT scans of head, neck (HN) and lung cancer patients, totaling 133,480 axial 2D scan slices from 1,979 CT scans manually annotated for contrast presence by clinical experts. Five different DL models were adopted and trained in HN training datasets for slice-level contrast detection. Model performances were evaluated on a hold-out set and on an independent validation set from another institution. DL models was then fine-tuned on chest CT data and externally validated on a separate chest CT dataset. Results: Initial DICOM metadata tags for IV contrast were missing or erroneous in 1,496 scans (75.6%). The EfficientNetB4-based model showed the best overall detection performance. For HN scans, AUC was 0.996 in the internal validation set (n = 216) and 1.0 in the external validation set (n = 595). The fine-tuned model on chest CTs yielded an AUC: 1.0 for the internal validation set (n = 53), and AUC: 0.980 for the external validation set (n = 402). Conclusion: The DL model could accurately detect IV contrast in both HN and chest CT scans with near-perfect performance.
△ Less
Submitted 19 October, 2021; v1 submitted 15 October, 2021;
originally announced October 2021.