-
LET measurements and simulation modelling of the charged particle field for the Clatterbridge ocular proton therapy beamline
Authors:
Jacinta S. L. Yap,
Navrit J. S. Bal,
Mark D. Brooke,
Cristina Oancea,
Carlos Granja,
Andrzej Kacperek,
Simon Jolly,
Frank Van den Heuvel,
Jason L. Parsons,
Carsten P. Welsch
Abstract:
Proton therapy can achieve a highly targeted treatment by utilising the advantageous dosimetric characteristics of the Bragg Peak. Protons traversing through a material will deposit their maximum energy at the Bragg Peak through ionisation and other interactions, transferring minimal excess dose to surrounding tissue and organs. This rate of energy loss is also quantified by the linear energy tran…
▽ More
Proton therapy can achieve a highly targeted treatment by utilising the advantageous dosimetric characteristics of the Bragg Peak. Protons traversing through a material will deposit their maximum energy at the Bragg Peak through ionisation and other interactions, transferring minimal excess dose to surrounding tissue and organs. This rate of energy loss is also quantified by the linear energy transfer (LET), which is indicative of radiation quality and radiobiological effects. However it is a challenging physical quantity to measure, as characterisation of radiation fields and the impact of LET on treatment requires advanced tools and technology. The MiniPIX-Timepix is a miniaturised, hybrid semiconductor pixel detector capable of high resolution spectrometric tracking, enabling wide-range detection of the deposited energy, position and direction of single particles. Experimental measurements were performed at a clinical facility, the Clatterbridge Cancer Centre which houses a 60 MeV ocular proton therapy beamline. A realistic end-to-end model of the facility was developed in the Monte Carlo code TOPAS (TOol for PArticle Simulation) and was used to simulate the experimental conditions. The detector was held at 45$^{\circ}$ and 60$^{\circ}$ perpendicular to the beam, and placed downstream of various thickness Polymethyl methacrylate (PMMA) blocks to acquire data along the dose deposition depth. Empirical cluster data providing track length and the energy deposition distributions were used to obtain the LET spectra. The determined values for the LET in silicon and dose averaged LET across the BP show general agreement with simulated results, supporting the applicability of the TOPAS CCC model. This work explores the capability of the MiniPIX detector to measure physical quantities to resolve the LET, and discusses experimental considerations and further possibilities.
△ Less
Submitted 30 January, 2025; v1 submitted 28 January, 2025;
originally announced January 2025.
-
Design of a large energy acceptance beamline using Fixed Field Accelerator optics
Authors:
A. F. Steinberg,
R. B. Appleby,
J. S. L. Yap,
Suzie Sheehy
Abstract:
Large energy acceptance arcs have been proposed for applications such as cancer therapy, muon accelerators, and recirculating linacs. The efficacy of charged particle therapy can be improved by reducing the energy layer switching time, however this is currently limited by the small momentum acceptance of the beam delivery system ($<\pm$1\%). A `closed-dispersion arc' with a large momentum acceptan…
▽ More
Large energy acceptance arcs have been proposed for applications such as cancer therapy, muon accelerators, and recirculating linacs. The efficacy of charged particle therapy can be improved by reducing the energy layer switching time, however this is currently limited by the small momentum acceptance of the beam delivery system ($<\pm$1\%). A `closed-dispersion arc' with a large momentum acceptance has the potential to remove this bottleneck, however such a beamline has not yet been constructed. We have developed a design methodology for large momentum acceptance arcs with Fixed Field Accelerator optics, applying it to a demonstrator beam delivery system for protons at 0.5--3.0MeV $\pm$42\% momentum acceptance) as part of the TURBO project at the University of Melbourne. Using realistic magnetic fields, a beamline has been designed with zero dispersion at either end. An algorithm has been devised for the construction of permanent magnet Halbach arrays for this beamline with multipole error below one part in $10^4$, using commercially available magnets. The sensitivity to errors has been investigated, finding that the delivered beam is robust in realistic conditions. This study demonstrates that a closed-dispersion arc with fixed fields can achieve a large momentum acceptance, and we outline future work required to develop these ideas into a complete proof-of-principle beam delivery system that can be scaled up for a medical facility.
△ Less
Submitted 1 February, 2024;
originally announced February 2024.
-
Medipix3 for dosimetry and real-time beam monitoring: first tests at a 60 MeV proton therapy facility
Authors:
J. S. L. Yap,
N. J. S. Bal,
A. Kacperek,
J. Resta López,
C. P. Welsch
Abstract:
Charged particle therapy (CPT) is an advanced modality of radiation therapy which has grown rapidly worldwide, driven by recent developments in technology and methods of delivery. To ensure safe and high quality treatments, various instruments are used for a range of different measurements such as for quality assurance, monitoring and dosimetry purposes. With the emergence of new and enhanced deli…
▽ More
Charged particle therapy (CPT) is an advanced modality of radiation therapy which has grown rapidly worldwide, driven by recent developments in technology and methods of delivery. To ensure safe and high quality treatments, various instruments are used for a range of different measurements such as for quality assurance, monitoring and dosimetry purposes. With the emergence of new and enhanced delivery techniques, systems with improved capabilities are needed to exceed existing performance limitations of conventional tools. The Medipix3 is a hybrid pixel detector able to count individual protons with millisecond time resolution at clinical flux with near instant readout and count rate linearity. The system has previously demonstrated use in medical and other applications, showing wide versatility and potential for particle therapy. In this work we present measurements of the Medipix3 detector in the 60 MeV ocular proton therapy beamline at the Clatterbridge Cancer Centre, UK. The beam current and lateral beam profiles were evaluated at multiple positions in the treatment line and compared with EBT3 Gafchromic film. The recorded count rate linearity and temporal analysis of the beam structure was measured with Medipix3 across the full range of available beam intensities, up to $3.12 \times 10^{10}$ protons/s. We explore the capacity of Medipix3 to provide non-reference measurements and its applicability as a tool for dosimetry and beam monitoring for CPT. This is the first known time the performance of the Medipix3 detector technology has been tested within a clinical, high proton flux environment.
△ Less
Submitted 15 September, 2021; v1 submitted 5 July, 2021;
originally announced July 2021.