-
In Search of Patient Zero: Visual Analytics of Pathogen Transmission Pathways in Hospitals
Authors:
T. Baumgartl,
M. Petzold,
M. Wunderlich,
M. Höhn,
D. Archambault,
M. Lieser,
A. Dalpke,
S. Scheithauer,
M. Marschollek,
V. M. Eichel,
N. T. Mutters,
HiGHmed Consortium,
T. von Landesberger
Abstract:
Pathogen outbreaks (i.e., outbreaks of bacteria and viruses) in hospitals can cause high mortality rates and increase costs for hospitals significantly. An outbreak is generally noticed when the number of infected patients rises above an endemic level or the usual prevalence of a pathogen in a defined population. Reconstructing transmission pathways back to the source of an outbreak -- the patient…
▽ More
Pathogen outbreaks (i.e., outbreaks of bacteria and viruses) in hospitals can cause high mortality rates and increase costs for hospitals significantly. An outbreak is generally noticed when the number of infected patients rises above an endemic level or the usual prevalence of a pathogen in a defined population. Reconstructing transmission pathways back to the source of an outbreak -- the patient zero or index patient -- requires the analysis of microbiological data and patient contacts. This is often manually completed by infection control experts. We present a novel visual analytics approach to support the analysis of transmission pathways, patient contacts, the progression of the outbreak, and patient timelines during hospitalization. Infection control experts applied our solution to a real outbreak of Klebsiella pneumoniae in a large German hospital. Using our system, our experts were able to scale the analysis of transmission pathways to longer time intervals (i.e., several years of data instead of days) and across a larger number of wards. Also, the system is able to reduce the analysis time from days to hours. In our final study, feedback from twenty-five experts from seven German hospitals provides evidence that our solution brings significant benefits for analyzing outbreaks. It is also applicable to COVID-19 hospital-associated transmissions.
△ Less
Submitted 21 September, 2020; v1 submitted 21 August, 2020;
originally announced August 2020.
-
First 230 GHz VLBI Fringes on 3C 279 using the APEX Telescope
Authors:
J. Wagner,
A. L. Roy,
T. P. Krichbaum,
W. Alef,
A. Bansod,
A. Bertarini,
R. Güsten,
D. Graham,
J. Hodgson,
R. Märtens,
K. Menten,
D. Muders,
H. Rottmann,
G. Tuccari,
A. Weiss,
G. Wieching,
M. Wunderlich,
J. A. Zensus,
J. P. Araneda,
O. Arriagada,
M. Cantzler,
C. Duran,
F. M. Montenegro-Montes,
R. Olivares,
P. Caro
, et al. (30 additional authors not shown)
Abstract:
We report about a 230 GHz very long baseline interferometry (VLBI) fringe finder observation of blazar 3C 279 with the APEX telescope in Chile, the phased submillimeter array (SMA), and the SMT of the Arizona Radio Observatory (ARO). We installed VLBI equipment and measured the APEX station position to 1 cm accuracy (1 sigma). We then observed 3C 279 on 2012 May 7 in a 5 hour 230 GHz VLBI track wi…
▽ More
We report about a 230 GHz very long baseline interferometry (VLBI) fringe finder observation of blazar 3C 279 with the APEX telescope in Chile, the phased submillimeter array (SMA), and the SMT of the Arizona Radio Observatory (ARO). We installed VLBI equipment and measured the APEX station position to 1 cm accuracy (1 sigma). We then observed 3C 279 on 2012 May 7 in a 5 hour 230 GHz VLBI track with baseline lengths of 2800 M$λ$ to 7200 M$λ$ and a finest fringe spacing of 28.6 micro-arcseconds. Fringes were detected on all baselines with SNRs of 12 to 55 in 420 s. The correlated flux density on the longest baseline was ~0.3 Jy/beam, out of a total flux density of 19.8 Jy. Visibility data suggest an emission region <38 uas in size, and at least two components, possibly polarized. We find a lower limit of the brightness temperature of the inner jet region of about 10^10 K. Lastly, we find an upper limit of 20% on the linear polarization fraction at a fringe spacing of ~38 uas. With APEX the angular resolution of 230 GHz VLBI improves to 28.6 uas. This allows one to resolve the last-photon ring around the Galactic Center black hole event horizon, expected to be 40 uas in diameter, and probe radio jet launching at unprecedented resolution, down to a few gravitational radii in galaxies like M 87. To probe the structure in the inner parsecs of 3C 279 in detail, follow-up observations with APEX and five other mm-VLBI stations have been conducted (March 2013) and are being analyzed.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Metamaterials proposed as perfect magnetoelectrics
Authors:
A. M. Shuvaev,
S. Engelbrecht,
M. Wunderlich,
A. Schneider,
A. Pimenov
Abstract:
Magnetoelectric susceptibility of a metamaterial built from split ring resonators have been investigated both experimentally and within an equivalent circuit model. The absolute values have been shown to exceed by two orders of magnitude that of classical magnetoelectric materials. The metamaterial investigated reaches the theoretically predicted value of the magnetoelectric susceptibility which i…
▽ More
Magnetoelectric susceptibility of a metamaterial built from split ring resonators have been investigated both experimentally and within an equivalent circuit model. The absolute values have been shown to exceed by two orders of magnitude that of classical magnetoelectric materials. The metamaterial investigated reaches the theoretically predicted value of the magnetoelectric susceptibility which is equal to the geometric average of the electric and magnetic susceptibilities.
△ Less
Submitted 26 April, 2010;
originally announced April 2010.