First Limits on Light Dark Matter Interactions in a Low Threshold Two Channel Athermal Phonon Detector from the TESSERACT Collaboration
Authors:
C. L. Chang,
Y. -Y. Chang,
L. Chaplinsky,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
X. Li,
J. Lin,
M. Lisovenko,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
V. Novati,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
M. Pyle,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani,
B. Sadoulet,
B. Serfass
, et al. (23 additional authors not shown)
Abstract:
We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g…
▽ More
We present results of a search for spin-independent dark matter-nucleon interactions in a 1 cm$^2$ by 1 mm thick (0.233 gram) high-resolution silicon athermal phonon detector operated above ground. For interactions in the substrate, this detector achieves a r.m.s. baseline energy resolution of 361.5 $\pm$ 0.4 MeV/$c^2$, the best for any athermal phonon detector to date. With an exposure of 0.233g $\times$ 12 hours, we place the most stringent constraints on dark matter masses between 44 and 87 MeV/$c^2$, with the lowest unexplored cross section of 4 $\times 10^{-32}$ cm$^2$ at 87 MeV/$c^2$. We employ a conservative salting technique to reach the lowest dark matter mass ever probed via direct detection experiment. This constraint is enabled by two-channel rejection of low-energy backgrounds that are coupled to individual sensors.
△ Less
Submitted 28 March, 2025; v1 submitted 5 March, 2025;
originally announced March 2025.
Design Studies Of A Pulsed Quasimonoenergetic 2-keV Neutron Source For Calibration Of Low Threshold Dark Matter Detectors
Authors:
L. Chaplinsky,
S. Fiorucci,
C. W. Fink,
M. Garcia-Sciveres,
W. Guo,
S. A. Hertel,
J. K. Wuko,
X. Li,
J. Lin,
R. Mahapatra,
W. Matava,
D. N. McKinsey,
D. Z. Osterman,
P. K. Patel,
B. Penning,
H. D. Pinckney,
M. Platt,
Y. Qi,
M. Reed,
G. R. C Rischbieter,
R. K. Romani,
P. Sorensen,
V. Velan,
G. Wang,
Y. Wang
, et al. (2 additional authors not shown)
Abstract:
We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub-GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and then filtered to the monoener…
▽ More
We describe design studies for a pulsed quasi-monoenergetic 2-keV neutron source for calibration of sub-keV nuclear recoils. Such a calibration is required for detectors sensitive to sub-GeV dark matter and also the coherent elastic scattering of reactor neutrinos. In our design, neutrons from a commercial deuterium-tritium generator are moderated to the keV scale and then filtered to the monoenergetic spectrum using a feature in the neutron cross section of scandium. In this approach, unmoderated high-energy neutrons form a challenging background, along with gammas from neutron capture in the moderator materials. We describe the optimization of the moderator+filter and shielding geometry, and find a geometry that in simulation achieves both the target neutron flux at 2 keV and subdominant rates of background interactions. Lastly, we describe a future path to lower-energy (few eV scale) calibrations using time-of-flight and sub-keV neutrons.
△ Less
Submitted 14 October, 2024;
originally announced October 2024.