-
u-RANIA: a neutron detector based on μ-RWELL technology
Authors:
I. Balossino,
G. Bencivenni,
P. Bielowka,
G. Cibinetto,
R. Farinelli,
G. Felici,
I. Garzia,
M. Gatta,
P. Giacomelli,
M. Giovannetti,
R. Hall Wilton,
C. -C. Lai,
L. Lavezzi,
F. Messi,
G. Mezzadri,
G. Morello,
M. Pinamonti,
M. Poli Lener,
L. Robinson,
M. Scodeggio,
P. -O. Svensson
Abstract:
In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL ($μ$ -RWELL) technology. The $μ$ -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The a…
▽ More
In the framework of the ATTRACT-uRANIA project, funded by the European Community, we are developing an innovative neutron imaging detector based on micro-Resistive WELL ($μ$ -RWELL) technology. The $μ$ -RWELL, based on the resistive detector concept, ensuring an efficient spark quenching mechanism, is a highly reliable device. It is composed by two main elements: a readout-PCB and a cathode. The amplification stage for this device is embedded in the readout board through a resistive layer realized by means of an industrial process with DLC (Diamond-Like Carbon). A thin layer of B$_4$C on the copper surface of the cathode allows the thermal neutrons detection through the release of $^7$Li and $α$ particles in the active volume. This technology has been developed to be an efficient and convenient alternative to the $^3$He shortage. The goal of the project is to prove the feasibility of such a novel neutron detector by developing and testing small planar prototypes with readout boards suitably segmented with strip or pad read out, equipped with existing electronics or readout in current mode. Preliminary results from the test with different prototypes, showing a good agreement with the simulation, will be presented together with construction details of the prototypes and the future steps of the project.
△ Less
Submitted 17 August, 2020; v1 submitted 13 May, 2020;
originally announced May 2020.
-
Characterization and Integration of the Singular Test Integrals in the Method-of-Moments Implementation of the Electric-Field Integral Equation
Authors:
Brian A. Freno,
William A. Johnson,
Brian F. Zinser,
Donald R. Wilton,
Francesca Vipiana,
Salvatore Campione
Abstract:
In this paper, we characterize the logarithmic singularities arising in the method of moments from the Green's function in integrals over the test domain, and we use two approaches for designing geometrically symmetric quadrature rules to integrate these singular integrands. These rules exhibit better convergence properties than quadrature rules for polynomials and, in general, lead to better accu…
▽ More
In this paper, we characterize the logarithmic singularities arising in the method of moments from the Green's function in integrals over the test domain, and we use two approaches for designing geometrically symmetric quadrature rules to integrate these singular integrands. These rules exhibit better convergence properties than quadrature rules for polynomials and, in general, lead to better accuracy with a lower number of quadrature points. We demonstrate their effectiveness for several examples encountered in both the scalar and vector potentials of the electric-field integral equation (singular, near-singular, and far interactions) as compared to the commonly employed polynomial scheme and the double Ma--Rokhlin--Wandzura (DMRW) rules, whose sample points are located asymmetrically within triangles.
△ Less
Submitted 29 December, 2020; v1 submitted 5 November, 2019;
originally announced November 2019.
-
Particle Tracking and Extended Object Imaging by Interferometric Super Resolution Microscopy
Authors:
Itay Gdor,
Seunghwan Yoo,
Xiaolei Wang,
Matthew Daddysman,
Rosemarie Wilton,
Nicola Ferrier,
Mark Hereld,
Oliver,
Cossairt,
Aggelos Katsaggelos,
Norbert F. Scherer
Abstract:
An interferometric fluorescent microscope and a novel theoretic image reconstruction approach were developed and used to obtain super-resolution images of live biological samples and to enable dynamic real time tracking. The tracking utilizes the information stored in the interference pattern of both the illuminating incoherent light and the emitted light. By periodically shifting the interferomet…
▽ More
An interferometric fluorescent microscope and a novel theoretic image reconstruction approach were developed and used to obtain super-resolution images of live biological samples and to enable dynamic real time tracking. The tracking utilizes the information stored in the interference pattern of both the illuminating incoherent light and the emitted light. By periodically shifting the interferometer phase and a phase retrieval algorithm we obtain information that allow localization with sub-2 nm axial resolution at 5 Hz.
△ Less
Submitted 14 February, 2018;
originally announced February 2018.
-
3D Snapshot Microscopy of Extended Objects
Authors:
Xiang Huang,
Alan Selewa,
Xiaolei Wang,
Matthew K. Daddysman,
Itay Gdor,
Rosemarie Wilton,
Kenneth M. Kemner,
Seunghwan Yoo,
Aggelos K. Katsaggelos,
Kuan He,
Oliver Cossairt,
Nicola J. Ferrier,
Mark Hereld,
Norbert F. Scherer
Abstract:
Volumetric biological imaging often involves compromising high temporal resolution at the expense of high spatial resolution when popular scanning methods are used to capture 3D information. We introduce an integrated experimental and image reconstruction method for capturing dynamic 3D fluorescent extended objects as a series of synchronously measured 3D snapshots taken at the frame rate of the i…
▽ More
Volumetric biological imaging often involves compromising high temporal resolution at the expense of high spatial resolution when popular scanning methods are used to capture 3D information. We introduce an integrated experimental and image reconstruction method for capturing dynamic 3D fluorescent extended objects as a series of synchronously measured 3D snapshots taken at the frame rate of the imaging camera. We employ multifocal microscopy (MFM) to simultaneously image at 25 focal planes and process this depth-encoded image to recover the 3D structure of extended objects, such as bacteria, using a sparsity-based reconstruction approach. The combined experimental and computational method produces image quality similar to confocal microscopy in a fraction of the acquisition time. In addition, our computational image reconstruction approach allows a simplified MFM optical design by correcting aberrations using the measured response to point sources. This "compressive" MFM acquisition and reconstruction method, where an image volume with roughly 8 million voxels is recovered from a single 1-megapixel captured image, enables straightforward study of dynamic processes in 3D, and as a simultaneous snapshot advances the state of the art in dynamic 3D microscopy.
△ Less
Submitted 22 May, 2018; v1 submitted 5 February, 2018;
originally announced February 2018.
-
The SMC' is a highly accurate approximation to the ancestral recombination graph
Authors:
Peter R. Wilton,
Shai Carmi,
Asger Hobolth
Abstract:
Two sequentially Markov coalescent models (SMC and SMC') are available as tractable approximations to the ancestral recombination graph (ARG). We present a Markov process describing coalescence at two fixed points along a pair of sequences evolving under the SMC'. Using our Markov process, we derive a number of new quantities related to the pairwise SMC', thereby analytically quantifying for the f…
▽ More
Two sequentially Markov coalescent models (SMC and SMC') are available as tractable approximations to the ancestral recombination graph (ARG). We present a Markov process describing coalescence at two fixed points along a pair of sequences evolving under the SMC'. Using our Markov process, we derive a number of new quantities related to the pairwise SMC', thereby analytically quantifying for the first time the similarity between the SMC' and ARG. We use our process to show that the joint distribution of pairwise coalescence times at recombination sites under the SMC' is the same as it is marginally under the ARG, which demonstrates that the SMC' is, in a particular well-defined, intuitive sense, the most appropriate first-order sequentially Markov approximation to the ARG. Finally, we use these results to show that population size estimates under the pairwise SMC are asymptotically biased, while under the pairwise SMC' they are approximately asymptotically unbiased.
△ Less
Submitted 4 March, 2015; v1 submitted 12 January, 2015;
originally announced January 2015.