-
A Comparative Evaluation of CT Global Noise Calculation Methods for Clinical Image Quality Assessment
Authors:
Charles M Weaver,
Gary Ge,
Alexander Alsalihi,
Jie Zhang
Abstract:
The CMS quality measure for CT mandates compliance with dose and image quality across 18 exam categories, yet the method for calculating global noise (GN) remains undefined, referencing only the Duke and Wisconsin methods. This ambiguity raises concerns about standardization and clinical applicability. We retrospectively analyzed 719 CT exams across seven protocols, comparing five GN metrics deriv…
▽ More
The CMS quality measure for CT mandates compliance with dose and image quality across 18 exam categories, yet the method for calculating global noise (GN) remains undefined, referencing only the Duke and Wisconsin methods. This ambiguity raises concerns about standardization and clinical applicability. We retrospectively analyzed 719 CT exams across seven protocols, comparing five GN metrics derived from the Duke and Wisconsin approaches. Results showed significant variability across metrics and protocols, with Wisconsin_tissue_mean consistently yielding the highest values. Correlation strength varied by protocol, and mode-based metrics demonstrated higher agreement, suggesting dose dependence. In the Chest PE protocol, GN values differed significantly based on reconstruction kernel. These findings underscore the need for a standardized, clinically meaningful GN metric to ensure consistent image quality evaluation and effective implementation of the CMS measure.
△ Less
Submitted 15 April, 2025;
originally announced April 2025.
-
The New CMS Measure of Excessive Radiation Dose or Inadequate CT Image Quality: Methods for Size-Adjusted Dose and Their Variabilities
Authors:
Gary Y Ge,
Charles M Weaver,
Jie Zhang
Abstract:
The Centers for Medicare & Medicaid Services (CMS) has introduced CMS1074v2, a quality measure for computed tomography (CT) that assesses radiation dose and image quality across 18 CT exam categories. This measure mandates the calculation of size-adjusted dose (SAD) using patient effective diameter and predefined size-adjustment coefficients. However, variability in SAD calculation methods raises…
▽ More
The Centers for Medicare & Medicaid Services (CMS) has introduced CMS1074v2, a quality measure for computed tomography (CT) that assesses radiation dose and image quality across 18 CT exam categories. This measure mandates the calculation of size-adjusted dose (SAD) using patient effective diameter and predefined size-adjustment coefficients. However, variability in SAD calculation methods raises concerns about standardization, compliance, and clinical applicability. This study evaluates five commonly used methods for estimating effective diameter and their impact on SAD determination in thoracic and abdominal CT protocols. A retrospective analysis of 719 CT exams was performed, comparing SAD values across different calculation approaches. Results indicate significant variability in SAD, with attenuation-based methods overestimating SAD in chest exams and projection-based methods exhibiting greater variability in abdominal exams. The findings highlight potential inconsistencies in CMS-defined dose thresholds and challenges in applying the measure across diverse patient populations and institutional imaging practices. Addressing these inconsistencies is critical for ensuring accurate dose reporting and maintaining diagnostic integrity in CT imaging.
△ Less
Submitted 9 March, 2025;
originally announced March 2025.
-
The nonlinear Dirac equation in Bose-Einstein condensates: I. Relativistic solitons in armchair nanoribbon optical lattices
Authors:
L. H. Haddad,
C. M. Weaver,
Lincoln D. Carr
Abstract:
We present a thorough analysis of soliton solutions to the quasi-one-dimensional nonlinear Dirac equation (NLDE) for a Bose-Einstein condensate in a honeycomb lattice with armchair geometry. Our NLDE corresponds to a quasi-one-dimensional reduction of the honeycomb lattice along the zigzag direction, in direct analogy to graphene nanoribbons. Excitations in the remaining large direction of the lat…
▽ More
We present a thorough analysis of soliton solutions to the quasi-one-dimensional nonlinear Dirac equation (NLDE) for a Bose-Einstein condensate in a honeycomb lattice with armchair geometry. Our NLDE corresponds to a quasi-one-dimensional reduction of the honeycomb lattice along the zigzag direction, in direct analogy to graphene nanoribbons. Excitations in the remaining large direction of the lattice correspond to the linear subbands in the armchair nanoribbon spectrum. Analytical as well as numerical soliton Dirac spinor solutions are obtained. We analyze the solution space of the quasi-one-dimensional NLDE by finding fixed points, delineating the various regions in solution space, and through an invariance relation which we obtain as a first integral of the NLDE. We obtain spatially oscillating multi-soliton solutions as well as asymptotically flat single soliton solutions using five different methods: by direct integration; an invariance relation; parametric transformation; a series expansion; and by numerical shooting. By tuning the ratio of the chemical potential to the nonlinearity for a fixed value of the energy-momentum tensor, we can obtain both bright and dark solitons over a nonzero density background.
△ Less
Submitted 15 February, 2015; v1 submitted 28 May, 2013;
originally announced May 2013.