-
Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Authors:
I. A. Sulai,
Z. J. DeLand,
M. D. Bulatowicz,
C. P. Wahl,
R. T. Wakai,
T. G. Walker
Abstract:
Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices (SQUIDs) due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free (SERF) vector atomic magnetic gradiometer with sens…
▽ More
Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices (SQUIDs) due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free (SERF) vector atomic magnetic gradiometer with sensitivity of $3\, \rm{fT} \,{cm}^{-1}{Hz}^{-1/2}$ and common mode rejection ratio (CMRR) $> 150$ in the band from DC to 100 Hz. We introduce a background suppression figure of merit for characterizing the performance of gradiometers. It allows for optimally setting the measurement baseline, and for quickly assessing the advantage, if any, of performing a measurement in gradiometric mode. As an application, we consider the problem of fetal magnetocardiography (fMCG) detection in the presence of a large background maternal MCG signal.
△ Less
Submitted 7 June, 2019;
originally announced June 2019.
-
A Compact, High Performance Atomic Magnetometer for Biomedical Applications
Authors:
Vishal K. Shah,
Ronald T. Wakai
Abstract:
We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2x2x5 cm^3 and it is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT/sqrt(Hz), which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) ma…
▽ More
We present a highly sensitive room-temperature atomic magnetometer (AM), designed for use in biomedical applications. The magnetometer sensor head is only 2x2x5 cm^3 and it is constructed using readily available, low-cost optical components. The magnetic field resolution of the AM is <10 fT/sqrt(Hz), which is comparable to cryogenically cooled superconducting quantum interference device (SQUID) magnetometers. We present side-by-side comparisons between our AM and a SQUID magnetometer, and show that equally high quality magnetoencephalography (MEG) and magnetocardiography (MCG) recordings can be obtained using our AM.
△ Less
Submitted 9 July, 2013;
originally announced July 2013.
-
Diffusive Suppression of AC-Stark Shifts in Atomic Magnetometers
Authors:
I. A. Sulai,
R. Wyllie,
M. Kauer,
G. S. Smetana,
R. T. Wakai,
T. G. Walker
Abstract:
In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small sub-volume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated w…
▽ More
In atomic magnetometers, the vector AC-Stark shift associated with circularly polarized light generates spatially varying effective magnetic fields which limit the magnetometer response and serve as sources of noise. We describe a scheme whereby optically pumping a small sub-volume of the magnetometer cell and relying on diffusion to transport polarized atoms allows a magnetometer to be operated with minimal sensitivity to the AC-Stark field.
△ Less
Submitted 21 December, 2012;
originally announced December 2012.
-
Optical Magnetometer Array for Fetal Magnetocardiography
Authors:
Robert Wyllie,
Matthew Kauer,
Ronald T. Wakai,
Thad G. Walker
Abstract:
We describe an array of spin-exchange relaxation free optical magnetometers designed for detection of fetal magnetocardiography (fMCG) signals. The individual magnetometers are configured with a small volume with intense optical pumping, surrounded by a large pump-free region. Spin-polarized atoms that diffuse out of the optical pumping region precess in the ambient magnetic field and are detected…
▽ More
We describe an array of spin-exchange relaxation free optical magnetometers designed for detection of fetal magnetocardiography (fMCG) signals. The individual magnetometers are configured with a small volume with intense optical pumping, surrounded by a large pump-free region. Spin-polarized atoms that diffuse out of the optical pumping region precess in the ambient magnetic field and are detected by a probe laser. Four such magnetometers, at the corners of a 7 cm square, are configured for gradiometry by feeding back the output of one magnetometer to a field coil to null uniform magnetic field noise at frequencies up to 200 Hz. Using this array, we present the first measurements of fMCG signals using an atomic magnetometer.
△ Less
Submitted 22 February, 2012;
originally announced February 2012.