The EPICS control system for IsoDAR
Authors:
Philip Weigel,
Monica Busza,
Abutalib Namazov,
Janette Park,
Joshua Villarreal,
Loyd H. Waites,
Daniel Winklehner
Abstract:
Many large accelerator facilities have adopted the open-source EPICS software as the quasi-industry standard for control systems. They typically have access to their own electronics laboratory and dedicated personnel for control system development. On the other hand, small laboratories, many based at universities, use commercial software like LabView, or entirely homebrewed systems. These often be…
▽ More
Many large accelerator facilities have adopted the open-source EPICS software as the quasi-industry standard for control systems. They typically have access to their own electronics laboratory and dedicated personnel for control system development. On the other hand, small laboratories, many based at universities, use commercial software like LabView, or entirely homebrewed systems. These often become cumbersome when the number of controlled devices increases over time. Here we present a control system setup, based on a combination of EPICS, React Automation Studio, and our own drivers for electronics available to smaller laboratories -- such as Arduinos -- that is flexible, modular, and robust. It allows small laboratories, working with off-the-shelf modular electronics, power supplies, and other devices to quickly set up a control system without a large facility overhead, while retaining maximum compatibility and upgradeability. We demonstrate our setup for the MIST-1 ion source experiment at MIT. This control system will later be used to serve the entire IsoDAR accelerator complex and, as such, must be easily expandable.
△ Less
Submitted 2 August, 2023; v1 submitted 28 June, 2023;
originally announced June 2023.
-
High Power Cyclotrons: The Bridge Between Beyond the Standard Model Physics, Computation, and Medical Applications
Authors:
Loyd Waites
Abstract:
The IsoDAR cyclotron is a 60 MeV cyclotron designed to output 10mA of protons in order to be a driver for a neutrino experiment. Coupling the high flux generated by the IsoDAR system with a kiloton neutrino detector will provide sterile neutrino exclusion searches covering anomalous regions indicated by short baseline experiments. Simultaneously, the coupling of a high power target and kiloton det…
▽ More
The IsoDAR cyclotron is a 60 MeV cyclotron designed to output 10mA of protons in order to be a driver for a neutrino experiment. Coupling the high flux generated by the IsoDAR system with a kiloton neutrino detector will provide sterile neutrino exclusion searches covering anomalous regions indicated by short baseline experiments. Simultaneously, the coupling of a high power target and kiloton detector allows for the investigation of dark matter candidates, namely axion-like particles. We have shown that nuclear excitations within the IsoDAR target create a unique opportunity to produce axions and detect monoenergetic peaks with the nearby kiloton detector. Beyond this, the high power produced by the IsoDAR cyclotron can be used for applications beyond particle physics. The IsoDAR cyclotron accelerates and extracts H$_2^+$, which allows the beam to be split downstream, a versatile and important development to alleviate the problem of producing high-power targets for the medical isotope community. This thesis presents a proposal for production of an more than an order of magnitude higher rates than are available at present for certain highly-need medical isotopes, including Ac-225.
In this thesis, we report results from a multi-cusp ion source that meets these requirements and produces a record level of high purity, low emittance H$_2^+$ current. The second has been to design a radio-frequency quadrupole (RFQ) that will allow for gentle bunching of the high current before injection. This is the first use of axial direct injection with a compact cyclotron. This thesis reports the first application of machine learning to the RFQ design. These tools enable the high currents required by IsoDAR cyclotron, leading to important impact on the accelerator, medical, and physics communities.
△ Less
Submitted 21 December, 2022;
originally announced December 2022.
-
Axion-Like Particle Production at Beam Dump Experiments with Distinct Nuclear Excitation Lines
Authors:
Loyd Waites,
Adrian Thompson,
Adriana Bungau,
Janet M. Conrad,
Bhaskar Dutta,
Wei-Chih Huang,
Doojin Kim,
Michael Shaevitz,
Joshua Spitz
Abstract:
Searches for axion-like particles (ALPs) are motivated by the strong CP problem in particle physics and by unexplained dark matter in astrophysics. In this letter, we discuss novel ALP searches using monoenergetic nuclear de-excitation photons from a beam dump, using IsoDAR as an example. We show that IsoDAR can set limits that close a gap in traditional QCD axion searches using the ALP-photon cou…
▽ More
Searches for axion-like particles (ALPs) are motivated by the strong CP problem in particle physics and by unexplained dark matter in astrophysics. In this letter, we discuss novel ALP searches using monoenergetic nuclear de-excitation photons from a beam dump, using IsoDAR as an example. We show that IsoDAR can set limits that close a gap in traditional QCD axion searches using the ALP-photon coupling, as well as provide sensitivity to large regions of new parameter space in models where ALPs couple to nucleons and electrons. We also show how isotope decay-at-rest experiments may be designed to improve potential ALP production and optimize detection sensitivity.
△ Less
Submitted 25 May, 2023; v1 submitted 27 July, 2022;
originally announced July 2022.
-
IsoDAR@Yemilab: A Report on the Technology, Capabilities, and Deployment
Authors:
Jose R. Alonso,
Daniel Winklehner,
Joshua Spitz,
Janet M. Conrad,
Seon-Hee Seo,
Yeongduk Kim,
Michael Shaevitz,
Adriana Bungau,
Roger Barlow,
Luciano Calabretta,
Andreas Adelmann,
Daniel Mishins,
Larry Bartoszek,
Loyd H. Waites,
Ki-Mun Bang,
Kang-Soon Park,
Erik A. Voirin
Abstract:
IsoDAR@Yemilab is a novel isotope-decay-at-rest experiment that has preliminary approval to run at the Yemi underground laboratory (Yemilab) in Jeongseon-gun, South Korea. In this technical report, we describe in detail the considerations for installing this compact particle accelerator and neutrino target system at the Yemilab underground facility. Specifically, we describe the caverns being prep…
▽ More
IsoDAR@Yemilab is a novel isotope-decay-at-rest experiment that has preliminary approval to run at the Yemi underground laboratory (Yemilab) in Jeongseon-gun, South Korea. In this technical report, we describe in detail the considerations for installing this compact particle accelerator and neutrino target system at the Yemilab underground facility. Specifically, we describe the caverns being prepared for IsoDAR, and address installation, hielding, and utilities requirements. To give context and for completeness, we also briefly describe the physics opportunities of the IsoDAR neutrino source when paired with the Liquid Scintillator Counter (LSC) at Yemilab, and review the technical design of the neutrino source.
△ Less
Submitted 11 July, 2022; v1 submitted 24 January, 2022;
originally announced January 2022.
-
Input Beam Matching and Beam Dynamics Design Optimization of the IsoDAR RFQ using Statistical and Machine Learning Techniques
Authors:
Daniel Koser,
Loyd Waites,
Daniel Winklehner,
Matthias Frey,
Andreas Adelmann,
Janet Conrad
Abstract:
We present a novel machine learning-based approach to generate fast-executing virtual radiofrequency quadrupole (RFQ) particle accelerators using surrogate modelling. These could potentially be used as on-line feedback tools during beam commissioning and operation, and to optimize the RFQ beam dynamics design prior to construction. Since surrogate models execute orders of magnitude faster than cor…
▽ More
We present a novel machine learning-based approach to generate fast-executing virtual radiofrequency quadrupole (RFQ) particle accelerators using surrogate modelling. These could potentially be used as on-line feedback tools during beam commissioning and operation, and to optimize the RFQ beam dynamics design prior to construction. Since surrogate models execute orders of magnitude faster than corresponding physics beam dynamics simulations using standard tools like PARMTEQM and RFQGen, the computational complexity of the multi-objective optimization problem reduces significantly. Ultimately, this presents a computationally inexpensive and time efficient method to perform sensitivity studies and an optimization of the crucial RFQ beam output parameters like transmission and emittances. Two different methods of surrogate model creation (polynomial chaos expansion and neural networks) are discussed and the achieved model accuracy is evaluated for different study cases with gradually increasing complexity, ranging from a simple FODO cell example to the full RFQ optimization. We find that variations of the beam input Twiss parameters can be reproduced well. The prediction of the beam with respect to hardware changes, e.g. of the electrode modulation, are challenging on the other hand. We discuss possible reasons.
△ Less
Submitted 5 December, 2021;
originally announced December 2021.
-
Neutrino Physics Opportunities with the IsoDAR Source at Yemilab
Authors:
J. Alonso,
C. A. Argüelles,
A. Bungau,
J. M. Conrad,
B. Dutta,
Y. D. Kim,
E. Marzec,
D. Mishins,
S. H. Seo,
M. Shaevitz,
J. Spitz,
A. Thompson,
L. Waites,
D. Winklehner
Abstract:
IsoDAR seeks to place a high-power-cyclotron and target combination, as an intense source of $\barν_e$ at the level of $\sim 10^{23}$/year, close to a kiloton-scale neutrino detector in order to gain sensitivity to very short-baseline neutrino oscillations ($\barν_e \rightarrow \barν_{e}$) and perform precision tests of the weak interaction, among other physics opportunities. Recently, IsoDAR has…
▽ More
IsoDAR seeks to place a high-power-cyclotron and target combination, as an intense source of $\barν_e$ at the level of $\sim 10^{23}$/year, close to a kiloton-scale neutrino detector in order to gain sensitivity to very short-baseline neutrino oscillations ($\barν_e \rightarrow \barν_{e}$) and perform precision tests of the weak interaction, among other physics opportunities. Recently, IsoDAR has received preliminary approval to be paired with the 2.26~kton target volume liquid scintillator detector at the Yemi Underground Laboratory (Yemilab) in Korea, at a 17~m center-to-center baseline, and cavern excavation for IsoDAR is now complete. In this paper, we present the physics capabilities of IsoDAR@Yemilab in terms of sensitivity to oscillations (via inverse beta decay, IBD; $\barν_e+p \rightarrow e^+ + n$), including initial-state wavepacket effects, and the weak mixing angle (via elastic scattering off atomic electrons, $\barν_e + e^- \rightarrow \barν_e + e^-$). We also introduce a study of IsoDAR sensitivity to new particles, such as a light $X$ boson, produced in the target that decays to $ν_e \bar ν_e$.
△ Less
Submitted 10 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
IsoDAR@Yemilab: A Conceptual Design Report for the Deployment of the Isotope Decay-At-Rest Experiment in Korea's New Underground Laboratory, Yemilab
Authors:
J. R. Alonso,
K. M. Bang,
R. Barlow,
L. Bartoszek,
A. Bungau,
L. Calabretta,
J. M. Conrad,
S. Kayser,
Y. D. Kim,
K. S. Park,
S. H. Seo,
M. H. Shaevitz,
J. Spitz,
L. H. Waites,
D. Winklehner
Abstract:
This Conceptual Design Report addresses the site-specific issues associated with the deployment of the IsoDAR experiment at the Yemilab site. IsoDAR@Yemilab pairs the IsoDAR cyclotron-driven $\barν_e$ source with the proposed Liquid Scintillator Counter (LSC) 2.5 kton detector. This document describes the proposed siting: requirements for the caverns to house the cyclotron, beam transport line, an…
▽ More
This Conceptual Design Report addresses the site-specific issues associated with the deployment of the IsoDAR experiment at the Yemilab site. IsoDAR@Yemilab pairs the IsoDAR cyclotron-driven $\barν_e$ source with the proposed Liquid Scintillator Counter (LSC) 2.5 kton detector. This document describes the proposed siting: requirements for the caverns to house the cyclotron, beam transport line, and target systems; issues associated with transport and assembly of components on the site; electrical power, cooling and ventilation; as well as issues associated with radiation protection of the environment and staff of Yemilab who will be interfacing with IsoDAR during its operational phases. The onset of construction of the IsoDAR area at Yemilab, in tandem with the release of this design report, represents a key step forward in establishing IsoDAR@Yemilab.
△ Less
Submitted 28 December, 2021; v1 submitted 20 October, 2021;
originally announced October 2021.
-
High current $\mathrm{H}_2^+$ beams from a filament-driven multicusp ion source
Authors:
Daniel Winklehner,
Janet M. Conrad,
Joseph Smolsky,
Loyd Waites
Abstract:
Recently, the use of $\mathrm{H}_2^+$ ions instead of protons to overcome space charge challenges in compact cyclotrons has received much attention. This technique has the potential to increase the available beam current from compact cyclotrons by an order of magnitude, paving the way for applications in energy research, medical isotope production, and particle physics, e.g. a decisive search for…
▽ More
Recently, the use of $\mathrm{H}_2^+$ ions instead of protons to overcome space charge challenges in compact cyclotrons has received much attention. This technique has the potential to increase the available beam current from compact cyclotrons by an order of magnitude, paving the way for applications in energy research, medical isotope production, and particle physics, e.g. a decisive search for sterile neutrinos through the IsoDAR experiment. For IsoDAR we go a step beyond just using $\mathrm{H}_2^+$ and add pre-bunching through a Radio-Frequency Quadrupole (RFQ) embedded in the cyclotron yoke. This puts beam purity and beam quality constraints on the ion source that no published ion source has simultaneously demonstrated so far. Here, we report results from a new multicusp ion source (MIST-1) that produces the world's highest steady-state current of $\mathrm{H}_2^+$ from this type of ion source (1 mA), with exceptionally low emittance (0.05 $π$-mm-mrad, RMS, normalized) and high purity (80% $\mathrm{H}_2^+$). This result shows the feasibility of using a multicusp ion source for IsoDAR and the RFQ direct injection prototype, and paves the way to record breaking continuous wave (cw) beam currents of 5 mA $\mathrm{H}_2^+$ (equivalent to 10 mA protons) from compact cyclotrons, ideal for underground installation. This represents a significant advance, with impact on neutrino physics specifically and high power cyclotron design in general.
△ Less
Submitted 10 March, 2021; v1 submitted 27 August, 2020;
originally announced August 2020.
-
Medical Isotope Production with the IsoDAR Cyclotron
Authors:
Jose R. Alonso,
Roger Barlow,
Janet M. Conrad,
Loyd Hoyt Waites
Abstract:
Authors describe technical advances that will allow the IsoDAR cyclotron -- being developed for neutrino physics research -- to produce medical isotopes more efficiently than existing cyclotrons can.
Authors describe technical advances that will allow the IsoDAR cyclotron -- being developed for neutrino physics research -- to produce medical isotopes more efficiently than existing cyclotrons can.
△ Less
Submitted 19 March, 2020; v1 submitted 17 March, 2020;
originally announced March 2020.
-
First Commissioning Results of the Multicusp Ion Source at MIT (MIST-1) for H$_2^+$
Authors:
Daniel Winklehner,
Spencer Axani,
Patrick Bedard,
Janet Conrad,
Jesus Corona,
Frances Hartwell,
Joseph Smolsky,
Aashish Tripathee,
Loyd Waites,
Philip Weigel,
Thomas Wester,
Maria Yampolskaya
Abstract:
IsoDAR is an experiment under development to search for sterile neutrinos using the isotope Decay-At-Rest (DAR) production mechanism, where protons impinging on $^9$Be create neutrons which capture on $^7$Li which then beta-decays producing $\barν_e$. As this will be an isotropic source of $\barν_e$, the primary driver current must be large (10 mA cw) for IsoDAR to have sufficient statistics to be…
▽ More
IsoDAR is an experiment under development to search for sterile neutrinos using the isotope Decay-At-Rest (DAR) production mechanism, where protons impinging on $^9$Be create neutrons which capture on $^7$Li which then beta-decays producing $\barν_e$. As this will be an isotropic source of $\barν_e$, the primary driver current must be large (10 mA cw) for IsoDAR to have sufficient statistics to be conclusive within 5 years of running. H$_2^+$ was chosen as primary ion to overcome some of the space-charge limitations during low energy beam transport and injection into a compact cyclotron. The H$_2^+$ will be stripped into protons before the target. At MIT, a multicusp ion source (MIST-1) was designed and built to produce a high intensity beam with a high H$_2^+$ fraction. MIST-1 is now operational at the Plasma Science and Fusion Center (PSFC) at MIT and under commissioning.
△ Less
Submitted 5 November, 2018;
originally announced November 2018.
-
What is the Potential Impact of the IsoDAR Cyclotron on Radioisotope Production: A Review
Authors:
Loyd Hoyt Waites,
Jose R Alonso,
Roger Barlow,
Janet Conrad
Abstract:
The IsoDAR collaboration is developing a high-current cyclotron for a neutrino search experiment. Designed to deliver 10 mA of 60 MeV protons, the current and power of this cyclotron far exceed those of existing accelerators, opening new possibilities for the production of radiopharmaceutical isotopes, producing very high-activity samples in very short times. The cyclotron can also be easily confi…
▽ More
The IsoDAR collaboration is developing a high-current cyclotron for a neutrino search experiment. Designed to deliver 10 mA of 60 MeV protons, the current and power of this cyclotron far exceed those of existing accelerators, opening new possibilities for the production of radiopharmaceutical isotopes, producing very high-activity samples in very short times. The cyclotron can also be easily configured to deliver ions other than protons including 1 mA of alpha particles at 240 MeV: this flexibility gives a broad reach into new areas of isotope production. We explain how IsoDAR overcomes the beam limits of commercial cyclotrons, and how it could represent the next step in isotope production rates.
△ Less
Submitted 19 March, 2020; v1 submitted 17 July, 2018;
originally announced July 2018.
-
High intensity cyclotrons for neutrino physics
Authors:
Daniel Winklehner,
Jungbae Bahng,
Luciano Calabretta,
Alessandra Calanna,
Alok Chakrabarti,
Janet Conrad,
Grazia D'Agostino,
Siddharta Dechoudhury,
Vaishali Naik,
Loyd Waites,
Philip Weigel
Abstract:
In recent years, the interest in high intensity proton beams in excess of several milli-Amperes has risen. Potential applications are in neutrino physics, materials and energy research, and isotope production. Continuous wave proton beams of five to ten milli-Amperes are now in reach due to advances in accelerator technology and through improved understanding of the beam dynamics. As an example ap…
▽ More
In recent years, the interest in high intensity proton beams in excess of several milli-Amperes has risen. Potential applications are in neutrino physics, materials and energy research, and isotope production. Continuous wave proton beams of five to ten milli-Amperes are now in reach due to advances in accelerator technology and through improved understanding of the beam dynamics. As an example application, we present the proposed IsoDAR experiment, a search for so-called sterile neutrinos and non-standard interaction using the KamLAND detector located in Japan. We present updated sensitivities for this experiment and describe in detail the design of the high intensity proton driver that uses several novel ideas. These are: accelerating H2+ instead of protons, directly injecting beam into the cyclotron via a Radio Frequency Quadrupole (RFQ), and carefully matching the beam to achieve so-called vortex motion. The preliminary design holds up well in PIC simulation studies and the injector system is now being constructed, to be commissioned with a 1 MeV test cyclotron.
△ Less
Submitted 5 November, 2018; v1 submitted 10 July, 2018;
originally announced July 2018.