-
Verification of the Timing System for the X-ray Imaging and Spectroscopy Mission in the GPS Unsynchronized Mode
Authors:
Megumi Shidatsu,
Yukikatsu Terada,
Takashi Kominato,
So Kato,
Ryohei Sato,
Minami Sakama,
Takumi Shioiri,
Yugo Motogami,
Yuuki Niida,
Chulsoo Kang,
Toshihiro Takagi,
Taichi Nakamoto,
Chikara Natsukari,
Makoto S. Tashiro,
Kenichi Toda,
Hironori Maejima,
Shin Watanabe,
Ryo Iizuka,
Rie Sato,
Chris Baluta,
Katsuhiro Hayashi,
Tessei Yoshida,
Shoji Ogawa,
Yoshiaki Kanemaru,
Kotaro Fukushima
, et al. (37 additional authors not shown)
Abstract:
We report the results from the ground and on-orbit verifications of the XRISM timing system when the satellite clock is not synchronized to the GPS time. In this case, the time is determined by a free-run quartz oscillator of the clock, whose frequency changes depending on its temperature. In the thermal vacuum test performed in 2022, we obtained the GPS unsynchronized mode data and the temperatur…
▽ More
We report the results from the ground and on-orbit verifications of the XRISM timing system when the satellite clock is not synchronized to the GPS time. In this case, the time is determined by a free-run quartz oscillator of the clock, whose frequency changes depending on its temperature. In the thermal vacuum test performed in 2022, we obtained the GPS unsynchronized mode data and the temperature-versus-clock frequency trend. Comparing the time values calculated from the data and the true GPS times when the data were obtained, we confirmed that the requirement (within a 350 $μ$s error in the absolute time, accounting for both the spacecraft bus system and the ground system) was satisfied in the temperature conditions of the thermal vacuum test. We also simulated the variation of the timing accuracy in the on-orbit temperature conditions using the Hitomi on-orbit temperature data and found that the error remained within the requirement over $\sim 3 \times 10^{5}$ s. The on-orbit tests were conducted in 2023 September and October as part of the bus system checkout. The temperature versus clock frequency trend remained unchanged from that obtained in the thermal vacuum test and the observed time drift was consistent with that expected from the trend.
△ Less
Submitted 3 June, 2025;
originally announced June 2025.
-
Development of the Timing System for the X-Ray Imaging and Spectroscopy Mission
Authors:
Yukikatsu Terada,
Megumi Shidatsu,
Makoto Sawada,
Takashi Kominato,
So Kato,
Ryohei Sato,
Minami Sakama,
Takumi Shioiri,
Yuki Niida,
Chikara Natsukari,
Makoto S Tashiro,
Kenichi Toda,
Hironori Maejima,
Katsuhiro Hayashi,
Tessei Yoshida,
Shoji Ogawa,
Yoshiaki Kanemaru,
Akio Hoshino,
Kotaro Fukushima,
Hiromitsu Takahashi,
Masayoshi Nobukawa,
Tsunefumi Mizuno,
Kazuhiro Nakazawa,
Shin'ichiro Uno,
Ken Ebisawa
, et al. (40 additional authors not shown)
Abstract:
This paper describes the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0~ms. All components of the timing system were designed and verified to be within the timing error budgets, whi…
▽ More
This paper describes the development, design, ground verification, and in-orbit verification, performance measurement, and calibration of the timing system for the X-Ray Imaging and Spectroscopy Mission (XRISM). The scientific goals of the mission require an absolute timing accuracy of 1.0~ms. All components of the timing system were designed and verified to be within the timing error budgets, which were assigned by component to meet the requirements. After the launch of XRISM, the timing capability of the ground-tuned timing system was verified using the millisecond pulsar PSR~B1937+21 during the commissioning period, and the timing jitter of the bus and the ground component were found to be below $15~μ$s compared to the NICER (Neutron star Interior Composition ExploreR) profile. During the performance verification and calibration period, simultaneous observations of the Crab pulsar by XRISM, NuSTAR (Nuclear Spectroscopic Telescope Array), and NICER were made to measure the absolute timing offset of the system, showing that the arrival time of the main pulse with XRISM was aligned with that of NICER and NuSTAR to within $200~μ$s. In conclusion, the absolute timing accuracy of the bus and the ground component of the XRISM timing system meets the timing error budget of $500~μ$s.
△ Less
Submitted 17 March, 2025;
originally announced March 2025.
-
Container-Based Pre-Pipeline Data Processing on HPC for XRISM
Authors:
Satoshi Eguchi,
Makoto Tashiro,
Yukikatsu Terada,
Hiromitsu Takahashi,
Masayoshi Nobukawa,
Ken Ebisawa,
Katsuhiro Hayashi,
Tessei Yoshida,
Yoshiaki Kanemaru,
Shoji Ogawa,
Matthew P. Holland,
Michael Loewenstein,
Eric D. Miller,
Tahir Yaqoob,
Robert S. Hill,
Morgan D. Waddy,
Mark M. Mekosh,
Joseph B. Fox,
Isabella S. Brewer,
Emily Aldoretta,
XRISM Science Operations Team
Abstract:
The X-Ray Imaging and Spectroscopy Mission (XRISM) is the 7th Japanese X-ray observatory, whose development and operation are in collaboration with universities and research institutes in Japan, U.S., and Europe, including JAXA, NASA, and ESA. The telemetry data downlinked from the satellite are reduced to scientific products by the pre-pipeline (PPL) and pipeline (PL) software running on standard…
▽ More
The X-Ray Imaging and Spectroscopy Mission (XRISM) is the 7th Japanese X-ray observatory, whose development and operation are in collaboration with universities and research institutes in Japan, U.S., and Europe, including JAXA, NASA, and ESA. The telemetry data downlinked from the satellite are reduced to scientific products by the pre-pipeline (PPL) and pipeline (PL) software running on standard Linux virtual machines on the JAXA and NASA sides, respectively. We ported the PPL to the JAXA "TOKI-RURI" high-performance computing (HPC) system capable of completing $\simeq 160$ PPL processes within 24 hours by utilizing the container platform of Singularity and its "--bind" option. In this paper, we briefly show the data processing in XRISM and present our porting strategy of PPL to the HPC environment in detail.
△ Less
Submitted 17 December, 2024;
originally announced December 2024.