Effects of Distributed Generation on the Bidirectional Operation of Cascaded Step Voltage Regulators: Case Study of a Real 34.5 kV Distribution Feeder
Authors:
Hugo Rodrigues de Brito,
Valéria Monteiro de Souza,
João Paulo Abreu Vieira,
Maria Emília de Lima Tostes,
Ubiratan Holanda Bezerra,
Vanderson Carvalho de Souza,
Daniel da Conceição Pinheiro,
Heitor Alves Barata,
Hugo Nazareno de Souza Cardoso,
Marcelo Sousa Costa
Abstract:
This work investigates the impact of feeder bidirectional active power flow on the operation of two cascaded step voltage regulators (SVRs) located at a 34.5 kV rural distribution feeder. It shows that, when active power flow reversal is possible both by network reconfiguration and by high penetration levels of distributed generation (DG), typical SVR control mode settings are unable to prevent th…
▽ More
This work investigates the impact of feeder bidirectional active power flow on the operation of two cascaded step voltage regulators (SVRs) located at a 34.5 kV rural distribution feeder. It shows that, when active power flow reversal is possible both by network reconfiguration and by high penetration levels of distributed generation (DG), typical SVR control mode settings are unable to prevent the occurrence of runaway condition, a phenomenon characterized by loss of SVR voltage control capabilities. Such developments are the basis for a DG pre-dispatch control strategy that aims to avoid the adverse effects of the described power flow reversal scenarios, as well as to ensure reliable operation of the utility distribution network.
△ Less
Submitted 13 October, 2023;
originally announced October 2023.
Comparison between Conventional Load Flow, QSTS Simulation, and Dynamic Simulation to Assess the Operation of Step Voltage Regulators in Active Distribution Networks
Authors:
V. M. Souza,
H. R. Brito,
J. P. A. Vieira,
M. E. L. Tostes,
U. H. Bezerra,
H. N. S. Cardoso,
M. S. Costa
Abstract:
The assessment of step voltage regulator (SVR) operation in active distribution networks requires computational analysis tools capable of tackling the emerging technical challenges. Conventional load flow (CLF), quasi-static time series (QSTS) and dynamic simulations are typically employed to investigate high-penetration distributed generation (DG) interconnection impacts. Regarding the SVR runawa…
▽ More
The assessment of step voltage regulator (SVR) operation in active distribution networks requires computational analysis tools capable of tackling the emerging technical challenges. Conventional load flow (CLF), quasi-static time series (QSTS) and dynamic simulations are typically employed to investigate high-penetration distributed generation (DG) interconnection impacts. Regarding the SVR runaway condition phenomenon, however, a consensus has yet to be reached on the most cost-effective simulation technique for capturing and reproducing the correct sequence of events. This work presents a comparative study of the CLF, QSTS and dynamic simulation techniques through modelling and analysis of two SVR-controlled test-feeders, in order to evaluate each approach performance in addressing scenarios of DG-caused reverse active power flow. Detailed descriptions of feeder voltage profile and SVR tap operations are provided to facilitate understanding of the mechanisms that characterize SVR runaway condition, as well as the advantages and drawbacks of each of the studied simulation techniques.
△ Less
Submitted 13 October, 2023;
originally announced October 2023.