Comparison Between Damping Coefficients of Measured Perforated Micromechanical Test Structures and Compact Models
Abstract: Measured damping coefficients of six different perforated micromechanical test structures are compared with damping coefficients given by published compact models. The motion of the perforated plates is almost translational, the surface shape is rectangular, and the perforation is uniform validating the assumptions made for compact models. In the structures, the perforation ratio varies from 24%… ▽ More
Submitted 7 May, 2008; originally announced May 2008.
Comments: Submitted on behalf of EDA Publishing Association (http://irevues.inist.fr/handle/2042/16838)
Journal ref: Dans Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS - DTIP 2008, Nice : France (2008)