Non-unique water and contrast agent solutions in dual-energy CT
Authors:
JP Phillips,
Emil Y. Sidky,
Fatma Terzioglu,
Ingrid S. Reiser,
Guillaume Bal,
Xiaochuan Pan
Abstract:
The goal of this work is to study occurrences of non-unique solutions in dual-energy CT (DECT) for objects containing water and a contrast agent. Previous studies of the Jacobian of nonlinear systems identified that a vanishing Jacobian determinant indicates the existence of multiple solutions to the system. Vanishing Jacobian determinants are identified for DECT setups by simulating intensity dat…
▽ More
The goal of this work is to study occurrences of non-unique solutions in dual-energy CT (DECT) for objects containing water and a contrast agent. Previous studies of the Jacobian of nonlinear systems identified that a vanishing Jacobian determinant indicates the existence of multiple solutions to the system. Vanishing Jacobian determinants are identified for DECT setups by simulating intensity data for practical thickness ranges of water and contrast agent. Once existence is identified, non-unique solutions are found by simulating scan data and finding intensity contours with that intersect multiple times. With this process non-unique solutions are found for DECT setups scanning iodine and gadolinium, including setups using tube potentials in practical ranges. Non-unique solutions demonstrate a large range of differences and can result in significant discrepancies between recovered and true material mapping.
△ Less
Submitted 19 November, 2024;
originally announced November 2024.
-
Optimizing dual-energy CT technique for iodine-based contrast-to-noise ratio
Authors:
Fatma Terzioglu,
Emil Y. Sidky,
Jp Phillips,
Ingrid Reiser,
Guillaume Bal,
Xiaochuan Pan
Abstract:
Purpose: This study proposes a systematic method for determining the optimal x-ray tube settings/energy windows and fluence for minimal noise and maximum CNR in material density images obtained from DECT scans by fixing the subject size and the total radiation dose. Methods: The noise propagation in the process of sinogram and image reconstruction from DECT measurements is analyzed. Analytic estim…
▽ More
Purpose: This study proposes a systematic method for determining the optimal x-ray tube settings/energy windows and fluence for minimal noise and maximum CNR in material density images obtained from DECT scans by fixing the subject size and the total radiation dose. Methods: The noise propagation in the process of sinogram and image reconstruction from DECT measurements is analyzed. Analytic estimates for the sinogram and monochromatic image pixel variances and the CNR as functions of tube potentials, fluence, and virtual monochromatic image (VMI) energy are derived, and then used in a phantom experiment as an objective function for optimizing the tube settings to minimize the image noise and maximize the CNR. Results: A non-trivial example that shows the existence of singular solutions to the inversion of sinograms-to-DECT measurements map was presented. Additionally, the optimal VMI energy for maximal CNR was determined. The optimal energy VMI was found to be the least noisy monochromatic image synthesized from the iodine and water density images, and it was shown that using more general weights in combining the two images linearly does not improve image quality. When the x-ray beam filter material was fixed at 2mm of Aluminum and the photon fluence for low and high kV scans were considered equal, the tube potential pair of 60/120 kV led to the maximal CNR in the VMI formed at energy 55 KeV. Conclusions: Optimizing DECT scan parameters to maximize the CNR can be done in a systematic way. Also choosing the parameters that maximize the Jacobian determinant over the sinogram domain would lead to more stable reconstructions due to the reduced amplification of the measurement noise. Since the values of the Jacobian determinant depend strongly on the imaging task, careful consideration of all of the relevant factors is needed when implementing the proposed framework.
△ Less
Submitted 28 July, 2023;
originally announced August 2023.
-
An inversion algorithm for P-functions with applications to Multi-energy CT
Authors:
Guillaume Bal,
Ruoming Gong,
Fatma Terzioglu
Abstract:
Multi-energy computed tomography (ME-CT) is an x-ray transmission imaging technique that uses the energy dependence of x-ray photon attenuation to determine the elemental composition of an object of interest. Mathematically, forward ME-CT measurements are modeled by a nonlinear integral transform. In this paper, local conditions for global invertibility of the ME-CT transform are studied, and expl…
▽ More
Multi-energy computed tomography (ME-CT) is an x-ray transmission imaging technique that uses the energy dependence of x-ray photon attenuation to determine the elemental composition of an object of interest. Mathematically, forward ME-CT measurements are modeled by a nonlinear integral transform. In this paper, local conditions for global invertibility of the ME-CT transform are studied, and explicit stability estimates quantifying the error propagation from measurements to reconstructions are provided. Motivated from the inverse problem of image reconstruction in ME-CT, an iterative inversion algorithm for the so-called P-functions is proposed. Numerical simulations for ME-CT, in two and three materials settings with an equal number of energy measurements, confirm the theoretical predictions.
△ Less
Submitted 29 September, 2021;
originally announced October 2021.
-
Uniqueness criteria in multi-energy CT
Authors:
Guillaume Bal,
Fatma Terzioglu
Abstract:
Multi-Energy Computed Tomography (ME-CT) is a medical imaging modality aiming to reconstruct the spatial density of materials from the attenuation properties of probing x-rays. For each line in two- or three-dimensional space, ME-CT measurements may be written as a nonlinear mapping from the integrals of the unknown densities of a finite number of materials along said line to an equal or larger nu…
▽ More
Multi-Energy Computed Tomography (ME-CT) is a medical imaging modality aiming to reconstruct the spatial density of materials from the attenuation properties of probing x-rays. For each line in two- or three-dimensional space, ME-CT measurements may be written as a nonlinear mapping from the integrals of the unknown densities of a finite number of materials along said line to an equal or larger number of energy-weighted integrals corresponding to different x-ray source energy spectra. ME-CT reconstructions may thus be decomposed as a two-step process: (i) reconstruct line integrals of the material densities from the available energy measurements; and (ii) reconstruct densities from their line integrals. Step (ii) is the standard linear x-ray CT problem whose invertibility is well-known, so this paper focuses on step (i). We show that ME-CT admits stable, global inversion provided that (a well-chosen linear transform of) the differential of the transform in step (i) satisfies appropriate orientation constraints that makes it a P-matrix. We introduce a notion of quantitative P-function that allows us to derive global stability results for ME-CT in the determined as well as over-determined (with more source energy spectra than the number of materials) cases. Numerical simulations based on standard material properties in imaging applications (of bone, water, contrast agents) and well accepted models of source energy spectra show that ME-CT is often (always in our simulations) either (i) non-globally injective because it is non-injective locally (differential not of full rank), or (ii) globally injective as soon as it is locally injective (differentials satisfy our proposed constraints).
△ Less
Submitted 6 January, 2020;
originally announced January 2020.
-
Inversion of Weighted Divergent Beam and Cone Transforms
Authors:
Peter Kuchment,
Fatma Terzioglu
Abstract:
In this paper, we investigate the relations between the Radon and weighted divergent beam and cone transforms. Novel inversion formulas are derived for the latter two. The weighted cone transform arises, for instance, in image reconstruction from the data obtained by Compton cameras, which have promising applications in various fields, including biomedical and homeland security imaging and gamma r…
▽ More
In this paper, we investigate the relations between the Radon and weighted divergent beam and cone transforms. Novel inversion formulas are derived for the latter two. The weighted cone transform arises, for instance, in image reconstruction from the data obtained by Compton cameras, which have promising applications in various fields, including biomedical and homeland security imaging and gamma ray astronomy. The inversion formulas are applicable for a wide variety of detector geometries in any dimension. The results of numerical implementation of some of the formulas in dimensions two and three are also provided.
△ Less
Submitted 22 December, 2016; v1 submitted 20 December, 2016;
originally announced December 2016.
-
3D Image Reconstruction from Compton camera data
Authors:
Peter Kuchment,
Fatma Terzioglu
Abstract:
In this paper, we address analytically and numerically the inversion of the integral transform (\emph{cone} or \emph{Compton} transform) that maps a function on $\mathbb{R}^3$ to its integrals over conical surfaces. It arises in a variety of imaging techniques, e.g. in astronomy, optical imaging, and homeland security imaging, especially when the so called Compton cameras are involved.
Several i…
▽ More
In this paper, we address analytically and numerically the inversion of the integral transform (\emph{cone} or \emph{Compton} transform) that maps a function on $\mathbb{R}^3$ to its integrals over conical surfaces. It arises in a variety of imaging techniques, e.g. in astronomy, optical imaging, and homeland security imaging, especially when the so called Compton cameras are involved.
Several inversion formulas are developed and implemented numerically in $3D$ (the much simpler $2D$ case was considered in a previous publication). An admissibility condition on detectors geometry is formulated, under which all these inversion techniques will work.
△ Less
Submitted 17 August, 2016; v1 submitted 11 April, 2016;
originally announced April 2016.
-
Some Inversion Formulas for the Cone Transform
Authors:
Fatma Terzioglu
Abstract:
Several novel imaging applications have lead recently to a variety of Radon type transforms, where integration is done over a family of conical surfaces. We call them \emph{cone transforms} (in 2D they are also called \emph{V-line} or \emph{broken ray} transforms). Most prominently, they are present in the so called Compton camera imaging that arises in medical diagnostics, astronomy, and lately i…
▽ More
Several novel imaging applications have lead recently to a variety of Radon type transforms, where integration is done over a family of conical surfaces. We call them \emph{cone transforms} (in 2D they are also called \emph{V-line} or \emph{broken ray} transforms). Most prominently, they are present in the so called Compton camera imaging that arises in medical diagnostics, astronomy, and lately in homeland security applications. Several specific incarnations of the cone transform have been considered separately. In this paper, we address the most general (and overdetermined) cone transform, obtain integral relations between cone and Radon transforms in $\mathbb{R}^n$, and a variety of inversion formulas. In many applications (e.g., in homeland security), the signal to noise ratio is very low. So, if overdetermined data is collected (as in the case of Compton imaging), attempts to reduce the dimensionality might lead to essential elimination of the signal. Thus, our main concentration is on obtaining formulas involving overdetermined data.
△ Less
Submitted 23 September, 2015; v1 submitted 1 April, 2015;
originally announced April 2015.