-
An angular-selective electron source for the KATRIN experiment
Authors:
M. Beck,
K. Bokeloh,
H. Hein,
S. Bauer,
H. Baumeister,
J. Bonn,
H. -W. Ortjohann,
B. Ostrick,
S. Rosendahl,
S. Streubel,
K. Valerius,
M. Zboril,
C. Weinheimer
Abstract:
The KATRIN experiment is going to search for the average mass of the electron antineutrino with a sensitivity of 0.2 eV/c2. It uses a retardation spectrometer of MAC-E filter type to accurately measure the shape of the electron spectrum at the endpoint of tritium beta decay. In order to achieve the planned sensitivity the transmission properties of the spectrometer have to be understood with high…
▽ More
The KATRIN experiment is going to search for the average mass of the electron antineutrino with a sensitivity of 0.2 eV/c2. It uses a retardation spectrometer of MAC-E filter type to accurately measure the shape of the electron spectrum at the endpoint of tritium beta decay. In order to achieve the planned sensitivity the transmission properties of the spectrometer have to be understood with high precision for all initial conditions. For this purpose an electron source has been developed that emits single electrons at adjustable total energy and adjustable emission angle. The emission is pointlike and can be moved across the full flux tube that is imaged onto the detector. Here, we demonstrate that this novel type of electron source can be used to investigate the transmission properties of a MAC-E filter in detail.
△ Less
Submitted 1 November, 2014;
originally announced November 2014.
-
Classical calculation of relativistic frequency-shifts in an ideal Penning trap
Authors:
Jochen Ketter,
Tommi Eronen,
Martin Höcker,
Marc Schuh,
Sebastian Streubel,
Klaus Blaum
Abstract:
The ideal Penning trap consists of a uniform magnetic field and an electrostatic quadrupole potential. In the classical low-energy limit, the three characteristic eigenfrequencies of a charged particle trapped in this configuration do not depend on the amplitudes of the three eigenmotions. No matter how accurate the experimental realization of the ideal Penning trap, its harmonicity is ultimately…
▽ More
The ideal Penning trap consists of a uniform magnetic field and an electrostatic quadrupole potential. In the classical low-energy limit, the three characteristic eigenfrequencies of a charged particle trapped in this configuration do not depend on the amplitudes of the three eigenmotions. No matter how accurate the experimental realization of the ideal Penning trap, its harmonicity is ultimately compromised by special relativity. Using a classical formalism of first-order perturbation theory, we calculate the relativistic frequency-shifts associated with the motional degrees of freedom for a spinless particle stored in an ideal Penning trap, and we compare the results with the simple but surprisingly accurate model of relativistic mass-increase.
△ Less
Submitted 6 March, 2014; v1 submitted 16 October, 2013;
originally announced October 2013.
-
First-order perturbative calculation of the frequency-shifts caused by static cylindrically-symmetric electric and magnetic imperfections of a Penning trap
Authors:
Jochen Ketter,
Tommi Eronen,
Martin Höcker,
Sebastian Streubel,
Klaus Blaum
Abstract:
The ideal Penning trap consists of a uniform magnetic field and an electrostatic quadrupole potential. Cylindrically-symmetric deviations thereof are parametrized by the coefficients Bn and Cn, respectively. Relativistic mass-increase aside, the three characteristic eigenfrequencies of a charged particle stored in an ideal Penning trap are independent of the three motional amplitudes. This three-f…
▽ More
The ideal Penning trap consists of a uniform magnetic field and an electrostatic quadrupole potential. Cylindrically-symmetric deviations thereof are parametrized by the coefficients Bn and Cn, respectively. Relativistic mass-increase aside, the three characteristic eigenfrequencies of a charged particle stored in an ideal Penning trap are independent of the three motional amplitudes. This three-fold harmonicity is a highly-coveted virtue for precision experiments that rely on the measurement of at least one eigenfrequency in order to determine fundamental properties of the stored particle, such as its mass. However, higher-order contributions to the ideal fields result in amplitude-dependent frequency-shifts. In turn, these frequency-shifts need to be understood for estimating systematic experimental errors, and eventually for correcting them by means of calibrating the imperfections. The problem of calculating the frequency-shifts caused by small imperfections of a near-ideal trap yields nicely to perturbation theory, producing analytic formulas that are easy to evaluate for the relevant parameters of an experiment. In particular, the frequency-shifts can be understood on physical rather than purely mathematical grounds by considering which terms actually drive them. Based on identifying these terms, we derive general formulas for the first-order frequency-shifts caused by any perturbation parameter Bn or Cn.
△ Less
Submitted 9 January, 2014; v1 submitted 21 May, 2013;
originally announced May 2013.
-
A UV LED-based fast-pulsed photoelectron source for time-of-flight studies
Authors:
K. Valerius,
M. Beck,
H. Arlinghaus,
J. Bonn,
V. M. Hannen,
H. Hein,
B. Ostrick,
S. Streubel,
Ch. Weinheimer,
M. Zboril
Abstract:
We report on spectroscopy and time-of-flight measurements using an 18 keV fast-pulsed photoelectron source of adjustable intensity, ranging from single photoelectrons per pulse to 5 photoelectrons per microsecond at pulse repetition rates of up to 10 kHz. Short pulses between 40 ns and 40 microseconds in length were produced by switching light emitting diodes with central output wavelengths of 2…
▽ More
We report on spectroscopy and time-of-flight measurements using an 18 keV fast-pulsed photoelectron source of adjustable intensity, ranging from single photoelectrons per pulse to 5 photoelectrons per microsecond at pulse repetition rates of up to 10 kHz. Short pulses between 40 ns and 40 microseconds in length were produced by switching light emitting diodes with central output wavelengths of 265 nm and 257 nm, in the deep ultraviolet (or UV-C) regime, at kHz frequencies. Such photoelectron sources can be useful calibration devices for testing the properties of high-resolution electrostatic spectrometers, like the ones used in current neutrino mass searches.
△ Less
Submitted 17 June, 2009; v1 submitted 13 February, 2009;
originally announced February 2009.
-
Nonlinear ac susceptibility studies of high-$T_c$ rings: Influence of the structuring method and determination of the flux creep exponent
Authors:
S. Streubel,
F. Mrowka,
M. Wurlitzer,
P. Esquinazi,
K. Zimmer
Abstract:
We have studied the influence of the patterning procedure on the critical current density of high-$T_c$ YBa$_2$Cu$_3$O$_{7-δ}$ thin rings using the nonlinear ac susceptibility method. At no applied dc magnetic field we have found that laser ablation degrades strongly the critical current density whereas ion beam etching has only a weak influence on it. From the measurements at different frequenc…
▽ More
We have studied the influence of the patterning procedure on the critical current density of high-$T_c$ YBa$_2$Cu$_3$O$_{7-δ}$ thin rings using the nonlinear ac susceptibility method. At no applied dc magnetic field we have found that laser ablation degrades strongly the critical current density whereas ion beam etching has only a weak influence on it. From the measurements at different frequencies and dc magnetic fields we analyzed the influence of flux creep and obtained the field dependence of the flux creep exponent. Our data reconfirm the recently observed scaling relation for the nonlinear susceptibility response of type-II superconductors.
△ Less
Submitted 28 March, 2000;
originally announced March 2000.