-
Project 8 Apparatus for Cyclotron Radiation Emission Spectroscopy with $^\mathrm{83m}$Kr and Tritium
Authors:
A. Ashtari Esfahani,
D. M. Asner,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
P. J. Doe,
J. L. Fernandes,
M. Fertl,
J. A. Formaggio,
D. Furse,
L. Gladstone,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
J. A. Kofron,
B. H. LaRoque,
A. Lindman,
E. Machado,
E. L. McBride,
P. Mohanmurthy,
R. Mohiuddin
, et al. (31 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project~8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project~8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection of the CRES signal from the conversion electrons of $\mathrm{^{83m}Kr}$ and the first CRES measurement of the beta-decay spectrum of molecular tritium.
△ Less
Submitted 11 March, 2025;
originally announced March 2025.
-
$β$-nuclear-recoil correlation from $^6$He decay in a laser trap
Authors:
P. Müller,
Y. Bagdasarova,
R. Hong,
A. Leredde,
K. G. Bailey,
X. Fléchard,
A. García,
B. Graner,
A. Knecht,
O. Naviliat-Cuncic,
T. P. O'Connor,
M. G. Sternberg,
D. W. Storm,
H. E. Swanson,
F. Wauters,
D. W. Zumwalt
Abstract:
We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for…
▽ More
We report the first precise measurement of a $β$-recoil correlation from a radioactive noble gas ($^6{\rm He}$) confined via a magneto-optical trap. The measurement is motivated by the search for exotic tensor-type contributions to the charged weak current. Interpreted as tensor currents with right-handed neutrinos, the measurements yield: $|C_T/C_A|^2\le 0.022$ (90\% C.L.). On the other hand, for left-handed neutrinos the limits are $0.007< C_T/C_A <0.111$~(90\%\ C.L.). The sensitivity of the present measurement is mainly limited by experimental uncertainties in determining the time response properties and the distance between the atom cloud and the micro-channel plate used for recoil ion detection.
△ Less
Submitted 1 June, 2022;
originally announced June 2022.
-
BLAST: Bridging Length/time scales via Atomistic Simulation Toolkit
Authors:
Henry Chan,
Badri Narayanan,
Mathew Cherukara,
Troy D. Loeffler,
Michael G. Sternberg,
Anthony Avarca,
Subramanian K. R. S. Sankaranarayanan
Abstract:
The ever-increasing power of supercomputers coupled with highly scalable simulation codes have made molecular dynamics an indispensable tool in applications ranging from predictive modeling of materials to computational design and discovery of new materials for a broad range of applications. Multi-fidelity scale bridging between the various flavors of molecular dynamics i.e. ab-initio, classical a…
▽ More
The ever-increasing power of supercomputers coupled with highly scalable simulation codes have made molecular dynamics an indispensable tool in applications ranging from predictive modeling of materials to computational design and discovery of new materials for a broad range of applications. Multi-fidelity scale bridging between the various flavors of molecular dynamics i.e. ab-initio, classical and coarse-grained models has remained a long-standing challenge. Here, we introduce our framework BLAST (Bridging Length/time scales via Atomistic Simulation Toolkit) that leverages machine learning principles to address this challenge. BLAST is a multi-fidelity scale bridging framework that provide users with the capabilities to train and develop their own classical atomistic and coarse-grained interatomic potentials (force fields) for molecular simulations. BLAST is designed to address several long-standing problems in the molecular simulations community, such as unintended misuse of existing force fields due to knowledge gap between developers and users, bottlenecks in traditional force field development approaches, and other issues relating to the accuracy, efficiency, and transferability of force fields. Here, we discuss several important aspects in force field development and highlight features in BLAST that enable its functionalities and ease of use.
△ Less
Submitted 21 February, 2020;
originally announced February 2020.
-
Determining the neutrino mass with Cyclotron Radiation Emission Spectroscopy - Project 8
Authors:
Ali Ashtari Esfahani,
David M. Asner,
Sebastian Böser,
Raphael Cervantes,
Christine Claessens,
Luiz de Viveiros,
Peter J. Doe,
Shepard Doeleman,
Justin L. Fernandes,
Martin Fertl,
Erin C. Finn,
Joseph A. Formaggio,
Daniel Furse,
Mathieu Guigue,
Karsten M. Heeger,
A. Mark Jones,
Kareem Kazkaz,
Jared A. Kofron,
Callum Lamb,
Benjamin H. LaRoque,
Eric Machado,
Elizabeth L. McBride,
Michael L. Miller,
Benjamin Monreal,
Prajwal Mohanmurthy
, et al. (19 additional authors not shown)
Abstract:
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observati…
▽ More
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observations of neutrino oscillations, while the KATRIN Experiment - the current-generation tritium beta-decay experiment that is based on Magnetic Adiabatic Collimation with an Electrostatic (MAC-E) filter - will achieve a sensitivity of $m(ν_e) \lesssim 0.2\,{\rm eV}$. The CRES technique aims to avoid the difficulties in scaling up a MAC-E filter-based experiment to achieve a lower mass sensitivity. In this paper we review the current status of the CRES technique and describe Project 8, a phased absolute neutrino mass experiment that has the potential to reach sensitivities down to $m(ν_e) \lesssim 40\,{\rm meV}$ using an atomic tritium source.
△ Less
Submitted 6 March, 2017;
originally announced March 2017.
-
High accuracy position response calibration method for a micro-channel plate ion detector
Authors:
Ran Hong,
Arnaud Leredde,
Yelena Bagdasarova,
Xavier Flechard,
Alejandro Garcia,
Peter Mueller,
Andreas Knecht,
Etienne Lienard,
Michael Kossin,
Matthew G. Sternberg,
H. E. Swanson,
David W. Zumwalt
Abstract:
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position r…
▽ More
We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~$μ$m and a resolution of 85~$μ$m (FWHM) have been achieved for MeV-scale $α$ particles and ions with energies of $\sim$10~keV. At this level of accuracy, the difference between the MCP position responses to high-energy $α$ particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear $β$-decay experiment.
△ Less
Submitted 8 September, 2016; v1 submitted 27 May, 2016;
originally announced May 2016.
-
Helicity and nuclear $β$ decay correlations
Authors:
Ran Hong,
Matthew G. Sternberg,
Alejandro García
Abstract:
We present simple derivations of nuclear $β$-decay correlations with an emphasis on the special role of helicity. This provides a good opportunity to teach students about helicity and chirality in particle physics through exercises using simple aspects of quantum mechanics. In addition, this paper serves as an introduction to nuclear $β$-decay correlations from both a theoretical and experimental…
▽ More
We present simple derivations of nuclear $β$-decay correlations with an emphasis on the special role of helicity. This provides a good opportunity to teach students about helicity and chirality in particle physics through exercises using simple aspects of quantum mechanics. In addition, this paper serves as an introduction to nuclear $β$-decay correlations from both a theoretical and experimental vantage. This article can be used to introduce students to ongoing experiments searching for hints of new physics in the low-energy precision frontier.
△ Less
Submitted 17 June, 2016; v1 submitted 26 April, 2016;
originally announced April 2016.
-
Single electron detection and spectroscopy via relativistic cyclotron radiation
Authors:
D. M. Asner,
R. F. Bradley,
L. de Viveiros,
P. J. Doe,
J. L. Fernandes,
M. Fertl,
E. C. Finn,
J. A. Formaggio,
D. Furse,
A. M. Jones,
J. N. Kofron,
B. H. LaRoque,
M. Leber,
E. L. McBride,
M. L. Miller,
P. Mohanmurthy,
B. Monreal,
N. S. Oblath,
R. G. H. Robertson,
L. J Rosenberg,
G. Rybka,
D. Rysewyk,
M. G. Sternberg,
J. R. Tedeschi,
T. Thummler
, et al. (2 additional authors not shown)
Abstract:
It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never…
▽ More
It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spec- trometer. We observe the cyclotron radiation emitted by individual magnetically-trapped electrons that are produced with mildly-relativistic energies by a gaseous radioactive source. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta elec- tron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work demonstrates a fundamentally new approach to precision beta spectroscopy for future neutrino mass experiments.
△ Less
Submitted 1 May, 2015; v1 submitted 22 August, 2014;
originally announced August 2014.
-
First Results from the CARIBU Facility: Mass Measurements on the r-Process Path
Authors:
J. Van Schelt,
D. Lascar,
G. Savard,
J. A. Clark,
P. F. Bertone,
S. Caldwell,
A. Chaudhuri,
1 A. F. Levand,
G. Li,
G. E. Morgan,
R. Orford,
R. E. Segel,
K. S. Sharma,
M. G. Sternberg
Abstract:
The Canadian Penning Trap mass spectrometer has made mass measurements of 33 neutron-rich nuclides provided by the new Californium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne National Laboratory. The studied region includes the 132Sn double shell closure and ranges in Z from In to Cs, with Sn isotopes measured out to A = 135, and the typical measurement precision is at the 100 ppb le…
▽ More
The Canadian Penning Trap mass spectrometer has made mass measurements of 33 neutron-rich nuclides provided by the new Californium Rare Isotope Breeder Upgrade (CARIBU) facility at Argonne National Laboratory. The studied region includes the 132Sn double shell closure and ranges in Z from In to Cs, with Sn isotopes measured out to A = 135, and the typical measurement precision is at the 100 ppb level or better. The region encompasses a possible major waiting point of the astrophysical r process, and the impact of the masses on the r process is shown through a series of simulations. These first-ever simulations with direct mass information on this waiting point show significant increases in waiting time at Sn and Sb in comparison with commonly used mass models, demonstrating the inadequacy of existing models for accurate r-process calculations.
△ Less
Submitted 1 July, 2013;
originally announced July 2013.
-
Mass measurements near the $r$-process path using the Canadian Penning Trap mass spectrometer
Authors:
J. Van Schelt,
D. Lascar,
G. Savard,
J. A. Clark,
S. Caldwell,
A. Chaudhuri,
J. Fallis,
J. P. Greene,
A. F. Levand,
G. Li,
K. S. Sharma,
M. G. Sternberg,
T. Sun,
B. J. Zabransky
Abstract:
The masses of 40 neutron-rich nuclides from Z = 51 to 64 were measured at an average precision of $δm/m= 10^{-7}$ using the Canadian Penning Trap mass spectrometer at Argonne National Laboratory. The measurements, of fission fragments from a $^{252}$Cf spontaneous fission source in a helium gas catcher, approach the predicted path of the astrophysical $r$ process. Where overlap exists, this data s…
▽ More
The masses of 40 neutron-rich nuclides from Z = 51 to 64 were measured at an average precision of $δm/m= 10^{-7}$ using the Canadian Penning Trap mass spectrometer at Argonne National Laboratory. The measurements, of fission fragments from a $^{252}$Cf spontaneous fission source in a helium gas catcher, approach the predicted path of the astrophysical $r$ process. Where overlap exists, this data set is largely consistent with previous measurements from Penning traps, storage rings, and reaction energetics, but large systematic deviations are apparent in $β$-endpoint measurements. Differences in mass excess from the 2003 Atomic Mass Evaluation of up to 400 keV are seen, as well as systematic disagreement with various mass models.
△ Less
Submitted 9 April, 2012; v1 submitted 20 March, 2012;
originally announced March 2012.