New plasma regimes with small ELMs and high confinement at the Joint European Torus
Authors:
J. Garcia,
E. de la Luna,
M. Sertoli,
F. Casson,
S. Mazzi,
Z. Stancar,
G. Szepesi,
D. Frigione,
L. Garzotti,
F. Rimini,
D. van Eester,
P. Lomas,
C. Sozzi,
R. N. Aiba,
R. Coelho,
L. Frasinetti,
G. Huijsmans,
F. Liu
Abstract:
New plasma regimes with high confinement, low core impurity accumulation and small Edge localized mode (ELMs) perturbations have been obtained close to ITER conditions in magnetically confined plasmas from the Joint European torus (JET) tokamak. Such regimes are achieved by means of optimized particle fuelling conditions which trigger a self-organize state with a strong increase in rotation and io…
▽ More
New plasma regimes with high confinement, low core impurity accumulation and small Edge localized mode (ELMs) perturbations have been obtained close to ITER conditions in magnetically confined plasmas from the Joint European torus (JET) tokamak. Such regimes are achieved by means of optimized particle fuelling conditions which trigger a self-organize state with a strong increase in rotation and ion temperature and a decrease of the edge density. An interplay between core and edge plasma regions leads to reduced turbulence levels and outward impurity convection. These results pave the way to an attractive alternative to the standard plasmas considered for fusion energy generation in a tokamak with metallic wall environment such as the ones expected in ITER
△ Less
Submitted 8 March, 2021; v1 submitted 3 March, 2021;
originally announced March 2021.
-
Deep Learning for the Analysis of Disruption Precursors based on Plasma Tomography
Authors:
Diogo R. Ferreira,
Pedro J. Carvalho,
Carlo Sozzi,
Peter J. Lomas,
JET Contributors
Abstract:
The JET baseline scenario is being developed to achieve high fusion performance and sustained fusion power. However, with higher plasma current and higher input power, an increase in pulse disruptivity is being observed. Although there is a wide range of possible disruption causes, the present disruptions seem to be closely related to radiative phenomena such as impurity accumulation, core radiati…
▽ More
The JET baseline scenario is being developed to achieve high fusion performance and sustained fusion power. However, with higher plasma current and higher input power, an increase in pulse disruptivity is being observed. Although there is a wide range of possible disruption causes, the present disruptions seem to be closely related to radiative phenomena such as impurity accumulation, core radiation, and radiative collapse. In this work, we focus on bolometer tomography to reconstruct the plasma radiation profile and, on top of it, we apply anomaly detection to identify the radiation patterns that precede major disruptions. The approach makes extensive use of machine learning. First, we train a surrogate model for plasma tomography based on matrix multiplication, which provides a fast method to compute the plasma radiation profiles across the full extent of any given pulse. Then, we train a variational autoencoder to reproduce the radiation profiles by encoding them into a latent distribution and subsequently decoding them. As an anomaly detector, the variational autoencoder struggles to reproduce unusual behaviors, which includes not only the actual disruptions but their precursors as well. These precursors are identified based on an analysis of the anomaly score across all baseline pulses in two recent campaigns at JET.
△ Less
Submitted 8 September, 2020; v1 submitted 6 September, 2020;
originally announced September 2020.
-
Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
A. Curto,
F. Cuttaia,
R. J. Davis,
J. Dick,
M. Frailis,
S. Galeotta,
A. Gregorio,
H. Kurki-Suonio,
C. R. Lawrence,
S. Leach,
J. P. Leahy,
S. Lowe,
D. Maino,
N. Mandolesi,
M. Maris,
E. Martínez-González,
P. R. Meinhold,
G. Morgante,
D. Pearson,
F. Perrotta,
G. Polenta,
T. Poutanen
, et al. (136 additional authors not shown)
Abstract:
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used t…
▽ More
The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.
△ Less
Submitted 19 December, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck Early Results: The Planck mission
Authors:
Planck Collaboration,
P. A. R. Ade,
N. Aghanim,
M. Arnaud,
M. Ashdown,
J. Aumont,
C. Baccigalupi,
M. Baker,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
J. G. Bartlett,
E. Battaner,
K. Benabed,
K. Bennett,
A. Benoît,
J. -P. Bernard,
M. Bersanelli,
R. Bhatia,
J. J. Bock,
A. Bonaldi,
J. R. Bond,
J. Borrill,
F. R. Bouchet,
T. Bradshaw
, et al. (250 additional authors not shown)
Abstract:
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key per…
▽ More
The European Space Agency's Planck satellite was launched on 14 May 2009, and has been surveying the sky stably and continuously since 13 August 2009. Its performance is well in line with expectations, and it will continue to gather scientific data until the end of its cryogenic lifetime. We give an overview of the history of Planck in its first year of operations, and describe some of the key performance aspects of the satellite. This paper is part of a package submitted in conjunction with Planck's Early Release Compact Source Catalogue, the first data product based on Planck to be released publicly. The package describes the scientific performance of the Planck payload, and presents results on a variety of astrophysical topics related to the sources included in the Catalogue, as well as selected topics on diffuse emission.
△ Less
Submitted 16 June, 2011; v1 submitted 11 January, 2011;
originally announced January 2011.
-
Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers
Authors:
F. Villa,
L. Terenzi,
M. Sandri,
P. Meinhold,
T. Poutanen,
P. Battaglia,
C. Franceschet,
N. Hughes,
M. Laaninen,
P. Lapolla,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
M. Frailis,
E. Franceschi,
S. Galeotta,
A. Gregorio,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
L. Mendes,
A. Mennella,
G. Morgante
, et al. (49 additional authors not shown)
Abstract:
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryoge…
▽ More
The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.
△ Less
Submitted 14 May, 2010;
originally announced May 2010.
-
The PLANCK LFI flight model ortho-mode transducers
Authors:
O. D'Arcangelo,
A. Simonetto,
L. Figini,
E. Pagana,
F. Villa,
M. Pecora,
P. Battaglia,
M. Bersanelli,
R. C. Butler,
S. Garavaglia,
P. Guzzi,
N. Mandolesi,
C. Sozzi
Abstract:
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70 GHz. LFI has been calibrated and delivered for integration with the satellite to the European Space Agency on November 2006. The aim of Planck is to measure the anisotropy and polarization of the Cosmic Background Radiation with a sensitivity…
▽ More
The Low Frequency Instrument (LFI) of the ESA Planck CMB mission is an array of 22 ultra sensitive pseudocorrelation radiometers working at 30, 44, and 70 GHz. LFI has been calibrated and delivered for integration with the satellite to the European Space Agency on November 2006. The aim of Planck is to measure the anisotropy and polarization of the Cosmic Background Radiation with a sensitivity and angular resolution never reached before over the full sky. LFI is intrinsically sensitive to polarization thanks to the use of Ortho-Mode Transducers (OMT) located between the feedhorns and the pseudo-correlation radiometers. The OMTs are microwave passive components that divide the incoming radiation into two linear orthogonal components. A set of 11 OMTs (2 at 30 GHz, 3 at 44 GHz, and 6 at 70 GHz) were produced and tested. This work describes the design, development and performance of the eleven Flight Model OMTs of LFI. The final design was reached after several years of development. At first, Elegant Bread Board OMTs were produced to investigate the manufacturing technology and design requirements. Then, a set of 3 Qualification Model (QM) OMTs were designed, manufactured and tested in order to freeze the design and the manufacturing technology for the flight units. Finally, the Flight Models were produced and tested. It is shown that all the OMT units have been accepted for flight and the electromagnetic performance is at least marginally compliant with the requirements. Mechanically, the units passed all the thermoelastic qualification tests after a reworking necessary after the QM campaign.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck LFI flight model feed horns
Authors:
F. Villa,
O. D'Arcangelo,
M. Pecora,
L. Figini,
R. Nesti,
A. Simonetto,
C. Sozzi,
M. Sandri,
P. Battaglia,
P. Guzzi,
M. Bersanelli,
R. C. Butler,
N. Mandolesi
Abstract:
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed horns each connected to the Radiometer Chain Assembly (RCA). This paper describes the design, the manufacturing and the testing of the flight model feed horns.…
▽ More
this paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Low Frequency Instrument is optically interfaced with the ESA Planck telescope through 11 corrugated feed horns each connected to the Radiometer Chain Assembly (RCA). This paper describes the design, the manufacturing and the testing of the flight model feed horns. They have been designed to optimize the LFI optical interfaces taking into account the tight mechanical requirements imposed by the Planck focal plane layout. All the eleven units have been successfully tested and integrated with the Ortho Mode transducers.
△ Less
Submitted 26 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance
Authors:
A. Mennella,
M. Bersanelli,
R. C. Butler,
F. Cuttaia,
O. D'Arcangelo,
R. J. Davis,
M. Frailis,
S. Galeotta,
A. Gregorio,
C. R. Lawrence,
R. Leonardi,
S. R. Lowe,
N. Mandolesi,
M. Maris,
P. Meinhold,
L. Mendes,
G. Morgante,
M. Sandri,
L. Stringhetti,
L. Terenzi,
M. Tomasi,
L. Valenziano,
F. Villa,
A. Zacchei,
A. Zonca
, et al. (61 additional authors not shown)
Abstract:
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise…
▽ More
We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.
△ Less
Submitted 25 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: Design and description of the Low Frequency Instrument
Authors:
M. Bersanelli,
N. Mandolesi,
R. C. Butler,
A. Mennella,
F. Villa,
B. Aja,
E. Artal,
E. Artina,
C. Baccigalupi,
M. Balasini,
G. Baldan,
A. Banday,
P. Bastia,
P. Battaglia,
T. Bernardino,
E. Blackhurst,
L. Boschini,
C. Burigana,
G. Cafagna,
B. Cappellini,
F. Cavaliere,
F. Colombo,
G. Crone,
F. Cuttaia,
O. D'Arcangelo
, et al. (87 additional authors not shown)
Abstract:
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI…
▽ More
In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.
△ Less
Submitted 19 January, 2010;
originally announced January 2010.
-
Planck pre-launch status: the Planck-LFI programme
Authors:
N. Mandolesi,
M. Bersanelli,
R. C. Butler,
E. Artal,
C. Baccigalupi,
A. Balbi,
A. J. Banday,
R. B. Barreiro,
M. Bartelmann,
K. Bennett,
P. Bhandari,
A. Bonaldi,
J. Borrill,
M. Bremer,
C. Burigana,
R. C. Bowman,
P. Cabella,
C. Cantalupo,
B. Cappellini,
T. Courvoisier,
G. Crone,
F. Cuttaia,
L. Danese,
O. D'Arcangelo,
R. D. Davies
, et al. (118 additional authors not shown)
Abstract:
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic…
▽ More
This paper provides an overview of the Low Frequency Instrument (LFI) programme within the ESA Planck mission. The LFI instrument has been developed to produce high precision maps of the microwave sky at frequencies in the range 27-77 GHz, below the peak of the cosmic microwave background (CMB) radiation spectrum. The scientific goals are described, ranging from fundamental cosmology to Galactic and extragalactic astrophysics. The instrument design and development are outlined, together with the model philosophy and testing strategy. The instrument is presented in the context of the Planck mission. The LFI approach to ground and inflight calibration is described. We also describe the LFI ground segment. We present the results of a number of tests demonstrating the capability of the LFI data processing centre (DPC) to properly reduce and analyse LFI flight data, from telemetry information to calibrated and cleaned time ordered data, sky maps at each frequency (in temperature and polarization), component emission maps (CMB and diffuse foregrounds), catalogs for various classes of sources (the Early Release Compact Source Catalogue and the Final Compact Source Catalogue). The organization of the LFI consortium is briefly presented as well as the role of the core team in data analysis and scientific exploitation. All tests carried out on the LFI flight model demonstrate the excellent performance of the instrument and its various subunits. The data analysis pipeline has been tested and its main steps verified. In the first three months after launch, the commissioning, calibration, performance, and verification phases will be completed, after which Planck will begin its operational life, in which LFI will have an integral part.
△ Less
Submitted 15 January, 2010;
originally announced January 2010.
-
The Low Frequency Instrument in the ESA Planck mission
Authors:
A. Mennella,
M. Bersanelli,
B. Cappellini,
D. Maino,
P. Platania,
S. Garavaglia,
R. C. Butler,
N. Mandolesi F. Pasian,
O. D'arcangelo,
A. Simonetto,
C. Sozzi
Abstract:
Measurements of the cosmic microwave background (CMB) allow high precision observation of the cosmic plasma at redshift z~1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy, results from many ground-based and balloon-borne experiments have showed a remarkable consistency between different results and provided quantitative estimates…
▽ More
Measurements of the cosmic microwave background (CMB) allow high precision observation of the cosmic plasma at redshift z~1100. After the success of the NASA satellite COBE, that in 1992 provided the first detection of the CMB anisotropy, results from many ground-based and balloon-borne experiments have showed a remarkable consistency between different results and provided quantitative estimates of fundamental cosmological properties. During the current year the team of the NASA WMAP satellite has released the first improved full-sky maps of the CMB since COBE, leading to a deeper insight in the origin and evolution of the Universe. The ESA satellite Planck, scheduled for launch in 2007, is designed to provide the ultimate measurement of the CMB temperature anisotropy over the full sky, with an accuracy that will be limited only by astrophysical foregrounds, and robust detection of polarisation anisotropy. Planck will observe the sky with two instruments over a wide spectral band (the Low Frequency Instrument, based on coherent radiometers, from 30 to 70 GHz and the High Frequency Instrument, based on bolometric detectors, from 100 to 857 GHz). The mission performances will improve dramatically the scientific return compared to WMAP. Furthermore the LFI radiometers (as well as some of the HFI bolometers) are intrinsically sensitive to polarisation so that by combining the data from different receivers it will be possible to measure accurately the E mode and to detect the B mode of the polarisation power spectrum. Planck sensitivity will offer also the possibility to detect the non-Gaussianities imprinted in the CMB.
△ Less
Submitted 2 October, 2003;
originally announced October 2003.
-
High Performances Corrugated Feed Horns for Space Applications at Millimetre Wavelengths
Authors:
F. Villa,
M. Sandri,
N. Mandolesi,
R. Nesti,
M. Bersanelli,
A. Simonetto,
C. Sozzi,
O. D'Arcangelo,
V. Muzzini,
A. Mennella,
P. Guzzi,
P. Radaelli,
R. Fusi,
E. Alippi
Abstract:
We report on the design, fabrication and testing of a set of high performance corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission. The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70 GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and by electro-f…
▽ More
We report on the design, fabrication and testing of a set of high performance corrugated feed horns at 30 GHz, 70 GHz and 100 GHz, built as advanced prototypes for the Low Frequency Instrument (LFI) of the ESA Planck mission. The electromagnetic designs include linear (100 GHz) and dual shaped (30 and 70 GHz) profiles. Fabrication has been achieved by direct machining at 30 GHz, and by electro-formation at higher frequencies. The measured performances on side lobes and return loss meet the stringent Planck requirements over the large (20%) instrument bandwidth. Moreover, the advantage in terms of main lobe shape and side lobes levels of the dual profiled designs has been demonstrated.
△ Less
Submitted 16 July, 2003;
originally announced July 2003.