-
From Low Field to High Value: Robust Cortical Mapping from Low-Field MRI
Authors:
Karthik Gopinath,
Annabel Sorby-Adams,
Jonathan W. Ramirez,
Dina Zemlyanker,
Jennifer Guo,
David Hunt,
Christine L. Mac Donald,
C. Dirk Keene,
Timothy Coalson,
Matthew F. Glasser,
David Van Essen,
Matthew S. Rosen,
Oula Puonti,
W. Taylor Kimberly,
Juan Eugenio Iglesias
Abstract:
Three-dimensional reconstruction of cortical surfaces from MRI for morphometric analysis is fundamental for understanding brain structure. While high-field MRI (HF-MRI) is standard in research and clinical settings, its limited availability hinders widespread use. Low-field MRI (LF-MRI), particularly portable systems, offers a cost-effective and accessible alternative. However, existing cortical s…
▽ More
Three-dimensional reconstruction of cortical surfaces from MRI for morphometric analysis is fundamental for understanding brain structure. While high-field MRI (HF-MRI) is standard in research and clinical settings, its limited availability hinders widespread use. Low-field MRI (LF-MRI), particularly portable systems, offers a cost-effective and accessible alternative. However, existing cortical surface analysis tools are optimized for high-resolution HF-MRI and struggle with the lower signal-to-noise ratio and resolution of LF-MRI. In this work, we present a machine learning method for 3D reconstruction and analysis of portable LF-MRI across a range of contrasts and resolutions. Our method works "out of the box" without retraining. It uses a 3D U-Net trained on synthetic LF-MRI to predict signed distance functions of cortical surfaces, followed by geometric processing to ensure topological accuracy. We evaluate our method using paired HF/LF-MRI scans of the same subjects, showing that LF-MRI surface reconstruction accuracy depends on acquisition parameters, including contrast type (T1 vs T2), orientation (axial vs isotropic), and resolution. A 3mm isotropic T2-weighted scan acquired in under 4 minutes, yields strong agreement with HF-derived surfaces: surface area correlates at r=0.96, cortical parcellations reach Dice=0.98, and gray matter volume achieves r=0.93. Cortical thickness remains more challenging with correlations up to r=0.70, reflecting the difficulty of sub-mm precision with 3mm voxels. We further validate our method on challenging postmortem LF-MRI, demonstrating its robustness. Our method represents a step toward enabling cortical surface analysis on portable LF-MRI. Code is available at https://surfer.nmr.mgh.harvard.edu/fswiki/ReconAny
△ Less
Submitted 18 May, 2025;
originally announced May 2025.
-
Accelerating Low-field MRI: Compressed Sensing and AI for fast noise-robust imaging
Authors:
Efrat Shimron,
Shanshan Shan,
James Grover,
Neha Koonjoo,
Sheng Shen,
Thomas Boele,
Annabel J. Sorby-Adams,
John E. Kirsch,
Matthew S. Rosen,
David E. J. Waddington
Abstract:
Portable, low-field Magnetic Resonance Imaging (MRI) scanners are increasingly being deployed in clinical settings. However, critical barriers to their widespread use include low signal-to-noise ratio (SNR), generally low image quality, and long scan duration. As these systems can operate in unusual environments, the level and spectral characteristics of the environmental electromagnetic inference…
▽ More
Portable, low-field Magnetic Resonance Imaging (MRI) scanners are increasingly being deployed in clinical settings. However, critical barriers to their widespread use include low signal-to-noise ratio (SNR), generally low image quality, and long scan duration. As these systems can operate in unusual environments, the level and spectral characteristics of the environmental electromagnetic inference (EMI) noise can change substantially across sites and scans, further reducing image quality. Methods for accelerating acquisition and boosting image quality are of critical importance to enable clinically actionable high-quality imaging in these systems. Despite the role that compressed sensing (CS) and artificial intelligence (AI)-based methods have had in improving image quality for high-field MRI, their adoption for low-field imaging is in its infancy, and it is unclear how robust these methods are in low SNR regimes. Here, we investigate and compare leading CS and AI-based methods for image reconstruction from subsampled data and perform a thorough analysis of their performance across a range of SNR values. We compare classical L1-wavelet CS with leading data-driven and model-driven AI methods. Experiments are performed using publicly available datasets and our own low-field and high-field experimental data. Specifically, we apply an unrolled AI network to low-field MRI, and find it outperforms competing reconstruction methods. We prospectively deploy our undersampling methods to accelerate imaging on a 6.5 mT MRI scanner. This work highlights the potential and pitfalls of advanced reconstruction techniques in low-field MRI, paving the way for broader clinical applications.
△ Less
Submitted 10 November, 2024;
originally announced November 2024.
-
P-Count: Persistence-based Counting of White Matter Hyperintensities in Brain MRI
Authors:
Xiaoling Hu,
Annabel Sorby-Adams,
Frederik Barkhof,
W Taylor Kimberly,
Oula Puonti,
Juan Eugenio Iglesias
Abstract:
White matter hyperintensities (WMH) are a hallmark of cerebrovascular disease and multiple sclerosis. Automated WMH segmentation methods enable quantitative analysis via estimation of total lesion load, spatial distribution of lesions, and number of lesions (i.e., number of connected components after thresholding), all of which are correlated with patient outcomes. While the two former measures ca…
▽ More
White matter hyperintensities (WMH) are a hallmark of cerebrovascular disease and multiple sclerosis. Automated WMH segmentation methods enable quantitative analysis via estimation of total lesion load, spatial distribution of lesions, and number of lesions (i.e., number of connected components after thresholding), all of which are correlated with patient outcomes. While the two former measures can generally be estimated robustly, the number of lesions is highly sensitive to noise and segmentation mistakes -- even when small connected components are eroded or disregarded. In this article, we present P-Count, an algebraic WMH counting tool based on persistent homology that accounts for the topological features of WM lesions in a robust manner. Using computational geometry, P-Count takes the persistence of connected components into consideration, effectively filtering out the noisy WMH positives, resulting in a more accurate count of true lesions. We validated P-Count on the ISBI2015 longitudinal lesion segmentation dataset, where it produces significantly more accurate results than direct thresholding.
△ Less
Submitted 20 March, 2024;
originally announced March 2024.
-
PEPSI: Pathology-Enhanced Pulse-Sequence-Invariant Representations for Brain MRI
Authors:
Peirong Liu,
Oula Puonti,
Annabel Sorby-Adams,
William T. Kimberly,
Juan E. Iglesias
Abstract:
Remarkable progress has been made by data-driven machine-learning methods in the analysis of MRI scans. However, most existing MRI analysis approaches are crafted for specific MR pulse sequences (MR contrasts) and usually require nearly isotropic acquisitions. This limits their applicability to diverse real-world clinical data, where scans commonly exhibit variations in appearances due to being ob…
▽ More
Remarkable progress has been made by data-driven machine-learning methods in the analysis of MRI scans. However, most existing MRI analysis approaches are crafted for specific MR pulse sequences (MR contrasts) and usually require nearly isotropic acquisitions. This limits their applicability to diverse real-world clinical data, where scans commonly exhibit variations in appearances due to being obtained with varying sequence parameters, resolutions, and orientations -- especially in the presence of pathology. In this paper, we propose PEPSI, the first pathology-enhanced, and pulse-sequence-invariant feature representation learning model for brain MRI. PEPSI is trained entirely on synthetic images with a novel pathology encoding strategy, and enables co-training across datasets with diverse pathologies and missing modalities. Despite variations in pathology appearances across different MR pulse sequences or the quality of acquired images (e.g., resolution, orientation, artifacts, etc), PEPSI produces a high-resolution image of reference contrast (MP-RAGE) that captures anatomy, along with an image specifically highlighting the pathology. Our experiments demonstrate PEPSI's remarkable capability for image synthesis compared with the state-of-the-art, contrast-agnostic synthesis models, as it accurately reconstructs anatomical structures while differentiating between pathology and normal tissue. We further illustrate the efficiency and effectiveness of PEPSI features for downstream pathology segmentations on five public datasets covering white matter hyperintensities and stroke lesions. Code is available at https://github.com/peirong26/PEPSI.
△ Less
Submitted 10 March, 2024;
originally announced March 2024.
-
Quantifying white matter hyperintensity and brain volumes in heterogeneous clinical and low-field portable MRI
Authors:
Pablo Laso,
Stefano Cerri,
Annabel Sorby-Adams,
Jennifer Guo,
Farrah Mateen,
Philipp Goebl,
Jiaming Wu,
Peirong Liu,
Hongwei Li,
Sean I. Young,
Benjamin Billot,
Oula Puonti,
Gordon Sze,
Sam Payabavash,
Adam DeHavenon,
Kevin N. Sheth,
Matthew S. Rosen,
John Kirsch,
Nicola Strisciuglio,
Jelmer M. Wolterink,
Arman Eshaghi,
Frederik Barkhof,
W. Taylor Kimberly,
Juan Eugenio Iglesias
Abstract:
Brain atrophy and white matter hyperintensity (WMH) are critical neuroimaging features for ascertaining brain injury in cerebrovascular disease and multiple sclerosis. Automated segmentation and quantification is desirable but existing methods require high-resolution MRI with good signal-to-noise ratio (SNR). This precludes application to clinical and low-field portable MRI (pMRI) scans, thus hamp…
▽ More
Brain atrophy and white matter hyperintensity (WMH) are critical neuroimaging features for ascertaining brain injury in cerebrovascular disease and multiple sclerosis. Automated segmentation and quantification is desirable but existing methods require high-resolution MRI with good signal-to-noise ratio (SNR). This precludes application to clinical and low-field portable MRI (pMRI) scans, thus hampering large-scale tracking of atrophy and WMH progression, especially in underserved areas where pMRI has huge potential. Here we present a method that segments white matter hyperintensity and 36 brain regions from scans of any resolution and contrast (including pMRI) without retraining. We show results on eight public datasets and on a private dataset with paired high- and low-field scans (3T and 64mT), where we attain strong correlation between the WMH ($ρ$=.85) and hippocampal volumes (r=.89) estimated at both fields. Our method is publicly available as part of FreeSurfer, at: http://surfer.nmr.mgh.harvard.edu/fswiki/WMH-SynthSeg.
△ Less
Submitted 15 February, 2024; v1 submitted 8 December, 2023;
originally announced December 2023.